Kenmore / AIR-SOURCE HEAT PUMP

XH624E2S11*

LX SERIES · source records, page 3

64 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity22,800–24,200BTU/h

Each efficiency range summarizes published EPA records for XH624E2S11*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 64 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–1664 / 64
EER2 · BTU/Wh11.7–1264 / 64
HSPF2 · BTU/Wh7.8–8.164 / 64
Cooling capacity · BTU/h22,800–24,20064 / 64
Heating capacity at 47°F / 8.3°C · BTU/h22,600–23,80064 / 64
Heating capacity at 17°F / −8.3°C · BTU/h14,500–15,50064 / 64
Heating capacity at 5°F / −15°C · BTU/h11,900–12,80064 / 64
COP at 5°F / −15°C2.1–2.364 / 64
Equipment / loop typeHP - Split System64 / 64
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)64 / 64
Compressor stagingTwo-stage64 / 64
Connected capabilityNo64 / 64

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTF30B5ACS2+JMC12B2SN1AHRI reference: 21860113316.007.80122002.14EPA 4652387
CTF30C5ACS2+JME12C2SN2AHRI reference: 21863752516.007.80123002.14EPA 4663988
CTU36B5XDS2+JME12B2SN2+TXVAHRI reference: 21863751116.008.00120002.26EPA 4663999
CTF36B5ADS2+JME12B2SN2AHRI reference: 21863750916.008.00120002.26EPA 4664001
CTF30C5ACS2+JME16C2SN2AHRI reference: 21863750716.007.80123002.16EPA 4664003
CTF30A5ADS1+ furnace: Z8VT060A12SMPC1AHRI reference: 21744535115.208.10125002.26EPA 4042995
CTM36B5ADS1+ furnace: Z8VT080B12SMPC1AHRI reference: 21744535415.208.10124002.28EPA 4042997
CTM36B5ADS2+ furnace: Z8VT080B12SMPC1AHRI reference: 21860122515.208.10124002.28EPA 4651190
CTM36B5ADS2+ furnace: Z9ET060B12SMPS1*AHRI reference: 21860122315.208.10126002.22EPA 4651191
CTM36B5ADS2+JMC12B2SN1AHRI reference: 21860121615.208.10123002.28EPA 4651195
CTU36B5XDS2+TXV+ furnace: Z9ET060B12SMPS1*AHRI reference: 21860116115.208.10126002.22EPA 4651206
CTF36B5ADS2+ furnace: Z9ET060B12SMPS1*AHRI reference: 21860115915.208.10126002.22EPA 4651207
CTM36B5ADS2+ furnace: Z8ES080B12LMPS1*AHRI reference: 21860123415.208.10124002.26EPA 4652370
CTM36B5ADS2+ furnace: Z8ES080B12SMPS1*AHRI reference: 21860123215.208.10124002.26EPA 4652371
CTM36B5ADS2+ furnace: Z9ES060B12SMPS1*AHRI reference: 21860123015.208.10128002.22EPA 4652372
CTM36B5ADS2+ furnace: Z9ES080B12SMPS1*AHRI reference: 21860122915.207.80124002.22EPA 4652373
CTM36B5ADS2+ furnace: Z9ET080B12SMPS1*AHRI reference: 21860122715.207.80121002.20EPA 4652374
CTU36B5XDS2+TXV+ furnace: Z9ES060B12SMPS1*AHRI reference: 21860118215.208.10125002.24EPA 4652378
CTF36B5ADS2+ furnace: Z9ES060B12SMPS1*AHRI reference: 21860118015.208.10125002.24EPA 4652379
CTF30A5ADS2+ furnace: Z8VT060A12SMPC1AHRI reference: 21860110915.208.10125002.26EPA 4652390

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.