SEER2 range15.2–16.8BTU/Wh
HSPF2 range7.8–8.7BTU/Wh
Cooling capacity34,800–36,000BTU/h

Each efficiency range summarizes published EPA records for EL17XP1-036-230A**. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 603 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.8603 / 603
EER2 · BTU/Wh12.2–13.5603 / 603
HSPF2 · BTU/Wh7.8–8.7603 / 603
Cooling capacity · BTU/h34,800–36,000603 / 603
Heating capacity at 47°F / 8.3°C · BTU/h32,400–36,000603 / 603
Heating capacity at 17°F / −8.3°C · BTU/h21,400–24,000603 / 603
Heating capacity at 5°F / −15°C · BTU/h16,800–19,300603 / 603
COP at 5°F / −15°C2.06–2.36603 / 603
Equipment / loop typeHP - Split System603 / 603
Refrigerant / source-reported GWPR-410A (GWP:2088)603 / 603
Compressor stagingSingle stage603 / 603
Connected capabilityNo603 / 603

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CHX35-48B-**-*+TDR+ furnace: ML196UH070XE48B*AHRI reference: 21029354115.407.80178002.18EPA 2462400 →
CHX35-42B-**-*+TDR+ furnace: ML196UH070XE48B*AHRI reference: 21100175915.408.00189002.24EPA 2468798 →
CHX35-42B-**-*+TDR+ furnace: EL297UH045XV36B*AHRI reference: 21319468215.408.10188002.22EPA 2633483 →
CRX35-30/36B-**-*+TDR+ furnace: ML193DF070XE36B*AHRI reference: 21325777415.407.90186002.08EPA 2839493 →
CRX35-30/36B-**-*+TDR+ furnace: ML193DF045XE36B*AHRI reference: 21325777315.407.90187002.12EPA 2839494 →
CRX35-30/36C-**-*+TDR+ furnace: SLP99DF090XV48C*AHRI reference: 21325779115.408.00189002.12EPA 2839530 →
CRX35-30/36C-**-*+TDR+ furnace: SLP99DF090XV60C*AHRI reference: 21325779215.408.00189002.10EPA 2839533 →
CRX35-30/36C-**-*+TDR+ furnace: SLP99DF110XV60C*AHRI reference: 21325779315.408.00189002.08EPA 2839535 →
CRX35-30/36C-**-*+TDR+ furnace: EL297DF090XV60C*AHRI reference: 21331923415.408.00189002.10EPA 2841186 →
CRX35-30/36C-**-*+TDR+ furnace: EL297DF110XV60C*AHRI reference: 21331923515.408.00189002.08EPA 2841188 →
CK40DT-30/36C-0*+TDR+ furnace: EL297DF090XV60C*AHRI reference: 21462257215.408.00189002.10EPA 3474363 →
CK40DT-30/36C-0*+TDR+ furnace: EL297DF110XV60C*AHRI reference: 21462257415.408.00189002.08EPA 3474365 →
CK40DT-30/36C-0*+TDR+ furnace: SLP99DF090XV48C*AHRI reference: 21462258415.408.00189002.12EPA 3474376 →
CK40DT-30/36C-0*+TDR+ furnace: SLP99DF090XV60C*AHRI reference: 21462258515.408.00189002.10EPA 3474377 →
CK40DT-30/36C-0*+TDR+ furnace: SLP99DF110XV60C*AHRI reference: 21462258615.408.00189002.08EPA 3474378 →
CK40HT-42B-0*+TDR+ furnace: EL297UH045XV36B*AHRI reference: 21462242015.408.10188002.22EPA 3475959 →
CK40HT-42B-0*+TDR+ furnace: ML196UH070XE48B*AHRI reference: 21462243315.408.00189002.24EPA 3475970 →
CK40HT-42B-0*+TDR+ furnace: ML296UH045XV36B*AHRI reference: 21462243415.408.10188002.20EPA 3475971 →
CK40HT-48B-0*+TDR+ furnace: ML193UH030XE36B*AHRI reference: 21462250115.407.80176002.18EPA 3476726 →
CK40HT-48B-0*+TDR+ furnace: ML196UH070XE48B*AHRI reference: 21462250615.407.80178002.18EPA 3476753 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.