Kenmore / AIR-SOURCE HEAT PUMP

XH648E2S11*

LX SERIES · source records, page 3

223 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity45,500–48,000BTU/h

Each efficiency range summarizes published EPA records for XH648E2S11*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 223 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16223 / 223
EER2 · BTU/Wh11.7–12223 / 223
HSPF2 · BTU/Wh7.8–8.1223 / 223
Cooling capacity · BTU/h45,500–48,000223 / 223
Heating capacity at 47°F / 8.3°C · BTU/h46,000–50,000223 / 223
Heating capacity at 17°F / −8.3°C · BTU/h31,800–34,000223 / 223
Heating capacity at 5°F / −15°C · BTU/h26,400–27,800223 / 223
COP at 5°F / −15°C2.1–2.38223 / 223
Equipment / loop typeHP - Split System223 / 223
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)223 / 223
Compressor stagingTwo-stage223 / 223
Connected capabilityNo223 / 223

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTM60C5CHS2+ furnace: Z8ES120C20SMPS1*AHRI reference: 21860161616.008.10274002.32EPA 4651109 →
CTM60C5CHS2+ furnace: Z9ET080C16SMPS1AHRI reference: 21860161416.007.80268002.30EPA 4651110 →
CTM60C5CHS2+ furnace: Z9ES080C16SMPS1*AHRI reference: 21860161216.007.80268002.30EPA 4651111 →
CTM60C5CHS2+ furnace: Z8ES100C16LMPS1*AHRI reference: 21860161116.008.10274002.32EPA 4651112 →
CTM60C5CHS2+ furnace: Z8ES100C16SMPS1*AHRI reference: 21860160916.008.10274002.32EPA 4651113 →
CTM60C5CHS2+ furnace: Z8ET080C16LMPS1*AHRI reference: 21860160716.008.10266002.34EPA 4651114 →
CTM60C5CHS2+ furnace: Z8ET100C16LMPS1*AHRI reference: 21860160616.008.10272002.32EPA 4651115 →
CTM60C5CHS2+ furnace: Z8VT120C20SMPC1AHRI reference: 21860160416.008.10270002.36EPA 4651116 →
CTM60C5CHS2+ furnace: Z8VT100C20SMPC1AHRI reference: 21860160216.008.10270002.34EPA 4651117 →
CTM60C5CHS2+ furnace: Z8VT100C16SMPC1AHRI reference: 21860160016.008.10274002.32EPA 4651118 →
CTM60C5CHS2+ furnace: Z8VT080C16SMPC1AHRI reference: 21860159916.008.10274002.34EPA 4651119 →
CTM60C5CGS2+ furnace: Z8VT100C20SMPC1AHRI reference: 21860159716.008.10274002.26EPA 4651120 →
CTM60C5CGS2+ furnace: Z8VT100C16SMPC1AHRI reference: 21860159516.008.10274002.26EPA 4651121 →
CTM60C5CGS2+ furnace: Z8VT080C16SMPC1AHRI reference: 21860159316.008.10276002.26EPA 4651122 →
CTM60C5CGS2+ furnace: Z8VT120C20SMPC1AHRI reference: 21860159216.008.10272002.28EPA 4651123 →
CTM60C5CGS2+ furnace: Z8ES120C16LMPS1*AHRI reference: 21860159016.008.10274002.26EPA 4651124 →
CTM60C5CGS2+JMC16C2SN1AHRI reference: 21860156016.008.10272002.28EPA 4651125 →
CTM60C5CGS2+ furnace: Z8ET100C20LMPS1*AHRI reference: 21860155816.008.10276002.26EPA 4651126 →
CTM60C5CGS2+ furnace: Z8ET120C20LMPS1*AHRI reference: 21860155616.008.10276002.26EPA 4651127 →
CTM60C5CGS2+ furnace: Z8ES120C20LMPS1*AHRI reference: 21860155516.008.10272002.26EPA 4651128 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →