Kenmore / AIR-SOURCE HEAT PUMP

N5H8T24*K*AAA*

2-STAGE 18 SEER HP · source records, page 6

512 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for N5H8T24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 512 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5512 / 512
EER2 · BTU/Wh11.5–14512 / 512
HSPF2 · BTU/Wh7.8–8.5512 / 512
Cooling capacity · BTU/h22,200–25,000512 / 512
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,400512 / 512
Heating capacity at 17°F / −8.3°C · BTU/h14,100–15,000512 / 512
Heating capacity at 5°F / −15°C · BTU/h10,700–11,500512 / 512
COP at 5°F / −15°C1.9–2.24512 / 512
Equipment / loop typeHP - Split System512 / 512
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)512 / 512
Compressor stagingTwo-stage512 / 512
Connected capabilityNo512 / 512

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X37M17A*+ furnace: *97CMN0801714B*AHRI reference: 21564733117.508.10111002.08EPA 3960026
EA*5X37M17A*+ furnace: *96VTN0801716B*AHRI reference: 21564767617.508.10111002.08EPA 3960110
EA*5X37M17A*+ furnace: *96CTN0601714B*AHRI reference: 21564752417.508.10111002.08EPA 3960218
EA*5X37M17A*+ furnace: *96CTN0801714B*AHRI reference: 21564754417.508.10110002.10EPA 3960239
EA*5X37M17A*+ furnace: *96VSN0801716B*AHRI reference: 21564742717.508.10111002.08EPA 3960357
EA*5X37M21A*+ furnace: *80CTL0902120B*AHRI reference: 21564804217.508.10111002.10EPA 3960620
EA*5X37M21A*+ furnace: *80CTL1102120B*AHRI reference: 21564806317.508.10111002.10EPA 3960642
EA*5X37M21A*+ furnace: *80VSL0701716B*AHRI reference: 21564778217.508.10111002.10EPA 3960765
EA*5X37M21A*+ furnace: *80VSL0902120B*AHRI reference: 21564782117.508.10111002.10EPA 3960788
EA*5X37M21A*+ furnace: *80MSU1002120A*AHRI reference: 21564794217.508.10111002.10EPA 3961007
EA*5X37M21A*+ furnace: *80CTL0451712B*AHRI reference: 21564796217.508.10112002.08EPA 3961024
EA*5X37M21A*+ furnace: *80CTL0702120B*AHRI reference: 21564800117.508.10111002.10EPA 3961046
EA*5X37M21A*+ furnace: *96CTN1002122B*AHRI reference: 21564861017.508.10111002.10EPA 3961076
EA*5X37M21A*+ furnace: *80VTL0902120B*AHRI reference: 21564812517.508.10111002.10EPA 3961261
EA*5X37M21A*+ furnace: *95CSU0601716B*AHRI reference: 21564816717.508.10111002.10EPA 3961286
EA*5X37M21A*+ furnace: *95CSU0802120B*AHRI reference: 21564818717.508.10112002.10EPA 3961302
EA*5X37M21A*+ furnace: *95CSU1002122B*AHRI reference: 21564820817.508.10111002.10EPA 3961313
EA*5X37M21A*+ furnace: *97CMN0601714B*AHRI reference: 21564822917.508.10112002.10EPA 3961331
EA*5X37M21A*+ furnace: *97CMN0602120B*AHRI reference: 21564824917.508.50112002.10EPA 3961343
EA*5X37M21A*+ furnace: *97CMN0801714B*AHRI reference: 21564826917.508.10112002.08EPA 3961354

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →