Lennox / AIR-SOURCE HEAT PUMP

EL16KP1-018-230A**

ELITE EL16KP1 Series · source records, page 2

67 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8BTU/Wh
Cooling capacity18,000BTU/h

Each efficiency range summarizes published EPA records for EL16KP1-018-230A**. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 67 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.567 / 67
EER2 · BTU/Wh13–14.267 / 67
HSPF2 · BTU/Wh7.867 / 67
Cooling capacity · BTU/h18,00067 / 67
Heating capacity at 47°F / 8.3°C · BTU/h17,500–18,00067 / 67
Heating capacity at 17°F / −8.3°C · BTU/h10,500–11,20067 / 67
Heating capacity at 5°F / −15°C · BTU/h7,900–8,50067 / 67
COP at 5°F / −15°C1.86–2.0867 / 67
Equipment / loop typeHP - Split System67 / 67
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)67 / 67
Compressor stagingSingle stage67 / 67
Connected capabilityNo67 / 67

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CK40HT-24A-**+TDR+ furnace: EL280UH070XE36A*AHRI reference: 21568578616.007.8080001.96EPA 3646060
CK40HT-24A-**+TDR+ furnace: ML180UH030V36A*AHRI reference: 21568578716.007.8079001.92EPA 3646061
CK40HT-24A-**+TDR+ furnace: ML180UH045E36A*AHRI reference: 21568578816.007.8079001.94EPA 3646062
CK40HT-24A-**+TDR+ furnace: ML180UH045V36A*AHRI reference: 21568578916.007.8079001.94EPA 3646063
CK40HT-24A-**+TDR+ furnace: ML180UH045XE36A*AHRI reference: 21568579016.007.8079001.94EPA 3646064
CK40HT-24A-**+TDR+ furnace: ML180UH070E36A*AHRI reference: 21568579116.007.8080001.96EPA 3646065
CK40HT-24A-**+TDR+ furnace: ML180UH070V36A*AHRI reference: 21568579216.007.8080001.96EPA 3646066
CK40HT-24A-**+TDR+ furnace: ML180UH070XE36A*AHRI reference: 21568579316.007.8080001.96EPA 3646067
CK40HT-24A-**+TDR+ furnace: SL280UH060NV36A*AHRI reference: 21568579416.007.8080001.96EPA 3646068
CK40HT-24A-**+TDR+ furnace: SL280UH070V36A*AHRI reference: 21568579516.007.8080001.92EPA 3646069
CK40HT-24A-**+TDR+ furnace: SL280UH070XV36A*AHRI reference: 21568579616.007.8080001.92EPA 3646070
CK40HT-24B-**+TDR+ furnace: EL195UH060NE36B*AHRI reference: 21568579816.007.8083001.96EPA 3646071
CK40HT-24B-**+TDR+ furnace: EL280UH090E36B*AHRI reference: 21568580216.007.8083001.96EPA 3646072
CK40HT-24B-**+TDR+ furnace: EL297UH045XE36B*AHRI reference: 21568580316.007.8083001.96EPA 3646073
CK40HT-24B-**+TDR+ furnace: EL297UH070XE36B*AHRI reference: 21568580516.007.8082001.94EPA 3646074
CK40HT-24B-**+TDR+ furnace: EL297UH070XV36B*AHRI reference: 21568580616.007.8083001.96EPA 3646075
CK40HT-24B-**+TDR+ furnace: ML180UH070E36B*AHRI reference: 21568580716.007.8082001.94EPA 3646076
CK40HT-24B-**+TDR+ furnace: ML180UH070V36B*AHRI reference: 21568580816.007.8082001.96EPA 3646077
CK40HT-24B-**+TDR+ furnace: ML180UH070V48B*AHRI reference: 21568580916.007.8082001.96EPA 3646078
CK40HT-24B-**+TDR+ furnace: ML180UH070XE36B*AHRI reference: 21568581016.007.8082001.94EPA 3646079

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →