Lennox / AIR-SOURCE HEAT PUMP

EL17XP1-018-230A**

EL17XP1 SERIES · ELITE EL17XP1 SERIES · ELITE EL17XP1 Series · source records, page 14

480 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.8BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity17,800–18,000BTU/h

Each efficiency range summarizes published EPA records for EL17XP1-018-230A**. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 480 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.8480 / 480
EER2 · BTU/Wh12.2–14480 / 480
HSPF2 · BTU/Wh7.8–8.5480 / 480
Cooling capacity · BTU/h17,800–18,000480 / 480
Heating capacity at 47°F / 8.3°C · BTU/h16,000–18,000480 / 480
Heating capacity at 17°F / −8.3°C · BTU/h10,200–12,100480 / 480
Heating capacity at 5°F / −15°C · BTU/h7,500–9,700480 / 480
COP at 5°F / −15°C1.9–2.16480 / 480
Equipment / loop typeHP - Split System480 / 480
Refrigerant / source-reported GWPR-410A (GWP:2088)480 / 480
Compressor stagingSingle stage480 / 480
Connected capabilityNo480 / 480

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CK40CT-24A-0*+TDR+ furnace: ML180UH070E36A*AHRI reference: 21462193316.408.0082002.10EPA 3474735 →
CK40CT-24A-0*+TDR+ furnace: ML180UH070V36A*AHRI reference: 21462193416.408.0082002.10EPA 3474736 →
CK40CT-24A-0*+TDR+ furnace: ML180UH070XE36A*AHRI reference: 21462193516.408.0082002.10EPA 3474737 →
CK40HT-24B-0*+TDR+ furnace: EL296UH045XE36B*AHRI reference: 21572804816.408.1082002.08EPA 3649706 →
CK40HT-24B-0*+TDR+ furnace: EL296UH045XV36B*AHRI reference: 21572804916.408.1084002.06EPA 3649707 →
CK40HT-24B-0*+TDR+ furnace: EL296UH070XV36B*AHRI reference: 21572805116.408.1084002.10EPA 3649709 →
CK40HT-30B-0*+TDR+ furnace: EL296UH070XE36B*AHRI reference: 21572805416.407.8077002.00EPA 3649712 →
CK40CT-24B-0*+TDR+ furnace: EL296UH070XV36B*AHRI reference: 21572806416.408.1084002.08EPA 3649722 →
CK40CT-30B-0*+TDR+ furnace: EL296UH045XE36B*AHRI reference: 21572806516.407.8077001.98EPA 3649723 →
CK40CT-30B-0*+TDR+ furnace: EL296UH045XV36B*AHRI reference: 21572806616.408.0078002.00EPA 3649724 →
CK40CT-30B-0*+TDR+ furnace: EL296UH070XE36B*AHRI reference: 21572806716.407.8081001.96EPA 3649725 →
CX35-24B+TDR+ furnace: ML193UH070XE36B*AHRI reference: 21028904916.208.1082002.10EPA 2460308 →
C35-24A+TDR+TXV+ furnace: ML180UH045E36A*AHRI reference: 21028873016.208.0082002.08EPA 2461317 →
CX35-24A+TDR+ furnace: ML180UH045E36A*AHRI reference: 21028902116.208.0082002.08EPA 2462011 →
C35-24B+TDR+TXV+ furnace: ML193UH070XE36B*AHRI reference: 21028875816.208.1082002.10EPA 2462313 →
CBA27UHE-024-230*+TDRAHRI reference: 21180697116.208.1082002.16EPA 2467997 →
CRX35-30/36B-**-*+TDR+ furnace: SLP99DF070XV36B*AHRI reference: 21325772716.208.5091002.08EPA 2649261 →
CRX35-30/36B-**-*+TDR+ furnace: ML196DF070XE48B*AHRI reference: 21325772216.208.4090002.08EPA 2649299 →
CRX35-30/36B-**-*+TDR+ furnace: EL297DF045XV36B*AHRI reference: 21331922816.208.5091002.08EPA 2841180 →
C35-24B+TDR+TXV+ furnace: EL297UH045XE36B*AHRI reference: 21343418116.208.0082002.06EPA 2842205 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →