Kenmore / AIR-SOURCE HEAT PUMP

XH630E2S11

LX SERIES · source records, page 2

95 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range8–8.1BTU/Wh
Cooling capacity28,800–31,000BTU/h

Each efficiency range summarizes published EPA records for XH630E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 95 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–1795 / 95
EER2 · BTU/Wh11–1395 / 95
HSPF2 · BTU/Wh8–8.195 / 95
Cooling capacity · BTU/h28,800–31,00095 / 95
Heating capacity at 47°F / 8.3°C · BTU/h28,800–29,80095 / 95
Heating capacity at 17°F / −8.3°C · BTU/h18,800–20,20095 / 95
Heating capacity at 5°F / −15°C · BTU/h15,000–16,40095 / 95
COP at 5°F / −15°C2–2.495 / 95
Equipment / loop typeHP - Split System95 / 95
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)95 / 95
Compressor stagingTwo-stage95 / 95
Connected capabilityNo95 / 95

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
JHE30B5AD2SS1AHRI reference: 21841666716.008.00154002.36EPA 4608505 →
CTU36B5XDS1+TXV+ furnace: Z9ET060B12SMPS1*AHRI reference: 21841858616.008.10158002.28EPA 4608509 →
CTF36B5ADS1+ furnace: Z9ET060B12SMPS1*AHRI reference: 21841858516.008.10158002.28EPA 4608510 →
CTM36B5ADS1+ furnace: Z9ET060B12SMPS1*AHRI reference: 21841858416.008.00158002.26EPA 4608511 →
CTM36B5ADS1+ furnace: Z9ES060B12SMPS1*AHRI reference: 21841858316.008.00158002.26EPA 4608512 →
CTM36B5ADS1+ furnace: Z9ET080B12SMPS1*AHRI reference: 21841858216.008.10156002.30EPA 4608513 →
CTF36C5ADS1+ furnace: Z8ES080C20LMPS1*AHRI reference: 21841858116.008.10152002.36EPA 4608514 →
CTF36C5ADS1+ furnace: Z8ES080C20SMPS1*AHRI reference: 21841858016.008.10152002.36EPA 4608515 →
CTF36C5ADS1+ furnace: Z9ES080C16SMPS1*AHRI reference: 21841857916.008.10154002.34EPA 4608516 →
CTM36B5ADS1+ furnace: Z8ES080B12LMPS1*AHRI reference: 21841862216.008.10154002.32EPA 4609434 →
CTM36B5ADS1+ furnace: Z8ES080B12SMPS1*AHRI reference: 21841862116.008.10154002.32EPA 4609435 →
CTM36B5ADS1+ furnace: Z8ES100B12LMPS1*AHRI reference: 21841862016.008.10152002.34EPA 4609436 →
CTM36B5ADS1+ furnace: Z8ES100B12SMPS1*AHRI reference: 21841861916.008.10152002.34EPA 4609437 →
CTU36B5XDS1+TXV+ furnace: Z8VT080B12SMPC1AHRI reference: 21841861816.008.10150002.38EPA 4609438 →
CTF36B5ADS1+ furnace: Z8VT080B12SMPC1AHRI reference: 21841861716.008.10150002.38EPA 4609439 →
CTM36B5ADS1+ furnace: Z8VT080B12SMPC1AHRI reference: 21841861616.008.10152002.36EPA 4609440 →
CTU36B5XDS1+TXV+ furnace: Z9ES060B12SMPS1*AHRI reference: 21841861516.008.10158002.28EPA 4609441 →
CTF36B5ADS1+ furnace: Z9ES060B12SMPS1*AHRI reference: 21841861416.008.10158002.28EPA 4609442 →
CTU36B5XDS1+TXV+ furnace: Z9ET080B12SMPS1*AHRI reference: 21841861316.008.10156002.30EPA 4609443 →
CTF36B5ADS1+ furnace: Z9ET080B12SMPS1*AHRI reference: 21841861216.008.10156002.30EPA 4609444 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →