Kenmore / AIR-SOURCE HEAT PUMP

N5H8T36*K*AAA*

2-STAGE 18 SEER HP

254 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity33,800–37,600BTU/h

Each efficiency range summarizes published EPA records for N5H8T36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 254 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17254 / 254
EER2 · BTU/Wh11.7–13254 / 254
HSPF2 · BTU/Wh7.8–8.5254 / 254
Cooling capacity · BTU/h33,800–37,600254 / 254
Heating capacity at 47°F / 8.3°C · BTU/h37,200–39,000254 / 254
Heating capacity at 17°F / −8.3°C · BTU/h23,000–24,200254 / 254
Heating capacity at 5°F / −15°C · BTU/h17,500–19,600254 / 254
COP at 5°F / −15°C1.78–2.48254 / 254
Equipment / loop typeHP - Split System254 / 254
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)254 / 254
Compressor stagingTwo-stage254 / 254
Connected capabilityNo254 / 254

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
FTMA5B60L0D*AHRI reference: 21562895617.008.50186002.48EPA 3950957 →
FTMA5B48L0C*AHRI reference: 21562890216.508.10187002.30EPA 3950443 →
EVM5X48M21A*+ furnace: *80MSU0802120A*AHRI reference: 21561954616.008.00175001.90EPA 3946340 →
EVM5X49M21A*+ furnace: *80VSL0902120B*AHRI reference: 21561989416.008.00179001.90EPA 3946550 →
EVM5X49M21A*+ furnace: *80MSU0802120A*AHRI reference: 21561991016.008.00177001.95EPA 3946566 →
EVM5X49M21A*+ furnace: *80VTL0902120B*AHRI reference: 21561998316.008.00179001.90EPA 3946638 →
EVM5X49M21A*+ furnace: *95CSU1002122B*AHRI reference: 21562001016.008.00179001.95EPA 3946654 →
EVM5X49M21A*+ furnace: *96CTN0802120B*AHRI reference: 21562005116.007.80179001.80EPA 3946666 →
EVM5X49M21A*+ furnace: *96VTN1002120B*AHRI reference: 21562009016.008.00179001.90EPA 3946685 →
EVD5X38M17A*+ furnace: *80VSL0901716B*AHRI reference: 21562131916.008.00176001.90EPA 3946870 →
EVD5X38M17A*+ furnace: *80MSU0401712A*AHRI reference: 21562133516.008.00176001.85EPA 3946887 →
EVD5X38M17A*+ furnace: *80MSU0601716A*AHRI reference: 21562135416.008.00176001.90EPA 3946905 →
EVD5X38M17A*+ furnace: *80CTL0901716B*AHRI reference: 21562141216.007.80176001.80EPA 3946936 →
EA*5X37M21A*+ furnace: *80VSL1102122B*AHRI reference: 21563569316.008.10194002.24EPA 3954587 →
EA*5X37M21A*+ furnace: *80MSU0601716A*AHRI reference: 21563572616.008.10193002.26EPA 3954619 →
EA*5X37M21A*+ furnace: *95MSU1002122A*AHRI reference: 21563615416.008.10194002.26EPA 3955070 →
EA*5X37M21A*+ furnace: *96VTN1002122B*AHRI reference: 21563638516.008.10192002.40EPA 3955146 →
EA*5X43M21A*+ furnace: *80VSL1102122B*AHRI reference: 21563772716.008.10192002.40EPA 3955500 →
EA*5X43M21A*+ furnace: *80MSU0601716A*AHRI reference: 21563777716.008.10193002.26EPA 3955536 →
EA*5X43M21A*+ furnace: *80MSU0802120A*AHRI reference: 21563780616.008.50191002.40EPA 3955556 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →