EL17XP1-036-230A**
ELITE EL17XP1 SERIES · ELITE EL17XP1 Series · Elite EL17XP1 Series · source records, page 21
603 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for EL17XP1-036-230A**. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 603 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16.8 | 603 / 603 |
| EER2 · BTU/Wh | 12.2–13.5 | 603 / 603 |
| HSPF2 · BTU/Wh | 7.8–8.7 | 603 / 603 |
| Cooling capacity · BTU/h | 34,800–36,000 | 603 / 603 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 32,400–36,000 | 603 / 603 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 21,400–24,000 | 603 / 603 |
| Heating capacity at 5°F / −15°C · BTU/h | 16,800–19,300 | 603 / 603 |
| COP at 5°F / −15°C | 2.06–2.36 | 603 / 603 |
| Equipment / loop type | HP - Split System | 603 / 603 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 603 / 603 |
| Compressor staging | Single stage | 603 / 603 |
| Connected capability | No | 603 / 603 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CHX35-48B-**-*+TDR+ furnace: ML180UH090V48B*AHRI reference: 210293535 | 15.80 | 8.00 | 17600 | 2.22 | EPA 2461578 → |
C35-50/60C+TDR+TXV+ furnace: SL280UH110XV60C*AHRI reference: 210293438 | 15.80 | 7.80 | 17400 | 2.10 | EPA 2461581 → |
C35-50/60C+TDR+TXV+ furnace: SL280UH090V60C*AHRI reference: 210293434 | 15.80 | 7.80 | 17400 | 2.08 | EPA 2462078 → |
C35-50/60C+TDR+TXV+ furnace: SL280UH090XV60C*AHRI reference: 210293435 | 15.80 | 7.80 | 17400 | 2.08 | EPA 2462083 → |
CX35-50/60C+TDR+ furnace: SL280UH090V60C*AHRI reference: 210293699 | 15.80 | 7.80 | 17400 | 2.08 | EPA 2462366 → |
CX35-36A+TDR+ furnace: EL180UH040NE36A*AHRI reference: 210293625 | 15.80 | 7.80 | 17000 | 2.08 | EPA 2462386 → |
CHX35-42B-**-*+TDR+ furnace: EL180UH080NE48B*AHRI reference: 211001738 | 15.80 | 8.00 | 18300 | 2.20 | EPA 2468372 → |
CHX35-42B-**-*+TDR+ furnace: EL195UH060NE36B*AHRI reference: 211001739 | 15.80 | 8.00 | 18300 | 2.20 | EPA 2468373 → |
CHX35-42B-**-*+TDR+ furnace: EL196UH030XE36B*AHRI reference: 211001740 | 15.80 | 8.00 | 18500 | 2.24 | EPA 2468374 → |
CHX35-42B-**-*+TDR+ furnace: EL196UH070XE36B*AHRI reference: 211001741 | 15.80 | 8.00 | 18600 | 2.24 | EPA 2468375 → |
CHX35-42B-**-*+TDR+ furnace: ML196UH030XE36B*AHRI reference: 211001757 | 15.80 | 8.00 | 18500 | 2.24 | EPA 2468377 → |
CHX35-42B-**-*+TDR+ furnace: ML193UH045XE36B*AHRI reference: 211001755 | 15.80 | 8.00 | 18600 | 2.24 | EPA 2468799 → |
CHX35-42B-**-*+TDR+ furnace: ML196UH070XE36B*AHRI reference: 211001758 | 15.80 | 8.00 | 18600 | 2.24 | EPA 2468800 → |
CBA25UHE-042-230-**AHRI reference: 212596848 | 15.80 | 8.10 | 17300 | 2.20 | EPA 2633647 → |
CX35-36B+TDR+ furnace: EL297UH070XE36B*AHRI reference: 213630250 | 15.80 | 7.80 | 17200 | 2.06 | EPA 2836278 → |
CRX35-30/36C-**-*+TDR+ furnace: EL297DF090XE48C*AHRI reference: 213630248 | 15.80 | 8.00 | 18600 | 2.14 | EPA 2836290 → |
C35-36B+TDR+TXV+ furnace: EL297UH070XE36B*AHRI reference: 213630242 | 15.80 | 7.80 | 17200 | 2.06 | EPA 2836303 → |
CBA25UHE-036-230-**AHRI reference: 212510942 | 15.80 | 8.00 | 17100 | 2.16 | EPA 2839485 → |
CRX35-30/36B-**-*+TDR+ furnace: ML180DF090E48B*AHRI reference: 213257772 | 15.80 | 8.00 | 18700 | 2.14 | EPA 2839492 → |
CRX35-30/36C-**-*+TDR+ furnace: ML193DF090XE48C*AHRI reference: 213257783 | 15.80 | 8.00 | 18700 | 2.14 | EPA 2839525 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →