Lennox / AIR-SOURCE HEAT PUMP

EL17XP1-018-230A**

EL17XP1 SERIES · ELITE EL17XP1 SERIES · ELITE EL17XP1 Series · source records, page 7

480 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.8BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity17,800–18,000BTU/h

Each efficiency range summarizes published EPA records for EL17XP1-018-230A**. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 480 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.8480 / 480
EER2 · BTU/Wh12.2–14480 / 480
HSPF2 · BTU/Wh7.8–8.5480 / 480
Cooling capacity · BTU/h17,800–18,000480 / 480
Heating capacity at 47°F / 8.3°C · BTU/h16,000–18,000480 / 480
Heating capacity at 17°F / −8.3°C · BTU/h10,200–12,100480 / 480
Heating capacity at 5°F / −15°C · BTU/h7,500–9,700480 / 480
COP at 5°F / −15°C1.9–2.16480 / 480
Equipment / loop typeHP - Split System480 / 480
Refrigerant / source-reported GWPR-410A (GWP:2088)480 / 480
Compressor stagingSingle stage480 / 480
Connected capabilityNo480 / 480

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CX35-30A+TDR+ furnace: ML180UH070V36A*AHRI reference: 21029055816.407.8077002.00EPA 2455261
CX35-30B+TDR+ furnace: ML196UH045XE36B*AHRI reference: 21029062416.407.8077001.98EPA 2455278
CHX35-30B-**-*+TDR+ furnace: SL280UH090V48B*AHRI reference: 21028897616.408.0080002.00EPA 2455283
CHX35-24B-**-*+TDR+ furnace: ML180UH070E36B*AHRI reference: 21028892716.408.1082002.10EPA 2455315
C35-30B+TDR+TXV+ furnace: ML196UH045XE36B*AHRI reference: 21028880616.407.8077001.98EPA 2455322
C35-30B+TDR+TXV+ furnace: SL280UH090V48B*AHRI reference: 21028881316.408.0080001.96EPA 2455323
CX35-30B+TDR+ furnace: EL196UH045XE36B*AHRI reference: 21029057816.407.8077001.98EPA 2455357
C35-24B+TDR+TXV+ furnace: ML180UH070E36B*AHRI reference: 21028875116.408.0082002.10EPA 2455360
C35-24B+TDR+TXV+ furnace: SL280UH090V36B*AHRI reference: 21028876616.408.1086002.10EPA 2455361
C35-30A+TDR+TXV+ furnace: ML180UH070E36A*AHRI reference: 21028877916.407.8077001.98EPA 2455641
C35-24B+TDR+TXV+ furnace: SLP99UH070XV36B*AHRI reference: 21028877016.408.1084002.08EPA 2457562
C35-24A+TDR+TXV+ furnace: EL280UH070E36A*AHRI reference: 21028872716.408.1082002.12EPA 2457564
CHX35-30B-**-*+TDR+ furnace: ML296UH045XV36B*AHRI reference: 21028897216.408.0078001.96EPA 2457573
CX35-30A+TDR+ furnace: ML180UH070XE36A*AHRI reference: 21029056016.407.8077001.98EPA 2457578
CHX35-24B-**-*+TDR+ furnace: ML180UH070V48B*AHRI reference: 21028892916.408.1087002.10EPA 2457582
CHX35-24A-**-*+TDR+ furnace: ML180UH030V36A*AHRI reference: 21028890516.408.1080002.08EPA 2459824
CHX35-24A-**-*+TDR+ furnace: EL280UH070E36A*AHRI reference: 21028890316.408.1082002.06EPA 2459828
CX35-24A+TDR+ furnace: EL280UH070E36A*AHRI reference: 21028901816.408.1082002.12EPA 2459830
CHX35-24A-**-*+TDR+ furnace: ML180UH045V36A*AHRI reference: 21028890716.408.1080002.08EPA 2459833
CHX35-24A-**-*+TDR+ furnace: ML180UH070V36A*AHRI reference: 21028890916.408.0080002.06EPA 2459839

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →