Kenmore / AIR-SOURCE HEAT PUMP

N5H8T36*K*AAA*

2-STAGE 18 SEER HP · source records, page 4

254 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity33,800–37,600BTU/h

Each efficiency range summarizes published EPA records for N5H8T36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 254 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17254 / 254
EER2 · BTU/Wh11.7–13254 / 254
HSPF2 · BTU/Wh7.8–8.5254 / 254
Cooling capacity · BTU/h33,800–37,600254 / 254
Heating capacity at 47°F / 8.3°C · BTU/h37,200–39,000254 / 254
Heating capacity at 17°F / −8.3°C · BTU/h23,000–24,200254 / 254
Heating capacity at 5°F / −15°C · BTU/h17,500–19,600254 / 254
COP at 5°F / −15°C1.78–2.48254 / 254
Equipment / loop typeHP - Split System254 / 254
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)254 / 254
Compressor stagingTwo-stage254 / 254
Connected capabilityNo254 / 254

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EVD5X48M21A*+ furnace: *80VSL1102122B*AHRI reference: 21562248615.507.80177001.78EPA 3947140
EVD5X48M21A*+ furnace: *80MSU0601716A*AHRI reference: 21562250215.507.80177001.78EPA 3947156
EVD5X48M21A*+ furnace: *80MSU0802120A*AHRI reference: 21562252115.507.80175001.80EPA 3947169
EVD5X48M21A*+ furnace: *80CTL1102120B*AHRI reference: 21562261215.507.80177001.80EPA 3947187
EVD5X48M21A*+ furnace: *80VTL0902120B*AHRI reference: 21562265515.507.80177001.80EPA 3947212
EVD5X48M21A*+ furnace: *95CSU1002122B*AHRI reference: 21562268215.507.80178001.78EPA 3947225
EVD5X48M21A*+ furnace: *96CTN0802120B*AHRI reference: 21562280015.507.80178001.78EPA 3947261
EVD5X48M21A*+ furnace: *96VTN1002122B*AHRI reference: 21562289015.507.80176001.80EPA 3947308
EA*5X37M17A*+ furnace: *80CSU0401712A*AHRI reference: 21563513915.508.10189002.28EPA 3954416
EA*5X37M17A*+ furnace: *80VSL0901716B*AHRI reference: 21563520615.508.10189002.28EPA 3954549
EA*5X37M21A*+ furnace: *80VSL0901716B*AHRI reference: 21563566715.508.10193002.26EPA 3954568
EA*5X37M21A*+ furnace: *80VSL0902120B*AHRI reference: 21563568015.508.10193002.26EPA 3954580
EA*5X37M21A*+ furnace: *80MSU0401712A*AHRI reference: 21563570915.508.10193002.26EPA 3954602
EA*5X37M21A*+ furnace: *80MSU0802120A*AHRI reference: 21563574315.508.10191002.42EPA 3954635
EA*5X37M21A*+ furnace: *80MSU1002120A*AHRI reference: 21563576015.508.10194002.26EPA 3954656
EA*5X37M21A*+ furnace: *80CTL0702120B*AHRI reference: 21563580215.508.10194002.24EPA 3954684
EA*5X37M21A*+ furnace: *80CTL0901716B*AHRI reference: 21563581615.508.10194002.24EPA 3954697
EA*5X37M21A*+ furnace: *80CTL0902120B*AHRI reference: 21563583015.508.10193002.26EPA 3954708
EA*5X37M21A*+ furnace: *80CTL1102120B*AHRI reference: 21563584415.508.10193002.24EPA 3954728
EA*5X37M21A*+ furnace: *80VTL0902120B*AHRI reference: 21563588515.508.10193002.26EPA 3954753

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →