Kenmore / AIR-SOURCE HEAT PUMP

N5H8T36*K*AAA*

2-STAGE 18 SEER HP · source records, page 11

254 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity33,800–37,600BTU/h

Each efficiency range summarizes published EPA records for N5H8T36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 254 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17254 / 254
EER2 · BTU/Wh11.7–13254 / 254
HSPF2 · BTU/Wh7.8–8.5254 / 254
Cooling capacity · BTU/h33,800–37,600254 / 254
Heating capacity at 47°F / 8.3°C · BTU/h37,200–39,000254 / 254
Heating capacity at 17°F / −8.3°C · BTU/h23,000–24,200254 / 254
Heating capacity at 5°F / −15°C · BTU/h17,500–19,600254 / 254
COP at 5°F / −15°C1.78–2.48254 / 254
Equipment / loop typeHP - Split System254 / 254
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)254 / 254
Compressor stagingTwo-stage254 / 254
Connected capabilityNo254 / 254

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X42M21A*+ furnace: *95MSU1002122A*AHRI reference: 21563734115.208.10188002.24EPA 3955394 →
EA*5X42M21A*+ furnace: *96CTN1002122B*AHRI reference: 21563742915.208.10188002.24EPA 3955409 →
EA*5X43M21A*+ furnace: *80CSU0401712A*AHRI reference: 21563760915.208.10196002.24EPA 3955434 →
EA*5X43M21A*+ furnace: *80CSU0802120A*AHRI reference: 21563764815.208.10195002.24EPA 3955446 →
EA*5X43M21A*+ furnace: *80CTL0701716B*AHRI reference: 21563788315.208.10195002.24EPA 3955611 →
EA*5X43M21A*+ furnace: *96VSN0801716B*AHRI reference: 21563826415.208.10196002.24EPA 3955645 →
EA*5X43M21A*+ furnace: *96VTN0801716B*AHRI reference: 21563855515.208.10196002.24EPA 3955667 →
EA*5X43M21A*+ furnace: *95MSU0601716A*AHRI reference: 21563833015.208.10196002.22EPA 3955714 →
EA*5X48M21A*+ furnace: *80VSL0901716B*AHRI reference: 21563878015.208.10191002.26EPA 3955800 →
EA*5X43M21A*+ furnace: *95CSU0601716B*AHRI reference: 21563807815.208.10194002.24EPA 3955912 →
EA*5X43M21A*+ furnace: *97CMN0801714B*AHRI reference: 21563818315.208.10195002.24EPA 3955956 →
EA*5X43M21A*+ furnace: *96CTN0801714B*AHRI reference: 21563845315.208.10194002.24EPA 3956043 →
EA*5X48M21A*+ furnace: *80CSU0401712A*AHRI reference: 21563869515.208.10193002.22EPA 3956077 →
EA*5X48M21A*+ furnace: *80CSU0802120A*AHRI reference: 21563873915.208.10192002.24EPA 3956092 →
EA*5X48M21A*+ furnace: *80VSL0701716B*AHRI reference: 21563876015.208.10192002.24EPA 3956106 →
EA*5X48M21A*+ furnace: *80CTL0701716B*AHRI reference: 21563897315.208.10193002.24EPA 3956170 →
EA*5X48M21A*+ furnace: *80CTL0702120B*AHRI reference: 21563899515.208.10192002.26EPA 3956184 →
EA*5X48M21A*+ furnace: *80CTL0901716B*AHRI reference: 21563901615.208.10191002.26EPA 3956199 →
EA*5X48M21A*+ furnace: *80VTL0701716B*AHRI reference: 21563908015.208.10193002.24EPA 3956210 →
EA*5X48M21A*+ furnace: *95CSU0802120B*AHRI reference: 21563919015.208.10192002.26EPA 3956298 →