EL16KP1-024-230A**
ELITE EL16KP1 Series · Elite EL16KP1 SERIES · source records, page 3
179 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for EL16KP1-024-230A**. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 179 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 179 / 179 |
| EER2 · BTU/Wh | 12–13.8 | 179 / 179 |
| HSPF2 · BTU/Wh | 7.8–8.2 | 179 / 179 |
| Cooling capacity · BTU/h | 22,800–24,000 | 179 / 179 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 20,400–23,000 | 179 / 179 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 12,900–14,700 | 179 / 179 |
| Heating capacity at 5°F / −15°C · BTU/h | 10,500–11,600 | 179 / 179 |
| COP at 5°F / −15°C | 1.96–2.2 | 179 / 179 |
| Equipment / loop type | HP - Split System | 179 / 179 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 179 / 179 |
| Compressor staging | Single stage | 179 / 179 |
| Connected capability | No | 179 / 179 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CK40[C,U]T-30B-**+TDR+ furnace: SLP99UH070XV36B*AHRI reference: 215710467 | 15.50 | 8.00 | 11300 | 2.14 | EPA 3647000 → |
CK40HT-24A-**+TDR+ furnace: EL280UH045E36A*AHRI reference: 215710470 | 15.50 | 7.80 | 10500 | 1.96 | EPA 3647001 → |
CK40HT-24A-**+TDR+ furnace: ML180UH045V36A*AHRI reference: 215710475 | 15.50 | 7.80 | 10600 | 1.96 | EPA 3647003 → |
CK40HT-24A-**+TDR+ furnace: ML180UH070V36A*AHRI reference: 215710478 | 15.50 | 7.80 | 10600 | 1.96 | EPA 3647005 → |
CK40HT-24B-**+TDR+ furnace: EL280UH090E48B*AHRI reference: 215710490 | 15.50 | 8.10 | 10800 | 2.02 | EPA 3647013 → |
CK40HT-24B-**+TDR+ furnace: EL280UH090XE48B*AHRI reference: 215710491 | 15.50 | 8.10 | 10700 | 2.00 | EPA 3647014 → |
CK40HT-24B-**+TDR+ furnace: EL297UH070XV36B*AHRI reference: 215710495 | 15.50 | 8.10 | 10600 | 2.00 | EPA 3647016 → |
CK40HT-24B-**+TDR+ furnace: ML180UH070E36B*AHRI reference: 215710496 | 15.50 | 8.10 | 10600 | 2.00 | EPA 3647017 → |
CK40HT-24B-**+TDR+ furnace: ML180UH070V36B*AHRI reference: 215710497 | 15.50 | 8.10 | 10600 | 2.00 | EPA 3647018 → |
CK40HT-24B-**+TDR+ furnace: ML180UH070XE36B*AHRI reference: 215710499 | 15.50 | 8.10 | 10600 | 2.00 | EPA 3647019 → |
CK40HT-24B-**+TDR+ furnace: ML180UH070V48B*AHRI reference: 215710498 | 15.50 | 8.10 | 10700 | 2.02 | EPA 3647020 → |
CK40HT-24B-**+TDR+ furnace: ML180UH090E48B*AHRI reference: 215710500 | 15.50 | 8.10 | 10700 | 2.02 | EPA 3647022 → |
CK40HT-24B-**+TDR+ furnace: ML180UH090XE48B*AHRI reference: 215710502 | 15.50 | 8.10 | 10700 | 2.02 | EPA 3647023 → |
CK40HT-30A-**+TDR+ furnace: EL280UH045E36A*AHRI reference: 215710520 | 15.50 | 7.80 | 10900 | 2.04 | EPA 3647035 → |
CK40HT-30A-**+TDR+ furnace: ML180UH070V36A*AHRI reference: 215710528 | 15.50 | 8.00 | 11000 | 2.04 | EPA 3647043 → |
CK40HT-30B-**+TDR+ furnace: EL196UH030XE36B*AHRI reference: 215710536 | 15.50 | 7.80 | 10800 | 2.04 | EPA 3647049 → |
CK40HT-30B-**+TDR+ furnace: EL280UH090E36B*AHRI reference: 215710539 | 15.50 | 7.80 | 10700 | 2.06 | EPA 3647051 → |
CK40HT-30B-**+TDR+ furnace: EL280UH090E48B*AHRI reference: 215710540 | 15.50 | 8.00 | 11000 | 2.08 | EPA 3647052 → |
CK40HT-30B-**+TDR+ furnace: EL280UH090XE48B*AHRI reference: 215710541 | 15.50 | 8.00 | 11000 | 2.08 | EPA 3647054 → |
CK40HT-30B-**+TDR+ furnace: ML180UH070E36B*AHRI reference: 215710546 | 15.50 | 8.00 | 10900 | 2.08 | EPA 3647057 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.