Kenmore / AIR-SOURCE HEAT PUMP

XH636E2S11*

LX SERIES

223 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range8–8.5BTU/Wh
Cooling capacity33,000–36,000BTU/h

Each efficiency range summarizes published EPA records for XH636E2S11*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 223 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17223 / 223
EER2 · BTU/Wh11–12223 / 223
HSPF2 · BTU/Wh8–8.5223 / 223
Cooling capacity · BTU/h33,000–36,000223 / 223
Heating capacity at 47°F / 8.3°C · BTU/h34,000–36,200223 / 223
Heating capacity at 17°F / −8.3°C · BTU/h22,000–23,800223 / 223
Heating capacity at 5°F / −15°C · BTU/h18,000–19,800223 / 223
COP at 5°F / −15°C2–2.5223 / 223
Equipment / loop typeHP - Split System223 / 223
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)223 / 223
Compressor stagingTwo-stage223 / 223
Connected capabilityNo223 / 223

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTU48C5XFS1+TXV+ furnace: Z8ES080C20SMPS1*AHRI reference: 21773895717.008.50193002.42EPA 4510621
CTU48C5XFS1+TXV+ furnace: Z9ES080C16SMPS1*AHRI reference: 21773895817.008.10189002.40EPA 4510622
CTF48C5CFS1+ furnace: Z8ET100C20LMPS1*AHRI reference: 21773895917.008.10192002.44EPA 4510623
CTU48C5XFS1+TXV+ furnace: Z8ET100C20LMPS1*AHRI reference: 21773896017.008.10192002.44EPA 4510624
CTF48C5CFS1+ furnace: Z8ES100C16LMPS1*AHRI reference: 21773896117.008.50195002.42EPA 4510625
CTF48C5CFS1+ furnace: Z8ES120C16SMPS1*AHRI reference: 21773896317.008.50191002.44EPA 4510626
CTU48C5XFS1+TXV+ furnace: Z8ET100C16LMPS1*AHRI reference: 21773896517.008.50193002.44EPA 4510627
CTF48D5CFS1+JMC20D2SN1AHRI reference: 21773896617.008.50191002.50EPA 4510628
CTF48C5CFS1+ furnace: Z8ES080C20SMPS1*AHRI reference: 21773896717.008.50193002.42EPA 4510629
CTF48C5CFS1+ furnace: Z9ES080C16SMPS1*AHRI reference: 21773896817.008.10189002.40EPA 4510630
CTU48C5XFS1+TXV+ furnace: Z9ES080C20SMPS1*AHRI reference: 21773896917.008.10194002.40EPA 4510631
CTF48C5CFS1+ furnace: Z8ES100C16SMPS1*AHRI reference: 21773897017.008.50195002.42EPA 4510632
CTU48C5XFS1+TXV+ furnace: Z8ES120C16LMPS1*AHRI reference: 21773897117.008.50191002.44EPA 4510633
CTF48C5CFS1+JMC16C2SN1AHRI reference: 21773897317.008.50193002.46EPA 4510634
CTU48C5XFS1+JMC16C2SN1+TXVAHRI reference: 21773897417.008.50193002.46EPA 4510635
CTF48C5CFS1+ furnace: Z8ET080C16LMPS1*AHRI reference: 21773897517.008.50193002.44EPA 4510636
CTU48C5XFS1+TXV+ furnace: Z8ET080C16LMPS1*AHRI reference: 21773897617.008.50193002.44EPA 4510637
CTF48C5CFS1+ furnace: Z8ET120C20LMPS1*AHRI reference: 21773897717.008.10194002.44EPA 4510638
CTF48C5CFS1+JMC17C2SN1AHRI reference: 21773897917.008.50191002.46EPA 4510639
CTU48C5XFS1+JMC17C2SN1+TXVAHRI reference: 21773898017.008.50191002.46EPA 4510640

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →