Kenmore / AIR-SOURCE HEAT PUMP

N5H8T48*K*AAA*

2-STAGE 18 SEER HP · source records, page 8

405 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity45,500–50,500BTU/h

Each efficiency range summarizes published EPA records for N5H8T48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 405 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18405 / 405
EER2 · BTU/Wh11.7–13.5405 / 405
HSPF2 · BTU/Wh7.8–8.5405 / 405
Cooling capacity · BTU/h45,500–50,500405 / 405
Heating capacity at 47°F / 8.3°C · BTU/h48,500–52,500405 / 405
Heating capacity at 17°F / −8.3°C · BTU/h30,000–32,600405 / 405
Heating capacity at 5°F / −15°C · BTU/h23,800–26,600405 / 405
COP at 5°F / −15°C2.06–2.32405 / 405
Equipment / loop typeHP - Split System405 / 405
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)405 / 405
Compressor stagingTwo-stage405 / 405
Connected capabilityNo405 / 405

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EVD5X48M21A*+ furnace: *80VTL0902120B*AHRI reference: 21562419916.508.10244002.12EPA 3947912
EVD5X48M21A*+ furnace: *80VTL1102122B*AHRI reference: 21562421516.508.10242002.14EPA 3947927
EVM5X49M21A*+ furnace: *96CTN0802120B*AHRI reference: 21562358116.508.10252002.10EPA 3947965
EVM5X49M21A*+ furnace: *96VTN0802120B*AHRI reference: 21562361216.508.10250002.12EPA 3947995
EVM5X60M21A*+ furnace: *96VTN0802120B*AHRI reference: 21562401016.508.10248002.12EPA 3948022
EVM5X60M21A*+ furnace: *96VTN1002120B*AHRI reference: 21562402816.508.10246002.14EPA 3948025
EVD5X48M21A*+ furnace: *80VSL0902120B*AHRI reference: 21562407016.508.10244002.12EPA 3948063
EVD5X48M21A*+ furnace: *80MSU1002120A*AHRI reference: 21562412416.508.10246002.12EPA 3948115
EVM5X49M21A*+ furnace: *96VTN1002120B*AHRI reference: 21562363016.508.10250002.10EPA 3948119
EVD5X48M21A*+ furnace: *95CSU1002122B*AHRI reference: 21562424416.508.10246002.14EPA 3948210
EVD5X48M21A*+ furnace: *97CMN1002122B*AHRI reference: 21562428616.508.10244002.12EPA 3948237
EVM5X60M21A*+ furnace: *80CTL0702120B*AHRI reference: 21562375516.508.10256002.08EPA 3948316
EVM5X60M21A*+ furnace: *95CSU0802120B*AHRI reference: 21562383116.508.10252002.10EPA 3948393
EVD5X48M21A*+ furnace: *96VSN1002120B*AHRI reference: 21562431316.508.10244002.12EPA 3948408
EVD5X48M21A*+ furnace: *95MSU1002120A*AHRI reference: 21562432916.508.10244002.12EPA 3948423
EVD5X48M21A*+ furnace: *95MSU1002122A*AHRI reference: 21562434516.508.10242002.16EPA 3948439
EVM5X60M21A*+ furnace: *97CMN0802120B*AHRI reference: 21562387316.508.10252002.08EPA 3948486
EVM5X60M21A*+ furnace: *96VSN0802120B*AHRI reference: 21562390116.508.10248002.12EPA 3948512
EVM5X60M21A*+ furnace: *96VSN1002120B*AHRI reference: 21562391416.508.10248002.12EPA 3948524
EVD5X48M21A*+ furnace: *80MSU0601716A*AHRI reference: 21562408616.508.10242002.14EPA 3948541

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →