LBHB12DUWO
LBH series
7 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for LBHB12DUWO. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 7 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 19–23.1 | 7 / 7 |
| EER2 · BTU/Wh | 11.7–14 | 7 / 7 |
| HSPF2 · BTU/Wh | 10–10.8 | 7 / 7 |
| Cooling capacity · BTU/h | 11,500–12,000 | 7 / 7 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 12,000 | 7 / 7 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 8,900–10,000 | 7 / 7 |
| Heating capacity at 5°F / −15°C · BTU/h | 8,000–8,400 | 7 / 7 |
| COP at 5°F / −15°C | 2.26–2.41 | 7 / 7 |
| Equipment / loop type | HP - Mini or Multi Split | 7 / 7 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 7 / 7 |
| Compressor staging | Continuously variable | 7 / 7 |
| Connected capability | No | 7 / 7 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
LBHB12DUWICold climate designationAHRI reference: 208130804 | 23.10 | 10.80 | 8400 | 2.41 | EPA 2470386 → |
LBHB12DUWICold climate designationAHRI reference: 208130804 | 23.10 | 10.80 | 8400 | 2.41 | EPA 3996673 → |
LMHB12DSIAHRI reference: 208130808 | 22.70 | 10.00 | 8000 | 2.27 | EPA 2470391 → |
LMHB12DSIAHRI reference: 208130808 | 22.70 | 10.00 | 8000 | 2.27 | EPA 2470392 → |
LMHB12DZGICold climate designationAHRI reference: 208130820 | 22.70 | 10.20 | 8400 | 2.26 | EPA 2470453 → |
LMHB12DZGICold climate designationAHRI reference: 208130820 | 22.70 | 10.20 | 8400 | 2.26 | EPA 3996668 → |
LMHB12DFICold climate designationAHRI reference: 208130814 | 19.00 | 10.30 | 8400 | 2.26 | EPA 2470393 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →