EL17XP1-030-230A**
ELITE EL17XP1 SERIES · ELITE EL17XP1 Series · Elite EL17XP1 Series
466 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for EL17XP1-030-230A**. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 466 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16.2 | 466 / 466 |
| EER2 · BTU/Wh | 12.2–13.5 | 466 / 466 |
| HSPF2 · BTU/Wh | 7.8–8.6 | 466 / 466 |
| Cooling capacity · BTU/h | 28,200–30,600 | 466 / 466 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 26,600–30,000 | 466 / 466 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 17,200–19,600 | 466 / 466 |
| Heating capacity at 5°F / −15°C · BTU/h | 13,200–15,400 | 466 / 466 |
| COP at 5°F / −15°C | 1.96–2.38 | 466 / 466 |
| Equipment / loop type | HP - Split System | 466 / 466 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 466 / 466 |
| Compressor staging | Single stage | 466 / 466 |
| Connected capability | No | 466 / 466 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CX35-36B+TDR+ furnace: ML180UH070V48B*AHRI reference: 210291921 | 16.20 | 8.10 | 14400 | 2.28 | EPA 2455235 → |
C35-36B+TDR+TXV+ furnace: ML180UH070V36B*AHRI reference: 210291639 | 16.20 | 8.10 | 14500 | 2.30 | EPA 2455284 → |
CX35-36B+TDR+ furnace: SL280UH080NV48B*AHRI reference: 210291934 | 16.20 | 8.10 | 14500 | 2.30 | EPA 2455311 → |
CX35-36B+TDR+ furnace: EL280UH090E36B*AHRI reference: 210291910 | 16.20 | 8.10 | 14300 | 2.30 | EPA 2455354 → |
C35-36B+TDR+TXV+ furnace: ML180UH090E48B*AHRI reference: 210291641 | 16.20 | 8.10 | 14100 | 2.26 | EPA 2455374 → |
C35-36B+TDR+TXV+ furnace: ML180UH070V48B*AHRI reference: 210291640 | 16.20 | 8.10 | 14400 | 2.28 | EPA 2455376 → |
C35-36B+TDR+TXV+ furnace: SL280UH080NV48B*AHRI reference: 210291652 | 16.20 | 8.10 | 14500 | 2.30 | EPA 2455427 → |
CX35-36B+TDR+ furnace: SL280UH090V36B*AHRI reference: 210291935 | 16.20 | 8.10 | 14500 | 2.30 | EPA 2458310 → |
CX35-36A+TDR+ furnace: SL280UH060NV36A*AHRI reference: 210291900 | 16.20 | 8.10 | 14500 | 2.30 | EPA 2460059 → |
CX35-36B+TDR+ furnace: EL280UH090XE48B*AHRI reference: 210291913 | 16.20 | 8.10 | 14100 | 2.28 | EPA 2460877 → |
C35-36A+TDR+TXV+ furnace: SL280UH060NV36A*AHRI reference: 210291618 | 16.20 | 8.10 | 14500 | 2.30 | EPA 2461065 → |
CX35-36B+TDR+ furnace: ML180UH090E48B*AHRI reference: 210291922 | 16.20 | 8.10 | 14100 | 2.26 | EPA 2461093 → |
CX35-36B+TDR+ furnace: EL280UH090E48B*AHRI reference: 210291911 | 16.20 | 8.10 | 14100 | 2.28 | EPA 2461094 → |
C35-36B+TDR+TXV+ furnace: EL280UH090E36B*AHRI reference: 210291629 | 16.20 | 8.10 | 14300 | 2.30 | EPA 2461356 → |
CX35-36B+TDR+ furnace: ML180UH070V36B*AHRI reference: 210291920 | 16.20 | 8.10 | 14500 | 2.30 | EPA 2462060 → |
C35-36B+TDR+TXV+ furnace: EL280UH090E48B*AHRI reference: 210291630 | 16.20 | 8.10 | 14100 | 2.28 | EPA 2462352 → |
C35-36B+TDR+TXV+ furnace: EL280UH090XE48B*AHRI reference: 210291631 | 16.20 | 8.10 | 14100 | 2.28 | EPA 2462357 → |
C35-36B+TDR+TXV+ furnace: SL280UH090V36B*AHRI reference: 210291653 | 16.20 | 8.10 | 14500 | 2.30 | EPA 2462369 → |
CHX35-30B-**-*+TDR+ furnace: ML180UH070V36B*AHRI reference: 212442671 | 16.20 | 8.00 | 13700 | 2.10 | EPA 2474866 → |
CHX35-30B-**-*+TDR+ furnace: ML180UH070E36B*AHRI reference: 212442670 | 16.20 | 7.80 | 13400 | 2.12 | EPA 2474867 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →