Lennox / AIR-SOURCE HEAT PUMP

EL17XP1-036-230A**

ELITE EL17XP1 SERIES · ELITE EL17XP1 Series · Elite EL17XP1 Series · source records, page 13

603 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.8BTU/Wh
HSPF2 range7.8–8.7BTU/Wh
Cooling capacity34,800–36,000BTU/h

Each efficiency range summarizes published EPA records for EL17XP1-036-230A**. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 603 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.8603 / 603
EER2 · BTU/Wh12.2–13.5603 / 603
HSPF2 · BTU/Wh7.8–8.7603 / 603
Cooling capacity · BTU/h34,800–36,000603 / 603
Heating capacity at 47°F / 8.3°C · BTU/h32,400–36,000603 / 603
Heating capacity at 17°F / −8.3°C · BTU/h21,400–24,000603 / 603
Heating capacity at 5°F / −15°C · BTU/h16,800–19,300603 / 603
COP at 5°F / −15°C2.06–2.36603 / 603
Equipment / loop typeHP - Split System603 / 603
Refrigerant / source-reported GWPR-410A (GWP:2088)603 / 603
Compressor stagingSingle stage603 / 603
Connected capabilityNo603 / 603

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CX35-50/60C+TDR+ furnace: ML196UH090XE48C*AHRI reference: 21029369316.207.80172002.12EPA 4431747
CX35-50/60C+TDR+ furnace: ML196UH090XE60C*AHRI reference: 21029369416.207.80172002.12EPA 4431748
CX35-50/60C+TDR+ furnace: ML196UH110XE60C*AHRI reference: 21029369516.207.80172002.12EPA 4431749
CX35-50/60C+TDR+ furnace: EL196UH090XE48C*AHRI reference: 21029367316.207.80172002.12EPA 4431765
CX35-50/60C+TDR+ furnace: EL196UH110XE60C*AHRI reference: 21029367416.207.80172002.12EPA 4431767
CX35-50/60C+TDR+ furnace: ML193UH090XE48C*AHRI reference: 21029368916.207.80172002.14EPA 4431775
CX35-50/60C+TDR+ furnace: ML193UH110XE48C*AHRI reference: 21029369016.207.80170002.12EPA 4431776
C35-50/60C+TDR+TXV+ furnace: EL196UH090XE48C*AHRI reference: 21029340816.207.80172002.12EPA 4431859
C35-50/60C+TDR+TXV+ furnace: EL196UH110XE60C*AHRI reference: 21029340916.207.80172002.12EPA 4431860
C35-50/60C+TDR+TXV+ furnace: ML193UH090XE48C*AHRI reference: 21029342416.207.80172002.14EPA 4431869
C35-50/60C+TDR+TXV+ furnace: ML193UH110XE48C*AHRI reference: 21029342516.207.80170002.12EPA 4431870
C35-50/60C+TDR+TXV+ furnace: ML196UH090XE48C*AHRI reference: 21029342816.207.80172002.12EPA 4431873
C35-50/60C+TDR+TXV+ furnace: ML196UH090XE60C*AHRI reference: 21029342916.207.80172002.12EPA 4431874
C35-50/60C+TDR+TXV+ furnace: ML196UH110XE60C*AHRI reference: 21029343016.207.80172002.12EPA 4431875
CBA27UHE-036-230*+TDRAHRI reference: 21029344616.008.50185002.28EPA 2448444
CHX35-42C-**-*+TDR+ furnace: SLP99UH090XV60C*AHRI reference: 21100180616.008.10184002.18EPA 2454693
CHX35-42B-**-*+TDR+ furnace: ML180UH070E36B*AHRI reference: 21100174916.008.10184002.24EPA 2454755
CHX35-42B-**-*+TDR+ furnace: ML193UH070XE36B*AHRI reference: 21100175616.008.10183002.22EPA 2454758
CHX35-42B-**-*+TDR+ furnace: ML180UH090V48B*AHRI reference: 21100175316.008.10186002.26EPA 2454760
CHX35-42B-**-*+TDR+ furnace: SL280UH090V48B*AHRI reference: 21100176416.008.10186002.26EPA 2454765

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →