Lennox / AIR-SOURCE HEAT PUMP

EL16KP1-024-230A**

ELITE EL16KP1 Series · Elite EL16KP1 SERIES · source records, page 9

179 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.2BTU/Wh
Cooling capacity22,800–24,000BTU/h

Each efficiency range summarizes published EPA records for EL16KP1-024-230A**. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 179 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16179 / 179
EER2 · BTU/Wh12–13.8179 / 179
HSPF2 · BTU/Wh7.8–8.2179 / 179
Cooling capacity · BTU/h22,800–24,000179 / 179
Heating capacity at 47°F / 8.3°C · BTU/h20,400–23,000179 / 179
Heating capacity at 17°F / −8.3°C · BTU/h12,900–14,700179 / 179
Heating capacity at 5°F / −15°C · BTU/h10,500–11,600179 / 179
COP at 5°F / −15°C1.96–2.2179 / 179
Equipment / loop typeHP - Split System179 / 179
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)179 / 179
Compressor stagingSingle stage179 / 179
Connected capabilityNo179 / 179

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CK40HT-30B-**+TDR+ furnace: ML196UH070XE48B*AHRI reference: 21571055915.207.80112002.04EPA 3647070
CK40HT-30B-**+TDR+ furnace: SL280UH080NV48B*AHRI reference: 21571056215.207.80110002.04EPA 3647072
CK40HT-30B-**+TDR+ furnace: SL297UH040NV36B*AHRI reference: 21571056515.207.80110002.04EPA 3647076
CK40DT-30/36B-**+TDR+ furnace: EL280DF090E48B*AHRI reference: 21571056815.208.20114002.10EPA 3647079
CK40DT-30/36B-**+TDR+ furnace: ML180DF090E48B*AHRI reference: 21571057415.208.20113002.10EPA 3647080
CK40DT-30/36C-**+TDR+ furnace: EL297DF090XE48C*AHRI reference: 21571058215.208.20113002.10EPA 3647081
CBK45UHET-024-230-**AHRI reference: 21571035915.207.80110002.06EPA 3647103
CBK47UHET-024-230-**AHRI reference: 21571036415.208.20112002.16EPA 3647105
CBK48MVT-018/024-230-**AHRI reference: 21571036615.208.20112002.16EPA 3647107
CK40[C,U]T-24A-**+TDR+ furnace: EL180UH040NE36A*AHRI reference: 21571036815.207.80110002.02EPA 3647109
CK40[C,U]T-24A-**+TDR+ furnace: EL180UH060NE36A*AHRI reference: 21571036915.207.80110002.02EPA 3647110
CK40[C,U]T-24A-**+TDR+ furnace: EL280UH070E36A*AHRI reference: 21571037115.207.80110002.02EPA 3647112
CK40[C,U]T-24A-**+TDR+ furnace: SL280UH070XV36A*AHRI reference: 21571038215.207.80110002.02EPA 3647121
CK40[C,U]T-24B-**+TDR+ furnace: EL196UH030XE36B*AHRI reference: 21571038615.207.80107002.00EPA 3647122
CK40[C,U]T-24B-**+TDR+ furnace: EL280UH090E36B*AHRI reference: 21571038915.207.80110002.02EPA 3647123
CBK43UHET-030-DV-**AHRI reference: 21833083815.207.80110002.04EPA 4585354
CBK43UHET-018-DV-**AHRI reference: 21833083615.207.80106002.04EPA 4585355
CK40HT-24B-**+TDR+ furnace: ML297UH070XV36B*AHRI reference: 21869102215.208.00110002.04EPA 4679303
CK40HT-24B-**+TDR+ furnace: ML297UH045XV36B*AHRI reference: 21869101315.208.00109002.02EPA 4679306

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →