Lennox / AIR-SOURCE HEAT PUMP

EL17XP1-030-230A**

ELITE EL17XP1 SERIES · ELITE EL17XP1 Series · Elite EL17XP1 Series · source records, page 3

466 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.2BTU/Wh
HSPF2 range7.8–8.6BTU/Wh
Cooling capacity28,200–30,600BTU/h

Each efficiency range summarizes published EPA records for EL17XP1-030-230A**. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 466 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.2466 / 466
EER2 · BTU/Wh12.2–13.5466 / 466
HSPF2 · BTU/Wh7.8–8.6466 / 466
Cooling capacity · BTU/h28,200–30,600466 / 466
Heating capacity at 47°F / 8.3°C · BTU/h26,600–30,000466 / 466
Heating capacity at 17°F / −8.3°C · BTU/h17,200–19,600466 / 466
Heating capacity at 5°F / −15°C · BTU/h13,200–15,400466 / 466
COP at 5°F / −15°C1.96–2.38466 / 466
Equipment / loop typeHP - Split System466 / 466
Refrigerant / source-reported GWPR-410A (GWP:2088)466 / 466
Compressor stagingSingle stage466 / 466
Connected capabilityNo466 / 466

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CK40CT-36B-0*+TDR+ furnace: EL280UH090XE48B*AHRI reference: 21462238616.208.10141002.28EPA 3475923 →
CK40CT-36B-0*+TDR+ furnace: ML180UH070V36B*AHRI reference: 21462239216.208.10145002.30EPA 3475929 →
CK40CT-36B-0*+TDR+ furnace: ML180UH070V48B*AHRI reference: 21462239316.208.10144002.28EPA 3475930 →
CK40CT-36B-0*+TDR+ furnace: ML180UH090E48B*AHRI reference: 21462239416.208.10141002.26EPA 3475931 →
CK40CT-36B-0*+TDR+ furnace: SL280UH080NV48B*AHRI reference: 21462240516.208.10145002.30EPA 3475939 →
CK40CT-36B-0*+TDR+ furnace: SL280UH090V36B*AHRI reference: 21462240616.208.10145002.30EPA 3475941 →
CK40DT-42B-0*+TDR+ furnace: ML180DF090E48B*AHRI reference: 21462230516.208.60148002.34EPA 3475988 →
CX35-36B+TDR+ furnace: SLP99UH070XV36B*AHRI reference: 21029193916.008.10145002.28EPA 2448446 →
CX35-36B+TDR+ furnace: ML193UH070XE36B*AHRI reference: 21029192616.008.10144002.28EPA 2448470 →
CBA38MV-030-230*+TDRAHRI reference: 21029166116.008.50150002.38EPA 2448527 →
C35-36B+TDR+TXV+ furnace: SL297UH040NV36B*AHRI reference: 21029165616.008.10144002.28EPA 2448531 →
CX35-36B+TDR+ furnace: SL297UH040NV36B*AHRI reference: 21029193716.008.10144002.28EPA 2448533 →
C35-36B+TDR+TXV+ furnace: ML193UH070XE36B*AHRI reference: 21029164516.008.10144002.28EPA 2448538 →
C35-36B+TDR+TXV+ furnace: SLP99UH070XV36B*AHRI reference: 21029165816.008.10145002.28EPA 2448803 →
C35-36B+TDR+TXV+ furnace: ML180UH090V48B*AHRI reference: 21029164216.008.10145002.28EPA 2455267 →
CX35-36A+TDR+ furnace: ML180UH070E36A*AHRI reference: 21029189716.008.10144002.28EPA 2455268 →
C35-36A+TDR+TXV+ furnace: EL280UH070E36A*AHRI reference: 21029160816.008.10143002.26EPA 2455281 →
CX35-36B+TDR+ furnace: SL280UH090V48B*AHRI reference: 21029193616.008.10144002.28EPA 2455300 →
C35-30A+TDR+TXV+ furnace: SL280UH060NV36A*AHRI reference: 21029155516.008.10143002.24EPA 2455329 →
CX35-30B+TDR+ furnace: EL280UH090E48B*AHRI reference: 21029185716.008.00142002.22EPA 2455378 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →