Lennox / AIR-SOURCE HEAT PUMP

EL17XP1-030-230A**

ELITE EL17XP1 SERIES · ELITE EL17XP1 Series · Elite EL17XP1 Series · source records, page 18

466 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.2BTU/Wh
HSPF2 range7.8–8.6BTU/Wh
Cooling capacity28,200–30,600BTU/h

Each efficiency range summarizes published EPA records for EL17XP1-030-230A**. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 466 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.2466 / 466
EER2 · BTU/Wh12.2–13.5466 / 466
HSPF2 · BTU/Wh7.8–8.6466 / 466
Cooling capacity · BTU/h28,200–30,600466 / 466
Heating capacity at 47°F / 8.3°C · BTU/h26,600–30,000466 / 466
Heating capacity at 17°F / −8.3°C · BTU/h17,200–19,600466 / 466
Heating capacity at 5°F / −15°C · BTU/h13,200–15,400466 / 466
COP at 5°F / −15°C1.96–2.38466 / 466
Equipment / loop typeHP - Split System466 / 466
Refrigerant / source-reported GWPR-410A (GWP:2088)466 / 466
Compressor stagingSingle stage466 / 466
Connected capabilityNo466 / 466

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CK40HT-36C-0*+TDR+ furnace: SLP99UH090XV36C*AHRI reference: 21462229215.608.30147002.22EPA 3475898 →
CK40HT-36C-0*+TDR+ furnace: SLP99UH090XV48C*AHRI reference: 21462229315.608.30144002.22EPA 3475899 →
CK40DT-42B-0*+TDR+ furnace: EL297DF045XE36B*AHRI reference: 21462230015.608.50151002.32EPA 3475907 →
CK40DT-42B-0*+TDR+ furnace: EL297DF045XV36B*AHRI reference: 21462230115.608.60153002.32EPA 3475909 →
CK40CT-36B-0*+TDR+ furnace: EL180UH080NE48B*AHRI reference: 21462237815.608.10146002.24EPA 3475917 →
CK40CT-36B-0*+TDR+ furnace: EL196UH045XE36B*AHRI reference: 21462238215.608.10146002.26EPA 3475919 →
CK40CT-36B-0*+TDR+ furnace: EL196UH070XE36B*AHRI reference: 21462238315.608.10143002.26EPA 3475920 →
CK40CT-36B-0*+TDR+ furnace: EL297UH045XV36B*AHRI reference: 21462238815.608.10145002.26EPA 3475925 →
CK40CT-36B-0*+TDR+ furnace: ML196UH045XE36B*AHRI reference: 21462240015.608.10146002.26EPA 3475936 →
CK40CT-36B-0*+TDR+ furnace: ML196UH070XE36B*AHRI reference: 21462240115.608.10143002.26EPA 3475937 →
CK40CT-36B-0*+TDR+ furnace: ML296UH045XV36B*AHRI reference: 21462240315.608.10144002.22EPA 3475938 →
CK40DT-42B-0*+TDR+ furnace: EL297DF070XE48B*AHRI reference: 21462230215.608.50151002.32EPA 3475982 →
CK40DT-42B-0*+TDR+ furnace: ML196DF070XE48B*AHRI reference: 21462230915.608.60153002.32EPA 3476173 →
CK40DT-42B-0*+TDR+ furnace: ML296DF070XV48B*AHRI reference: 21462231115.608.50153002.32EPA 3476175 →
CK40DT-42B-0*+TDR+ furnace: SL280DF090V48B*AHRI reference: 21462231315.608.60153002.32EPA 3476177 →
CK40DT-42B-0*+TDR+ furnace: SLP99DF070XV36B*AHRI reference: 21462231415.608.60154002.32EPA 3476178 →
CK40CT-30A-0*+TDR+ furnace: EL180UH040NE36A*AHRI reference: 21462231515.607.80142002.20EPA 3476179 →
CK40CT-30A-0*+TDR+ furnace: EL180UH060NE36A*AHRI reference: 21462231615.607.80142002.20EPA 3476180 →
CK40CT-30A-0*+TDR+ furnace: EL280UH070E36A*AHRI reference: 21462231815.608.00144002.20EPA 3476182 →
CK40CT-30A-0*+TDR+ furnace: EL280UH070XE36A*AHRI reference: 21462231915.608.00144002.20EPA 3476183 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →