Lennox / AIR-SOURCE HEAT PUMP

EL16KP1-024-230A**

ELITE EL16KP1 Series · Elite EL16KP1 SERIES · source records, page 5

179 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.2BTU/Wh
Cooling capacity22,800–24,000BTU/h

Each efficiency range summarizes published EPA records for EL16KP1-024-230A**. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 179 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16179 / 179
EER2 · BTU/Wh12–13.8179 / 179
HSPF2 · BTU/Wh7.8–8.2179 / 179
Cooling capacity · BTU/h22,800–24,000179 / 179
Heating capacity at 47°F / 8.3°C · BTU/h20,400–23,000179 / 179
Heating capacity at 17°F / −8.3°C · BTU/h12,900–14,700179 / 179
Heating capacity at 5°F / −15°C · BTU/h10,500–11,600179 / 179
COP at 5°F / −15°C1.96–2.2179 / 179
Equipment / loop typeHP - Split System179 / 179
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)179 / 179
Compressor stagingSingle stage179 / 179
Connected capabilityNo179 / 179

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CK40[C,U]T-24A-**+TDR+ furnace: ML180UH045V36A*AHRI reference: 21571037515.507.80107002.02EPA 3647114
CK40[C,U]T-24A-**+TDR+ furnace: ML180UH045XE36A*AHRI reference: 21571037615.507.80106002.00EPA 3647115
CK40[C,U]T-24A-**+TDR+ furnace: ML180UH070E36A*AHRI reference: 21571037715.507.80108002.04EPA 3647116
CK40[C,U]T-24A-**+TDR+ furnace: ML180UH070V36A*AHRI reference: 21571037815.507.80108002.04EPA 3647117
CK40[C,U]T-24A-**+TDR+ furnace: ML180UH070XE36A*AHRI reference: 21571037915.507.80108002.04EPA 3647118
CK40[C,U]T-24A-**+TDR+ furnace: SL280UH060NV36A*AHRI reference: 21571038015.507.80108002.02EPA 3647119
CK40[C,U]T-24A-**+TDR+ furnace: SL280UH070V36A*AHRI reference: 21571038115.507.80109002.04EPA 3647120
CK40[C,U]T-24B-**+TDR+ furnace: EL280UH090E48B*AHRI reference: 21571039015.508.00109002.04EPA 3647124
CK40HT-30B-**+TDR+ furnace: ML297UH070XV36B*AHRI reference: 21869102315.508.00110002.06EPA 4679302
CK40[C,U]T-30B-**+TDR+ furnace: ML297UH070XV36B*AHRI reference: 21869101915.508.00115002.16EPA 4679304
CK40HT-30B-**+TDR+ furnace: ML297UH045XV36B*AHRI reference: 21869101415.507.80107002.02EPA 4679305
CK40[C,U]T-30B-**+TDR+ furnace: ML297UH045XV36B*AHRI reference: 21869101215.508.00113002.12EPA 4679307
CK40[C,U]T-24B-**+TDR+ furnace: ML297UH045XV36B*AHRI reference: 21869101115.507.80107002.00EPA 4679308
CK40[C,U]T-24B-**+TDR+ furnace: EL297UH045XV36B*AHRI reference: 21571039315.207.80109002.02EPA 3646923
CK40[C,U]T-24B-**+TDR+ furnace: ML180UH090V48B*AHRI reference: 21571040115.207.80110002.02EPA 3646930
CK40[C,U]T-24B-**+TDR+ furnace: ML193UH045XE36B*AHRI reference: 21571040415.207.80110002.02EPA 3646933
CK40[C,U]T-24B-**+TDR+ furnace: ML196UH030XE36B*AHRI reference: 21571040615.207.80107001.98EPA 3646934
CK40[C,U]T-24B-**+TDR+ furnace: ML193UH070XE36B*AHRI reference: 21571040515.207.80110002.04EPA 3646935
CK40[C,U]T-24B-**+TDR+ furnace: ML196UH070XE36B*AHRI reference: 21571040815.207.80110002.04EPA 3646936
CK40[C,U]T-24B-**+TDR+ furnace: SL280UH080NV48B*AHRI reference: 21571041215.207.80109002.00EPA 3646938

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →