Kenmore / AIR-SOURCE HEAT PUMP

XH648E2S11*

LX SERIES

223 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity45,500–48,000BTU/h

Each efficiency range summarizes published EPA records for XH648E2S11*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 223 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16223 / 223
EER2 · BTU/Wh11.7–12223 / 223
HSPF2 · BTU/Wh7.8–8.1223 / 223
Cooling capacity · BTU/h45,500–48,000223 / 223
Heating capacity at 47°F / 8.3°C · BTU/h46,000–50,000223 / 223
Heating capacity at 17°F / −8.3°C · BTU/h31,800–34,000223 / 223
Heating capacity at 5°F / −15°C · BTU/h26,400–27,800223 / 223
COP at 5°F / −15°C2.1–2.38223 / 223
Equipment / loop typeHP - Split System223 / 223
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)223 / 223
Compressor stagingTwo-stage223 / 223
Connected capabilityNo223 / 223

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTU60C5XGS1+TXV+ furnace: Z8VT080C16SMPC1AHRI reference: 21744536416.008.10276002.26EPA 4042970
CTF60C5CGS1+ furnace: Z8VT120C20SMPC1AHRI reference: 21744536516.008.10272002.26EPA 4042971
CTU60C5XGS1+TXV+ furnace: Z8VT120C20SMPC1AHRI reference: 21744536616.008.10272002.26EPA 4042972
CTM60C5CHS1+ furnace: Z8VT080C16SMPC1AHRI reference: 21744536716.008.10274002.34EPA 4042973
CTF60C5CHS1+ furnace: Z8VT100C16SMPC1AHRI reference: 21744536816.008.10274002.32EPA 4042974
CTM60C5CHS1+ furnace: Z8VT100C16SMPC1AHRI reference: 21744536916.008.10274002.32EPA 4042975
CTM60C5CHS1+ furnace: Z8VT100C20SMPC1AHRI reference: 21744537016.008.10270002.34EPA 4042976
CTM60C5CHS1+ furnace: Z8VT120C20SMPC1AHRI reference: 21744537116.008.10270002.36EPA 4042977
CTF60C5CHS1+ furnace: Z8VT100C20SMPC1AHRI reference: 21744537216.008.10270002.34EPA 4042979
CTF60C5CHS1+ furnace: Z8VT120C20SMPC1AHRI reference: 21744537316.008.10270002.36EPA 4042980
CTF60C5CHS1+ furnace: Z8VT080C16SMPC1AHRI reference: 21744537416.008.10274002.34EPA 4042981
CTF60C5CGS1+ furnace: Z8VT080C16SMPC1AHRI reference: 21744536316.008.10276002.26EPA 4042991
CTM60C5CGS1+ furnace: Z8VT100C20SMPC1AHRI reference: 21744535516.008.10274002.26EPA 4042998
CTF60C5CGS1+ furnace: Z8VT100C16SMPC1AHRI reference: 21744535616.008.10274002.26EPA 4042999
CTU60C5XGS1+TXV+ furnace: Z8VT100C16SMPC1AHRI reference: 21744535716.008.10274002.26EPA 4043000
CTM60C5CGS1+ furnace: Z8VT100C16SMPC1AHRI reference: 21744535816.008.10274002.26EPA 4043001
CTF60C5CGS1+ furnace: Z8VT100C20SMPC1AHRI reference: 21744535916.008.10274002.26EPA 4043002
CTU60C5XGS1+TXV+ furnace: Z8VT100C20SMPC1AHRI reference: 21744536016.008.10274002.26EPA 4043003
CTM60C5CGS1+ furnace: Z8VT120C20SMPC1AHRI reference: 21744536116.008.10272002.28EPA 4043004
CTM60C5CGS1+ furnace: Z8VT080C16SMPC1AHRI reference: 21744536216.008.10276002.26EPA 4043005

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →