XH536E2S11*
LX SERIES · source records, page 5
122 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for XH536E2S11*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 122 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 122 / 122 |
| EER2 · BTU/Wh | 11–12 | 122 / 122 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 122 / 122 |
| Cooling capacity · BTU/h | 32,400–35,000 | 122 / 122 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 30,600–32,600 | 122 / 122 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 20,400–22,000 | 122 / 122 |
| Heating capacity at 5°F / −15°C · BTU/h | 17,000–18,400 | 122 / 122 |
| COP at 5°F / −15°C | 2–2.44 | 122 / 122 |
| Equipment / loop type | HP - Split System | 122 / 122 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 122 / 122 |
| Compressor staging | Two-stage | 122 / 122 |
| Connected capability | No | 122 / 122 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTM48C5CFS2+ furnace: Z8VT100C20SMPC1AHRI reference: 218599653 | 15.20 | 8.10 | 17800 | 2.40 | EPA 4651994 → |
CTM48C5CFS2+ furnace: Z8ET120C20LMPS1*AHRI reference: 218599650 | 15.20 | 8.10 | 18100 | 2.38 | EPA 4651997 → |
CTM48C5CFS2+ furnace: Z8ES080C20LMPS1*AHRI reference: 218599649 | 15.20 | 8.10 | 17900 | 2.38 | EPA 4651998 → |
CTM48C5CFS2+ furnace: Z8ES080C20SMPS1*AHRI reference: 218599648 | 15.20 | 8.10 | 17900 | 2.38 | EPA 4651999 → |
CTM48C5CFS2+ furnace: Z8ET100C16LMPS1*AHRI reference: 218599647 | 15.20 | 8.10 | 18000 | 2.38 | EPA 4652000 → |
CTM48C5CFS2+ furnace: Z9ET080C16SMPS1AHRI reference: 218599646 | 15.20 | 8.10 | 18300 | 2.32 | EPA 4652001 → |
CTM48C5CFS2+ furnace: Z9ES080C16SMPS1*AHRI reference: 218599645 | 15.20 | 8.10 | 18300 | 2.32 | EPA 4652002 → |
CTM48C5CFS2+ furnace: Z8ES100C16LMPS1*AHRI reference: 218599644 | 15.20 | 8.10 | 17800 | 2.40 | EPA 4652003 → |
CTM48C5CFS2+ furnace: Z8ES100C16SMPS1*AHRI reference: 218599643 | 15.20 | 8.10 | 17800 | 2.40 | EPA 4652004 → |
CTM48C5CFS2+ furnace: Z8ET080C16LMPS1*AHRI reference: 218599642 | 15.20 | 8.10 | 18000 | 2.38 | EPA 4652005 → |
CTM48C5CFS2+ furnace: Z9ET100C16SMPS1AHRI reference: 218599641 | 15.20 | 8.10 | 17800 | 2.36 | EPA 4652006 → |
CTM48C5CFS2+ furnace: Z8ES120C16LMPS1*AHRI reference: 218599640 | 15.20 | 8.10 | 17700 | 2.40 | EPA 4652007 → |
CTM48C5CFS2+ furnace: Z8ES120C16SMPS1*AHRI reference: 218599639 | 15.20 | 8.10 | 17700 | 2.40 | EPA 4652008 → |
CTM48C5CFS2+JMC16C2SN1AHRI reference: 218599638 | 15.20 | 8.10 | 17500 | 2.42 | EPA 4652009 → |
CTM48C5CFS2+ furnace: Z8ET100C20LMPS1*AHRI reference: 218599637 | 15.20 | 8.10 | 17900 | 2.40 | EPA 4652010 → |
CTM48C5CFS2+JMC17C2SN1AHRI reference: 218599636 | 15.20 | 8.10 | 17500 | 2.44 | EPA 4652011 → |
CTM36C5CDS2+JMC16C2SN1AHRI reference: 218599635 | 15.20 | 8.10 | 17600 | 2.44 | EPA 4652012 → |
CTM36C5CDS2+ furnace: Z8ES080C20LMPS1*AHRI reference: 218599632 | 15.20 | 8.10 | 17900 | 2.40 | EPA 4652013 → |
CTM36C5CDS2+JMC17C2SN1AHRI reference: 218599631 | 15.20 | 8.10 | 17700 | 2.44 | EPA 4652014 → |
CTM36C5CDS2+ furnace: Z8ES080C20SMPS1*AHRI reference: 218599630 | 15.20 | 8.10 | 17900 | 2.40 | EPA 4652015 → |