XH560E2S11*
LX SERIES
22 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for XH560E2S11*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 22 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2 | 22 / 22 |
| EER2 · BTU/Wh | 11–11.7 | 22 / 22 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 22 / 22 |
| Cooling capacity · BTU/h | 54,500–56,500 | 22 / 22 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 55,500–57,000 | 22 / 22 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 37,400–39,000 | 22 / 22 |
| Heating capacity at 5°F / −15°C · BTU/h | 29,800–32,400 | 22 / 22 |
| COP at 5°F / −15°C | 2.1–2.38 | 22 / 22 |
| Equipment / loop type | HP - Split System | 22 / 22 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 22 / 22 |
| Compressor staging | Two-stage | 22 / 22 |
| Connected capability | No | 22 / 22 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTM60C5CHS1+ furnace: Z8VT120C20SMPC1AHRI reference: 217445085 | 15.20 | 7.80 | 32400 | 2.28 | EPA 4570480 → |
CTF60C5CHS1+ furnace: Z8VT120C20SMPC1AHRI reference: 217445084 | 15.20 | 7.80 | 32400 | 2.28 | EPA 4570481 → |
CTU60D5XHS1+JME18D2SN1+TXVAHRI reference: 216942479 | 15.20 | 7.80 | 31600 | 2.30 | EPA 4570697 → |
CTF60D5CHS1+JME18D2SN1AHRI reference: 216942477 | 15.20 | 7.80 | 31600 | 2.30 | EPA 4570698 → |
JHE60D5CH2SS1AHRI reference: 216941682 | 15.20 | 7.80 | 29800 | 2.10 | EPA 4570702 → |
CTM60D5CHS1+JME18D2SN1AHRI reference: 216940995 | 15.20 | 7.80 | 31600 | 2.30 | EPA 4570707 → |
CTM60C5CHS1+JME16C2SN1AHRI reference: 216940993 | 15.20 | 7.80 | 31400 | 2.26 | EPA 4570708 → |
JHC60D5CH2SS1AHRI reference: 216940632 | 15.20 | 7.80 | 31600 | 2.30 | EPA 4570713 → |
CTM60D5CJS1+JME18D2SN1AHRI reference: 216940470 | 15.20 | 8.10 | 31600 | 2.38 | EPA 4570717 → |
JHC60C5CH2SS1AHRI reference: 216940458 | 15.20 | 7.80 | 31600 | 2.26 | EPA 4570718 → |
JHE60D5CH2SS2AHRI reference: 218457338 | 15.20 | 7.80 | 29800 | 2.10 | EPA 4622466 → |
CTM60D5CJS2+JMC20D2SN1AHRI reference: 218600574 | 15.20 | 8.10 | 31400 | 2.34 | EPA 4651381 → |
CTM60D5CHS2+JMC20D2SN1AHRI reference: 218600568 | 15.20 | 7.80 | 31800 | 2.30 | EPA 4651382 → |
CTM60C5CHS2+ furnace: Z8VT120C20SMPC1AHRI reference: 218600564 | 15.20 | 7.80 | 32400 | 2.28 | EPA 4651383 → |
CTM60C5CHS2+ furnace: Z8ES100C20LMPS1*AHRI reference: 218600559 | 15.20 | 7.80 | 31600 | 2.26 | EPA 4651384 → |
CTM60C5CHS2+ furnace: Z8ES100C20SMPS1*AHRI reference: 218600558 | 15.20 | 7.80 | 31600 | 2.26 | EPA 4651385 → |
CTF60D5CHS2+JMC20D2SN1AHRI reference: 218600535 | 15.20 | 7.80 | 31800 | 2.30 | EPA 4651386 → |
CTF60D5CHS2+ furnace: Z8ES130D20LMPS1*AHRI reference: 218600534 | 15.20 | 7.80 | 31600 | 2.26 | EPA 4651387 → |
CTF60D5CHS2+ furnace: Z8ES130D20SMPS1*AHRI reference: 218600533 | 15.20 | 7.80 | 31600 | 2.26 | EPA 4651388 → |
CTF60C5CHS2+ furnace: Z8VT120C20SMPC1AHRI reference: 218600515 | 15.20 | 7.80 | 32400 | 2.28 | EPA 4651389 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →