Kenmore / AIR-SOURCE HEAT PUMP

XH536E2S11*

LX SERIES · source records, page 2

122 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity32,400–35,000BTU/h

Each efficiency range summarizes published EPA records for XH536E2S11*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 122 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16122 / 122
EER2 · BTU/Wh11–12122 / 122
HSPF2 · BTU/Wh7.8–8.1122 / 122
Cooling capacity · BTU/h32,400–35,000122 / 122
Heating capacity at 47°F / 8.3°C · BTU/h30,600–32,600122 / 122
Heating capacity at 17°F / −8.3°C · BTU/h20,400–22,000122 / 122
Heating capacity at 5°F / −15°C · BTU/h17,000–18,400122 / 122
COP at 5°F / −15°C2–2.44122 / 122
Equipment / loop typeHP - Split System122 / 122
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)122 / 122
Compressor stagingTwo-stage122 / 122
Connected capabilityNo122 / 122

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTF48C5CFS1+ furnace: Z8VT100C20SMPC1AHRI reference: 21744505615.208.10178002.40EPA 4045182 →
CTF48C5CFS1+ furnace: Z8VT120C20SMPC1AHRI reference: 21744505815.208.10177002.42EPA 4045183 →
JHE42C5CF2SS1AHRI reference: 21694133715.208.10173002.00EPA 4498123 →
JHE36B5CD2SS1AHRI reference: 21694166115.208.10176002.00EPA 4498124 →
JHE36C5CD2SS1AHRI reference: 21694228115.207.80170002.30EPA 4570699 →
JHE36C5CD2SS2AHRI reference: 21845732215.207.80170002.30EPA 4639411 →
JHE42C5CF2SS2AHRI reference: 21845732115.208.10173002.00EPA 4639412 →
JHE36B5CD2SS2AHRI reference: 21845732015.208.10176002.00EPA 4639413 →
CTU48C5XFS2+TXV+ furnace: Z8VT120C20SMPC1AHRI reference: 21859971715.208.10177002.42EPA 4651938 →
CTM48D5CFS2+JMC20D2SN1AHRI reference: 21859971615.208.10177002.44EPA 4651939 →
CTF48C5CFS2+ furnace: Z8VT120C20SMPC1AHRI reference: 21859971515.208.10177002.42EPA 4651940 →
CTU48C5XFS2+TXV+ furnace: Z8VT100C20SMPC1AHRI reference: 21859971415.208.10178002.40EPA 4651941 →
CTF48C5CFS2+ furnace: Z8VT100C20SMPC1AHRI reference: 21859971315.208.10178002.40EPA 4651942 →
CTU48C5XFS2+TXV+ furnace: Z8ES100C16SMPS1*AHRI reference: 21859970815.208.10175002.00EPA 4651947 →
CTU48C5XFS2+TXV+ furnace: Z8ES100C16LMPS1*AHRI reference: 21859970715.208.10175002.00EPA 4651948 →
CTF48C5CFS2+ furnace: Z8ES100C16LMPS1*AHRI reference: 21859970615.208.10175002.00EPA 4651949 →
CTF48C5CFS2+ furnace: Z8ES100C16SMPS1*AHRI reference: 21859970515.208.10175002.00EPA 4651950 →
CTU48C5XFS2+TXV+ furnace: Z8ES080C20LMPS1*AHRI reference: 21859970415.208.10176002.00EPA 4651951 →
CTU48C5XFS2+TXV+ furnace: Z8ES080C20SMPS1*AHRI reference: 21859970315.208.10176002.00EPA 4651952 →
CTF48C5CFS2+ furnace: Z8ES080C20LMPS1*AHRI reference: 21859970215.208.10176002.00EPA 4651953 →