Kenmore / AIR-SOURCE HEAT PUMP

N5H8T48*K*AAA*

2-STAGE 18 SEER HP · source records, page 10

405 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity45,500–50,500BTU/h

Each efficiency range summarizes published EPA records for N5H8T48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 405 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18405 / 405
EER2 · BTU/Wh11.7–13.5405 / 405
HSPF2 · BTU/Wh7.8–8.5405 / 405
Cooling capacity · BTU/h45,500–50,500405 / 405
Heating capacity at 47°F / 8.3°C · BTU/h48,500–52,500405 / 405
Heating capacity at 17°F / −8.3°C · BTU/h30,000–32,600405 / 405
Heating capacity at 5°F / −15°C · BTU/h23,800–26,600405 / 405
COP at 5°F / −15°C2.06–2.32405 / 405
Equipment / loop typeHP - Split System405 / 405
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)405 / 405
Compressor stagingTwo-stage405 / 405
Connected capabilityNo405 / 405

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EVD5X61M21A*+ furnace: *80CTL0702120B*AHRI reference: 21562510416.508.10256002.08EPA 3949319 →
EVD5X61M24A*+ furnace: *95MSU0802120A*AHRI reference: 21562563116.508.10252002.12EPA 3949405 →
EVD5X61M21A*+ furnace: *95MSU0802120A*AHRI reference: 21562526516.508.10252002.10EPA 3949566 →
EVD5X61M24A*+ furnace: *95CSU0802120B*AHRI reference: 21562553316.508.10256002.08EPA 3949650 →
EVD5X61M24A*+ furnace: *97CMN1202422B*AHRI reference: 21562557516.508.10252002.12EPA 3949679 →
EVD5X61M24A*+ furnace: *80CTL0702120B*AHRI reference: 21562544916.508.10256002.10EPA 3949786 →
EVD5X61M24A*+ furnace: *96CTN0802120B*AHRI reference: 21562568016.508.10256002.10EPA 3950005 →
EVD5X61M24A*+ furnace: *96VTN1202422B*AHRI reference: 21562577616.508.10252002.12EPA 3950170 →
EVD5X48M21A*+ furnace: *80VSL1102122B*AHRI reference: 21562884916.508.10242002.14EPA 3950389 →
EVD5X61M21A*+TDRAHRI reference: 21562870616.508.10242002.16EPA 3950477 →
EVD5X61M24A*+TDRAHRI reference: 21562872516.508.10242002.16EPA 3950498 →
EA*5X61M21A*+ furnace: *96VTN1002122B*AHRI reference: 21562883616.508.10252002.24EPA 3950513 →
EVD5X60M21A*+TDRAHRI reference: 21562866816.508.00240002.15EPA 3950639 →
EVM5X49M21A*+TDRAHRI reference: 21562853516.508.00240002.15EPA 3950772 →
EVM5X60M21A*+TDRAHRI reference: 21562855416.508.00240002.15EPA 3950791 →
EVM5X61M24A*+TDRAHRI reference: 21562859216.508.10242002.16EPA 3950832 →
EA*5X60M24A*+ furnace: *80MSU0802120A*AHRI reference: 21563186616.508.10256002.20EPA 3952586 →
EA*5X61M21A*+ furnace: *80MSU1002120A*AHRI reference: 21563241916.508.10258002.22EPA 3952727 →
EA*5X61M21A*+ furnace: *80CTL0902120B*AHRI reference: 21563247716.508.10254002.22EPA 3952774 →
EA*5X61M21A*+ furnace: *80CTL1102120B*AHRI reference: 21563249116.508.10258002.20EPA 3952787 →