XH536E2S11*
LX SERIES · source records, page 2
122 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for XH536E2S11*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 122 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 122 / 122 |
| EER2 · BTU/Wh | 11–12 | 122 / 122 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 122 / 122 |
| Cooling capacity · BTU/h | 32,400–35,000 | 122 / 122 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 30,600–32,600 | 122 / 122 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 20,400–22,000 | 122 / 122 |
| Heating capacity at 5°F / −15°C · BTU/h | 17,000–18,400 | 122 / 122 |
| COP at 5°F / −15°C | 2–2.44 | 122 / 122 |
| Equipment / loop type | HP - Split System | 122 / 122 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 122 / 122 |
| Compressor staging | Two-stage | 122 / 122 |
| Connected capability | No | 122 / 122 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTF48C5CFS1+ furnace: Z8VT100C20SMPC1AHRI reference: 217445056 | 15.20 | 8.10 | 17800 | 2.40 | EPA 4045182 → |
CTF48C5CFS1+ furnace: Z8VT120C20SMPC1AHRI reference: 217445058 | 15.20 | 8.10 | 17700 | 2.42 | EPA 4045183 → |
JHE42C5CF2SS1AHRI reference: 216941337 | 15.20 | 8.10 | 17300 | 2.00 | EPA 4498123 → |
JHE36B5CD2SS1AHRI reference: 216941661 | 15.20 | 8.10 | 17600 | 2.00 | EPA 4498124 → |
JHE36C5CD2SS1AHRI reference: 216942281 | 15.20 | 7.80 | 17000 | 2.30 | EPA 4570699 → |
JHE36C5CD2SS2AHRI reference: 218457322 | 15.20 | 7.80 | 17000 | 2.30 | EPA 4639411 → |
JHE42C5CF2SS2AHRI reference: 218457321 | 15.20 | 8.10 | 17300 | 2.00 | EPA 4639412 → |
JHE36B5CD2SS2AHRI reference: 218457320 | 15.20 | 8.10 | 17600 | 2.00 | EPA 4639413 → |
CTU48C5XFS2+TXV+ furnace: Z8VT120C20SMPC1AHRI reference: 218599717 | 15.20 | 8.10 | 17700 | 2.42 | EPA 4651938 → |
CTM48D5CFS2+JMC20D2SN1AHRI reference: 218599716 | 15.20 | 8.10 | 17700 | 2.44 | EPA 4651939 → |
CTF48C5CFS2+ furnace: Z8VT120C20SMPC1AHRI reference: 218599715 | 15.20 | 8.10 | 17700 | 2.42 | EPA 4651940 → |
CTU48C5XFS2+TXV+ furnace: Z8VT100C20SMPC1AHRI reference: 218599714 | 15.20 | 8.10 | 17800 | 2.40 | EPA 4651941 → |
CTF48C5CFS2+ furnace: Z8VT100C20SMPC1AHRI reference: 218599713 | 15.20 | 8.10 | 17800 | 2.40 | EPA 4651942 → |
CTU48C5XFS2+TXV+ furnace: Z8ES100C16SMPS1*AHRI reference: 218599708 | 15.20 | 8.10 | 17500 | 2.00 | EPA 4651947 → |
CTU48C5XFS2+TXV+ furnace: Z8ES100C16LMPS1*AHRI reference: 218599707 | 15.20 | 8.10 | 17500 | 2.00 | EPA 4651948 → |
CTF48C5CFS2+ furnace: Z8ES100C16LMPS1*AHRI reference: 218599706 | 15.20 | 8.10 | 17500 | 2.00 | EPA 4651949 → |
CTF48C5CFS2+ furnace: Z8ES100C16SMPS1*AHRI reference: 218599705 | 15.20 | 8.10 | 17500 | 2.00 | EPA 4651950 → |
CTU48C5XFS2+TXV+ furnace: Z8ES080C20LMPS1*AHRI reference: 218599704 | 15.20 | 8.10 | 17600 | 2.00 | EPA 4651951 → |
CTU48C5XFS2+TXV+ furnace: Z8ES080C20SMPS1*AHRI reference: 218599703 | 15.20 | 8.10 | 17600 | 2.00 | EPA 4651952 → |
CTF48C5CFS2+ furnace: Z8ES080C20LMPS1*AHRI reference: 218599702 | 15.20 | 8.10 | 17600 | 2.00 | EPA 4651953 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →