Kenmore / AIR-SOURCE HEAT PUMP

N5H8T48*K*AAA*

2-STAGE 18 SEER HP · source records, page 8

405 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity45,500–50,500BTU/h

Each efficiency range summarizes published EPA records for N5H8T48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 405 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18405 / 405
EER2 · BTU/Wh11.7–13.5405 / 405
HSPF2 · BTU/Wh7.8–8.5405 / 405
Cooling capacity · BTU/h45,500–50,500405 / 405
Heating capacity at 47°F / 8.3°C · BTU/h48,500–52,500405 / 405
Heating capacity at 17°F / −8.3°C · BTU/h30,000–32,600405 / 405
Heating capacity at 5°F / −15°C · BTU/h23,800–26,600405 / 405
COP at 5°F / −15°C2.06–2.32405 / 405
Equipment / loop typeHP - Split System405 / 405
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)405 / 405
Compressor stagingTwo-stage405 / 405
Connected capabilityNo405 / 405

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EVD5X48M21A*+ furnace: *80VTL0902120B*AHRI reference: 21562419916.508.10244002.12EPA 3947912 →
EVD5X48M21A*+ furnace: *80VTL1102122B*AHRI reference: 21562421516.508.10242002.14EPA 3947927 →
EVM5X49M21A*+ furnace: *96CTN0802120B*AHRI reference: 21562358116.508.10252002.10EPA 3947965 →
EVM5X49M21A*+ furnace: *96VTN0802120B*AHRI reference: 21562361216.508.10250002.12EPA 3947995 →
EVM5X60M21A*+ furnace: *96VTN0802120B*AHRI reference: 21562401016.508.10248002.12EPA 3948022 →
EVM5X60M21A*+ furnace: *96VTN1002120B*AHRI reference: 21562402816.508.10246002.14EPA 3948025 →
EVD5X48M21A*+ furnace: *80VSL0902120B*AHRI reference: 21562407016.508.10244002.12EPA 3948063 →
EVD5X48M21A*+ furnace: *80MSU1002120A*AHRI reference: 21562412416.508.10246002.12EPA 3948115 →
EVM5X49M21A*+ furnace: *96VTN1002120B*AHRI reference: 21562363016.508.10250002.10EPA 3948119 →
EVD5X48M21A*+ furnace: *95CSU1002122B*AHRI reference: 21562424416.508.10246002.14EPA 3948210 →
EVD5X48M21A*+ furnace: *97CMN1002122B*AHRI reference: 21562428616.508.10244002.12EPA 3948237 →
EVM5X60M21A*+ furnace: *80CTL0702120B*AHRI reference: 21562375516.508.10256002.08EPA 3948316 →
EVM5X60M21A*+ furnace: *95CSU0802120B*AHRI reference: 21562383116.508.10252002.10EPA 3948393 →
EVD5X48M21A*+ furnace: *96VSN1002120B*AHRI reference: 21562431316.508.10244002.12EPA 3948408 →
EVD5X48M21A*+ furnace: *95MSU1002120A*AHRI reference: 21562432916.508.10244002.12EPA 3948423 →
EVD5X48M21A*+ furnace: *95MSU1002122A*AHRI reference: 21562434516.508.10242002.16EPA 3948439 →
EVM5X60M21A*+ furnace: *97CMN0802120B*AHRI reference: 21562387316.508.10252002.08EPA 3948486 →
EVM5X60M21A*+ furnace: *96VSN0802120B*AHRI reference: 21562390116.508.10248002.12EPA 3948512 →
EVM5X60M21A*+ furnace: *96VSN1002120B*AHRI reference: 21562391416.508.10248002.12EPA 3948524 →
EVD5X48M21A*+ furnace: *80MSU0601716A*AHRI reference: 21562408616.508.10242002.14EPA 3948541 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →