Lennox / AIR-SOURCE HEAT PUMP

EL17XP1-030-230A**

ELITE EL17XP1 SERIES · ELITE EL17XP1 Series · Elite EL17XP1 Series · source records, page 13

466 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.2BTU/Wh
HSPF2 range7.8–8.6BTU/Wh
Cooling capacity28,200–30,600BTU/h

Each efficiency range summarizes published EPA records for EL17XP1-030-230A**. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 466 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.2466 / 466
EER2 · BTU/Wh12.2–13.5466 / 466
HSPF2 · BTU/Wh7.8–8.6466 / 466
Cooling capacity · BTU/h28,200–30,600466 / 466
Heating capacity at 47°F / 8.3°C · BTU/h26,600–30,000466 / 466
Heating capacity at 17°F / −8.3°C · BTU/h17,200–19,600466 / 466
Heating capacity at 5°F / −15°C · BTU/h13,200–15,400466 / 466
COP at 5°F / −15°C1.96–2.38466 / 466
Equipment / loop typeHP - Split System466 / 466
Refrigerant / source-reported GWPR-410A (GWP:2088)466 / 466
Compressor stagingSingle stage466 / 466
Connected capabilityNo466 / 466

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
C35-30A+TDR+TXV+ furnace: EL280UH070XE36A*AHRI reference: 21029154715.608.00144002.20EPA 2455414 →
CX35-30A+TDR+ furnace: EL180UH040NE36A*AHRI reference: 21029183115.607.80142002.20EPA 2455466 →
CHX35-36C-**-*+TDR+ furnace: ML193UH090XE36C*AHRI reference: 21029176615.608.30147002.24EPA 2455477 →
CHX35-30A-**-*+TDR+ furnace: SL280UH070XV36A*AHRI reference: 21029174415.607.80139001.98EPA 2458028 →
CX35-30B+TDR+ furnace: ML180UH090V48B*AHRI reference: 21029186915.608.00145002.18EPA 2458308 →
CX35-30A+TDR+ furnace: ML180UH070E36A*AHRI reference: 21029184215.608.00144002.20EPA 2460039 →
CHX35-36C-**-*+TDR+ furnace: SLP99UH090XV48C*AHRI reference: 21029178915.608.30144002.22EPA 2460546 →
C35-30A+TDR+TXV+ furnace: SL280UH070V36A*AHRI reference: 21029155615.608.00145002.20EPA 2460553 →
CX35-30A+TDR+ furnace: SL280UH070V36A*AHRI reference: 21029184615.608.00145002.20EPA 2460560 →
CHX35-36C-**-*+TDR+ furnace: EL280UH110E60C*AHRI reference: 21029175215.608.50148002.22EPA 2460562 →
CHX35-30A-**-*+TDR+ furnace: ML180UH030V36A*AHRI reference: 21029173315.607.80139002.00EPA 2460565 →
CHX35-36C-**-*+TDR+ furnace: ML180UH110E60C*AHRI reference: 21029176315.608.30146002.22EPA 2460574 →
CHX35-36C-**-*+TDR+ furnace: ML196UH090XE48C*AHRI reference: 21029177215.608.30145002.22EPA 2460818 →
CHX35-36C-**-*+TDR+ furnace: SL297UH080NV48C*AHRI reference: 21029178515.608.30146002.20EPA 2460862 →
CX35-36B+TDR+ furnace: EL180UH080NE48B*AHRI reference: 21029190315.608.10146002.24EPA 2460889 →
CHX35-36C-**-*+TDR+ furnace: SL280UH080NV60C*AHRI reference: 21029177815.608.50150002.24EPA 2460903 →
CHX35-36C-**-*+TDR+ furnace: EL196UH090XE48C*AHRI reference: 21029174815.608.30145002.22EPA 2461073 →
C35-30B+TDR+TXV+ furnace: ML180UH090V48B*AHRI reference: 21029158315.608.00145002.18EPA 2461077 →
C35-30A+TDR+TXV+ furnace: ML180UH070V36A*AHRI reference: 21029155215.608.00145002.20EPA 2461079 →
CHX35-36C-**-*+TDR+ furnace: ML193UH090XE48C*AHRI reference: 21029176715.608.30146002.24EPA 2461083 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →