Kenmore / AIR-SOURCE HEAT PUMP

N5H8T60*K*AAA*

2-STAGE 18 SEER HP · source records, page 5

121 published source records · source checked Sep 21, 2026

SEER2 range15.5–17.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity54,000–57,500BTU/h

Each efficiency range summarizes published EPA records for N5H8T60*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 121 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.5–17.5121 / 121
EER2 · BTU/Wh11.7–13121 / 121
HSPF2 · BTU/Wh7.8–8.5121 / 121
Cooling capacity · BTU/h54,000–57,500121 / 121
Heating capacity at 47°F / 8.3°C · BTU/h56,500–60,000121 / 121
Heating capacity at 17°F / −8.3°C · BTU/h36,200–38,500121 / 121
Heating capacity at 5°F / −15°C · BTU/h29,600–31,800121 / 121
COP at 5°F / −15°C2.1–2.34121 / 121
Equipment / loop typeHP - Split System121 / 121
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)121 / 121
Compressor stagingTwo-stage121 / 121
Connected capabilityNo121 / 121

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X60M24A*+ furnace: *95MSU0802120A*AHRI reference: 21562935816.008.00300002.25EPA 3951251 →
EA*5X61M21A*+ furnace: *96VTN0802120B*AHRI reference: 21562994316.008.00304002.25EPA 3951277 →
EA*5X61M21A*+ furnace: *96VTN1002120B*AHRI reference: 21562996116.008.00302002.30EPA 3951301 →
EA*5X60M24A*+ furnace: *95MSU1002120A*AHRI reference: 21562937716.008.00300002.25EPA 3951317 →
EA*5X60M24A*+ furnace: *95MSU1002122A*AHRI reference: 21562939316.008.00296002.30EPA 3951332 →
EA*5X60M24A*+ furnace: *96CTN1002122B*AHRI reference: 21562942116.008.00300002.25EPA 3951347 →
EA*5X60M24A*+ furnace: *96CTN1202422B*AHRI reference: 21562943516.008.00298002.25EPA 3951360 →
EA*5X61M24A*+ furnace: *80VSL0902120B*AHRI reference: 21563001716.008.00300002.25EPA 3951376 →
EA*5X60M24A*+ furnace: *96VTN0802120B*AHRI reference: 21562945216.008.00300002.25EPA 3951449 →
EA*5X60M24A*+ furnace: *96VTN1002120B*AHRI reference: 21562947016.008.00298002.25EPA 3951468 →
EA*5X60M24A*+ furnace: *96VTN1002122B*AHRI reference: 21562948516.008.00296002.30EPA 3951482 →
EA*5X60M24A*+ furnace: *96VTN1202422B*AHRI reference: 21562950316.008.00300002.25EPA 3951500 →
EA*5X60M24A*+ furnace: OLV154F20AAHRI reference: 21562951616.008.00302002.25EPA 3951513 →
EA*5X61M21A*+ furnace: *80VSL0902120B*AHRI reference: 21562957216.008.00300002.30EPA 3951525 →
EA*5X61M21A*+ furnace: *80MSU0601716A*AHRI reference: 21562960116.008.00304002.25EPA 3951556 →
EA*5X61M24A*+ furnace: *80CTL0702120B*AHRI reference: 21563009416.008.00306002.25EPA 3951597 →
EA*5X61M24A*+ furnace: *80VTL0902120B*AHRI reference: 21563015316.008.00300002.12EPA 3951660 →
EA*5X61M24A*+ furnace: *95CSU0802120B*AHRI reference: 21563019216.008.00304002.25EPA 3951698 →
EA*5X61M24A*+ furnace: *97CMN0802120B*AHRI reference: 21563023416.008.00302002.25EPA 3951727 →
EA*5X61M21A*+ furnace: *80MSU1002120A*AHRI reference: 21562963916.008.00302002.25EPA 3951739 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →