29 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8BTU/Wh
Cooling capacity33,800–36,800BTU/h

Each efficiency range summarizes published EPA records for R5H5S36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 29 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–1629 / 29
EER2 · BTU/Wh11.7–1329 / 29
HSPF2 · BTU/Wh7.8–829 / 29
Cooling capacity · BTU/h33,800–36,80029 / 29
Heating capacity at 47°F / 8.3°C · BTU/h33,200–36,40029 / 29
Heating capacity at 17°F / −8.3°C · BTU/h21,000–22,80029 / 29
Heating capacity at 5°F / −15°C · BTU/h16,100–18,10029 / 29
COP at 5°F / −15°C2–2.2229 / 29
Equipment / loop typeHP - Split System29 / 29
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)29 / 29
Compressor stagingSingle stage29 / 29
Connected capabilityNo29 / 29

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
FEVA0048**+NAVA54801CKAHRI reference: 21705165416.008.00174002.18EPA 4001123
FTMA5B48L0C*AHRI reference: 21417996015.507.80167002.18EPA 3404482
FHMA5*48L*C*AHRI reference: 21418020215.507.80174002.18EPA 3404818
FEVB0048**+NAVA54801CKAHRI reference: 21427763015.507.80174002.22EPA 3415708
FMA5X36**AL*AHRI reference: 21442430615.507.80170002.00EPA 3425193
F5MA5*48L*C*AHRI reference: 21646401515.507.80174002.18EPA 3846917
EA*5X43M21A*+ furnace: *80MS(N,L)1102120A*AHRI reference: 21413999815.207.80180002.20EPA 3400463
EA*5X48M21A*+ furnace: *95MSU1002122A*AHRI reference: 21414265215.207.80176002.18EPA 3400581
EA*5X48M21A*+ furnace: *80CTL1102120B*AHRI reference: 21414185515.207.80175002.18EPA 3400603
EA*5X48M21A*+ furnace: *80VTL0902120B*AHRI reference: 21414196515.207.80175002.18EPA 3400631
EA*5X48M21A*+ furnace: *96VTN1002122B*AHRI reference: 21414287815.207.80175002.20EPA 3400745
EVM5X44M21A*+ furnace: *80ESU0401712A*AHRI reference: 21414307015.207.80181002.14EPA 3400777
EA*5X43M21A*+ furnace: *92MSN1002120A*AHRI reference: 21414053515.207.80179002.20EPA 3400809
EA*5X48M21A*+ furnace: *80MS(N,L)0902120A*AHRI reference: 21414136215.207.80175002.18EPA 3400831
EA*5X48M21A*+ furnace: *80MS(N,L)1102120A*AHRI reference: 21414139215.207.80176002.20EPA 3400861
EA*5X48M21A*+ furnace: *92MSN1002120A*AHRI reference: 21414228115.207.80176002.18EPA 3400893
EA*5X48M21A*+ furnace: *80VSL0902120B*AHRI reference: 21414147115.207.80175002.18EPA 3400936
EA*5X43M21A*+ furnace: *80CSU0601716A*AHRI reference: 21413977715.207.80170002.18EPA 3401035
EA*5X43M21A*+ furnace: *80CSU1002120A*AHRI reference: 21413980415.207.80176002.18EPA 3401119
EA*5X37M21A*+ furnace: *80CSU0601716A*AHRI reference: 21413810515.207.80171002.16EPA 3401181

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.