Lennox / AIR-SOURCE HEAT PUMP

EL17XP1-030-230A**

ELITE EL17XP1 SERIES · ELITE EL17XP1 Series · Elite EL17XP1 Series · source records, page 23

466 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.2BTU/Wh
HSPF2 range7.8–8.6BTU/Wh
Cooling capacity28,200–30,600BTU/h

Each efficiency range summarizes published EPA records for EL17XP1-030-230A**. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 466 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.2466 / 466
EER2 · BTU/Wh12.2–13.5466 / 466
HSPF2 · BTU/Wh7.8–8.6466 / 466
Cooling capacity · BTU/h28,200–30,600466 / 466
Heating capacity at 47°F / 8.3°C · BTU/h26,600–30,000466 / 466
Heating capacity at 17°F / −8.3°C · BTU/h17,200–19,600466 / 466
Heating capacity at 5°F / −15°C · BTU/h13,200–15,400466 / 466
COP at 5°F / −15°C1.96–2.38466 / 466
Equipment / loop typeHP - Split System466 / 466
Refrigerant / source-reported GWPR-410A (GWP:2088)466 / 466
Compressor stagingSingle stage466 / 466
Connected capabilityNo466 / 466

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CX35-30B+TDR+ furnace: ML196UH030XE36B*AHRI reference: 21029187415.407.80144002.20EPA 4431795 →
CX35-30B+TDR+ furnace: ML196UH045XE36B*AHRI reference: 21029187515.407.80143002.18EPA 4431797 →
CX35-30B+TDR+ furnace: ML196UH070XE36B*AHRI reference: 21029187615.407.80143002.18EPA 4431798 →
CX35-30B+TDR+ furnace: ML196UH070XE48B*AHRI reference: 21029187715.407.80144002.20EPA 4431800 →
CX35-30B+TDR+ furnace: EL195UH040NE36B*AHRI reference: 21029185015.407.80143002.18EPA 4431801 →
CX35-30B+TDR+ furnace: EL196UH030XE36B*AHRI reference: 21029185215.407.80144002.20EPA 4431802 →
CX35-30B+TDR+ furnace: EL196UH045XE36B*AHRI reference: 21029185315.407.80143002.18EPA 4431804 →
CX35-30B+TDR+ furnace: EL196UH070XE36B*AHRI reference: 21029185515.407.80143002.18EPA 4431805 →
CHX35-30A-**-*+TDR+ furnace: EL180UH040NE36A*AHRI reference: 21029172815.207.80141001.96EPA 2458301 →
CHX35-36C-**-*+TDR+ furnace: SLP99UH110XV60C*AHRI reference: 21029179115.208.50152002.22EPA 2460547 →
CHX35-30A-**-*+TDR+ furnace: EL180UH060NE36A*AHRI reference: 21029172915.207.80141001.96EPA 2461072 →
CX35-30B+TDR+ furnace: EL180UH080NE48B*AHRI reference: 21029184915.208.00147002.16EPA 2462343 →
C35-30B+TDR+TXV+ furnace: EL180UH080NE48B*AHRI reference: 21029156015.208.00147002.16EPA 2462359 →
CHX35-36C-**-*+TDR+ furnace: EL297UH110XV60C*AHRI reference: 21319458115.208.50152002.22EPA 2633677 →
CRX35-42B-**-*+TDR+ furnace: ML296DF045XV36B*AHRI reference: 21325776515.208.50154002.28EPA 2649066 →
CK40HT-30A-0*+TDR+ furnace: EL180UH040NE36A*AHRI reference: 21462220715.207.80141001.96EPA 3475329 →
CK40HT-30A-0*+TDR+ furnace: EL180UH060NE36A*AHRI reference: 21462220815.207.80141001.96EPA 3475331 →
CK40HT-36C-0*+TDR+ furnace: EL297UH110XV60C*AHRI reference: 21462226915.208.50152002.22EPA 3475874 →
CK40HT-36C-0*+TDR+ furnace: SLP99UH110XV60C*AHRI reference: 21462229515.208.50152002.22EPA 3475900 →
CK40DT-42B-0*+TDR+ furnace: ML296DF045XV36B*AHRI reference: 21462231015.208.50154002.28EPA 3476174 →