Kenmore / AIR-SOURCE HEAT PUMP

XH618E2S11

LX SERIES · source records, page 5

146 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8BTU/Wh
Cooling capacity17,000–18,300BTU/h

Each efficiency range summarizes published EPA records for XH618E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 146 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16146 / 146
EER2 · BTU/Wh12–12.5146 / 146
HSPF2 · BTU/Wh7.8–8146 / 146
Cooling capacity · BTU/h17,000–18,300146 / 146
Heating capacity at 47°F / 8.3°C · BTU/h16,100–16,900146 / 146
Heating capacity at 17°F / −8.3°C · BTU/h10,700–11,200146 / 146
Heating capacity at 5°F / −15°C · BTU/h8,700–9,100146 / 146
COP at 5°F / −15°C2.26–2.34146 / 146
Equipment / loop typeHP - Split System146 / 146
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)146 / 146
Compressor stagingSingle stage146 / 146
Connected capabilityNo146 / 146

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTM24B5ABS1+ furnace: Z8ET080B12LMPS1*AHRI reference: 21841848115.207.8088002.28EPA 4609533 →
CTF24B5ABS1+ furnace: Z8ES080B12LMPS1*AHRI reference: 21841848015.207.8088002.28EPA 4609534 →
CTF24B5ABS1+ furnace: Z8ES080B12SMPS1*AHRI reference: 21841847915.207.8088002.28EPA 4609535 →
CTM24B5ABS1+ furnace: Z8ES100B12LMPS1*AHRI reference: 21841847815.207.8088002.28EPA 4609536 →
CTM24B5ABS1+ furnace: Z8ES100B12SMPS1*AHRI reference: 21841847715.207.8088002.28EPA 4609537 →
CTM24B5ABS1+ furnace: Z8ES080B12LMPS1*AHRI reference: 21841847215.207.8088002.28EPA 4609539 →
CTM24B5ABS1+ furnace: Z8ES080B12SMPS1*AHRI reference: 21841847115.207.8088002.28EPA 4609540 →
CTF24B5ABS1+ furnace: Z8ET080B12LMPS1*AHRI reference: 21841846915.207.8088002.30EPA 4609541 →
CTF24B5ABS1+ furnace: Z9ES080B12SMPS1*AHRI reference: 21841846815.207.8087002.30EPA 4609542 →
CTF24B5ABS1+ furnace: Z9ET080B12SMPS1*AHRI reference: 21841846715.207.8090002.28EPA 4609543 →
CTF24B5ABS2+ furnace: Z8ES080B12SMPS1*AHRI reference: 21860171515.207.8088002.28EPA 4651090 →
CTF24B5ABS2+ furnace: Z8ES080B12LMPS1*AHRI reference: 21860171315.207.8088002.28EPA 4651091 →
CTF24B5ABS2+JMC12B2SN1AHRI reference: 21860170915.207.8089002.32EPA 4651092 →
CTU24A5XBS2+TXV+ furnace: Z8ET060A12LMPS1*AHRI reference: 21860170615.207.8088002.28EPA 4651094 →
CTF24A5ABS2+ furnace: Z8ET060A12LMPS1*AHRI reference: 21860170415.207.8088002.28EPA 4651095 →
CTU24A5XBS2+TXV+ furnace: Z8VT060A12SMPC1AHRI reference: 21860170215.207.8089002.32EPA 4651096 →
CTU24A5XBS2+TXV+ furnace: Z8ES060A12SMPS1*AHRI reference: 21860168515.207.8088002.28EPA 4651097 →
CTU24A5XBS2+TXV+ furnace: Z8ES060A12LMPS1*AHRI reference: 21860168315.207.8088002.28EPA 4651098 →
CTF24A5ABS2+ furnace: Z8ES060A12LMPS1*AHRI reference: 21860168115.207.8088002.28EPA 4651099 →
CTF24A5ABS2+ furnace: Z8ES060A12SMPS1*AHRI reference: 21860167915.207.8088002.28EPA 4651100 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →