Lennox / AIR-SOURCE HEAT PUMP

EL16KP1-036-230A**

ELITE EL16KP1 Series · Elite EL16KP1 SERIES · source records, page 3

69 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8BTU/Wh
Cooling capacity35,400–36,000BTU/h

Each efficiency range summarizes published EPA records for EL16KP1-036-230A**. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 69 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–1669 / 69
EER2 · BTU/Wh12.5–13.469 / 69
HSPF2 · BTU/Wh7.8–869 / 69
Cooling capacity · BTU/h35,400–36,00069 / 69
Heating capacity at 47°F / 8.3°C · BTU/h31,400–35,60069 / 69
Heating capacity at 17°F / −8.3°C · BTU/h20,000–21,20069 / 69
Heating capacity at 5°F / −15°C · BTU/h15,700–16,90069 / 69
COP at 5°F / −15°C1.9–2.0669 / 69
Equipment / loop typeHP - Split System69 / 69
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)69 / 69
Compressor stagingSingle stage69 / 69
Connected capabilityNo69 / 69

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CK40HT-42C-**+TDR+ furnace: ML193UH110XE48C*AHRI reference: 21573973415.507.80164001.96EPA 3652473 →
CK40HT-42C-**+TDR+ furnace: ML193UH110XE60C*AHRI reference: 21573973515.507.80168001.98EPA 3652474 →
CK40HT-42C-**+TDR+ furnace: ML196UH090XE60C*AHRI reference: 21573973815.507.80168001.98EPA 3652475 →
CK40HT-42C-**+TDR+ furnace: ML196UH090XE48C*AHRI reference: 21573973715.507.80167001.96EPA 3652476 →
CK40HT-42C-**+TDR+ furnace: ML296UH110XV60C*AHRI reference: 21573974115.507.80165001.96EPA 3652477 →
CK40HT-42C-**+TDR+ furnace: SL280UH080NV60C*AHRI reference: 21573974215.507.80166001.98EPA 3652478 →
CK40HT-42C-**+TDR+ furnace: SL280UH090V60C*AHRI reference: 21573974315.507.80167001.98EPA 3652479 →
CK40HT-42C-**+TDR+ furnace: SL280UH090XV60C*AHRI reference: 21573974415.507.80167001.98EPA 3652480 →
CK40HT-42C-**+TDR+ furnace: SL280UH100NV60C*AHRI reference: 21573974515.507.80168001.98EPA 3652481 →
CK40HT-42C-**+TDR+ furnace: SLP99UH110XV60C*AHRI reference: 21573975115.507.80167001.96EPA 3652483 →
CK40[C,U]T-48C-**+TDR+ furnace: EL297UH110XV60C*AHRI reference: 21573975715.507.80168002.00EPA 3652485 →
CK40[C,U]T-48C-**+TDR+ furnace: EL297UH110XV48C*AHRI reference: 21573975615.507.80166001.98EPA 3652486 →
CK40[C,U]T-48C-**+TDR+ furnace: ML193UH090XE48C*AHRI reference: 21573966315.507.80167002.00EPA 4512855 →
CK40[C,U]T-48C-**+TDR+ furnace: ML196UH090XE48C*AHRI reference: 21573966715.507.80168002.00EPA 4512856 →
CK40HT-42C-**+TDR+ furnace: ML297UH090XV36C*AHRI reference: 21869586415.507.80166001.94EPA 4691612 →
CK40[C,U]T-48C-**+TDR+ furnace: ML297UH090XV36C*AHRI reference: 21869585115.507.80166001.96EPA 4691613 →
CK40[C,U]T-48C-**+TDR+ furnace: EL195UH100NE60C*AHRI reference: 21573964515.207.80168001.98EPA 3652426 →
CK40[C,U]T-48C-**+TDR+ furnace: EL296UH090XV60C*AHRI reference: 21573965415.207.80168001.98EPA 3652430 →
CK40[C,U]T-48C-**+TDR+ furnace: SLP99UH090XV60C*AHRI reference: 21573967915.207.80169001.98EPA 3652443 →
CK40HT-42B-**+TDR+ furnace: SLP99UH070XV36B*AHRI reference: 21573971215.207.80168001.96EPA 3652455 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →