Kinghome / AIR-SOURCE HEAT PUMP

KW12XQ29S1DO

360°air discharge cassette unit · Airy · Console · Ducted · Floor ceiling · One-way air discharge cassette unit

6 published source records · source checked Sep 21, 2026

SEER2 range20–29.5BTU/Wh
HSPF2 range8.5–10BTU/Wh
Cooling capacity12,000BTU/h

Each efficiency range summarizes published EPA records for KW12XQ29S1DO. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 6 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh20–29.56 / 6
EER2 · BTU/Wh12.3–15.26 / 6
HSPF2 · BTU/Wh8.5–106 / 6
Cooling capacity · BTU/h12,0006 / 6
Heating capacity at 47°F / 8.3°C · BTU/h12,000–12,2006 / 6
Heating capacity at 17°F / −8.3°C · BTU/h10,300–13,0006 / 6
Heating capacity at 5°F / −15°C · BTU/h10,000–12,2006 / 6
COP at 5°F / −15°C1.8–26 / 6
Equipment / loop typeHP - Mini or Multi Split6 / 6
Refrigerant / source-reported GWPR-32 (GWP:675 | Lower GWP)6 / 6
Compressor stagingContinuously variable6 / 6
Connected capabilityNo6 / 6

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
KW12XQ29S1DICold climate designationAHRI reference: 21790355829.5010.00122002.00EPA 4514303
KM12XEDICold climate designationAHRI reference: 21845153423.109.00100001.80EPA 4617814
KM12XTDICold climate designationAHRI reference: 21845153323.008.50100001.90EPA 4617815
KM12XK8DICold climate designationAHRI reference: 21845153123.008.50100001.90EPA 4617817
KM12XFDICold climate designationAHRI reference: 21845153021.509.00105001.90EPA 4617818
KM12XK1DICold climate designationAHRI reference: 21845153220.008.50100001.90EPA 4617816

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →