Kenmore / AIR-SOURCE HEAT PUMP

XH536E2S11*

LX SERIES · source records, page 5

122 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity32,400–35,000BTU/h

Each efficiency range summarizes published EPA records for XH536E2S11*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 122 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16122 / 122
EER2 · BTU/Wh11–12122 / 122
HSPF2 · BTU/Wh7.8–8.1122 / 122
Cooling capacity · BTU/h32,400–35,000122 / 122
Heating capacity at 47°F / 8.3°C · BTU/h30,600–32,600122 / 122
Heating capacity at 17°F / −8.3°C · BTU/h20,400–22,000122 / 122
Heating capacity at 5°F / −15°C · BTU/h17,000–18,400122 / 122
COP at 5°F / −15°C2–2.44122 / 122
Equipment / loop typeHP - Split System122 / 122
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)122 / 122
Compressor stagingTwo-stage122 / 122
Connected capabilityNo122 / 122

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTM48C5CFS2+ furnace: Z8VT100C20SMPC1AHRI reference: 21859965315.208.10178002.40EPA 4651994
CTM48C5CFS2+ furnace: Z8ET120C20LMPS1*AHRI reference: 21859965015.208.10181002.38EPA 4651997
CTM48C5CFS2+ furnace: Z8ES080C20LMPS1*AHRI reference: 21859964915.208.10179002.38EPA 4651998
CTM48C5CFS2+ furnace: Z8ES080C20SMPS1*AHRI reference: 21859964815.208.10179002.38EPA 4651999
CTM48C5CFS2+ furnace: Z8ET100C16LMPS1*AHRI reference: 21859964715.208.10180002.38EPA 4652000
CTM48C5CFS2+ furnace: Z9ET080C16SMPS1AHRI reference: 21859964615.208.10183002.32EPA 4652001
CTM48C5CFS2+ furnace: Z9ES080C16SMPS1*AHRI reference: 21859964515.208.10183002.32EPA 4652002
CTM48C5CFS2+ furnace: Z8ES100C16LMPS1*AHRI reference: 21859964415.208.10178002.40EPA 4652003
CTM48C5CFS2+ furnace: Z8ES100C16SMPS1*AHRI reference: 21859964315.208.10178002.40EPA 4652004
CTM48C5CFS2+ furnace: Z8ET080C16LMPS1*AHRI reference: 21859964215.208.10180002.38EPA 4652005
CTM48C5CFS2+ furnace: Z9ET100C16SMPS1AHRI reference: 21859964115.208.10178002.36EPA 4652006
CTM48C5CFS2+ furnace: Z8ES120C16LMPS1*AHRI reference: 21859964015.208.10177002.40EPA 4652007
CTM48C5CFS2+ furnace: Z8ES120C16SMPS1*AHRI reference: 21859963915.208.10177002.40EPA 4652008
CTM48C5CFS2+JMC16C2SN1AHRI reference: 21859963815.208.10175002.42EPA 4652009
CTM48C5CFS2+ furnace: Z8ET100C20LMPS1*AHRI reference: 21859963715.208.10179002.40EPA 4652010
CTM48C5CFS2+JMC17C2SN1AHRI reference: 21859963615.208.10175002.44EPA 4652011
CTM36C5CDS2+JMC16C2SN1AHRI reference: 21859963515.208.10176002.44EPA 4652012
CTM36C5CDS2+ furnace: Z8ES080C20LMPS1*AHRI reference: 21859963215.208.10179002.40EPA 4652013
CTM36C5CDS2+JMC17C2SN1AHRI reference: 21859963115.208.10177002.44EPA 4652014
CTM36C5CDS2+ furnace: Z8ES080C20SMPS1*AHRI reference: 21859963015.208.10179002.40EPA 4652015

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →