Kenmore / AIR-SOURCE HEAT PUMP

N5H8T24*K*AAA*

2-STAGE 18 SEER HP · source records, page 4

512 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for N5H8T24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 512 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5512 / 512
EER2 · BTU/Wh11.5–14512 / 512
HSPF2 · BTU/Wh7.8–8.5512 / 512
Cooling capacity · BTU/h22,200–25,000512 / 512
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,400512 / 512
Heating capacity at 17°F / −8.3°C · BTU/h14,100–15,000512 / 512
Heating capacity at 5°F / −15°C · BTU/h10,700–11,500512 / 512
COP at 5°F / −15°C1.9–2.24512 / 512
Equipment / loop typeHP - Split System512 / 512
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)512 / 512
Compressor stagingTwo-stage512 / 512
Connected capabilityNo512 / 512

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EVM5X31M17A*+ furnace: *80VSL0451412B*AHRI reference: 21561383417.507.80109001.98EPA 3945998 →
EA*5X25M17A*+ furnace: *80VSL0451412B*AHRI reference: 21564439617.508.10110002.10EPA 3957787 →
EA*5X25M17A*+ furnace: *80VSL0901716B*AHRI reference: 21564445517.508.10111002.10EPA 3957826 →
EA*5X25M17A*+ furnace: *80MSU0601716A*AHRI reference: 21564450617.508.10110002.10EPA 3957863 →
EA*5X25M17A*+ furnace: *80CTL0701716B*AHRI reference: 21564457117.508.10111002.10EPA 3957900 →
EA*5X25M17A*+ furnace: *80CTL0901716B*AHRI reference: 21564459117.508.10111002.10EPA 3957919 →
EA*5X25M17A*+ furnace: *80VTL0451412B*AHRI reference: 21564461617.508.10110002.10EPA 3957938 →
EA*5X25M17A*+ furnace: *80VTL0701716B*AHRI reference: 21564466017.508.10111002.10EPA 3957970 →
EA*5X25M17A*+ furnace: *95CSU0601716B*AHRI reference: 21564469617.508.10111002.10EPA 3957986 →
EA*5X25M17A*+ furnace: *97CMN0601714B*AHRI reference: 21564471717.508.10111002.08EPA 3958002 →
EA*5X25M17A*+ furnace: *97CMN0801714B*AHRI reference: 21564473717.508.10111002.08EPA 3958015 →
EA*5X25M17A*+ furnace: *96VTN0801716B*AHRI reference: 21564509117.508.10111002.08EPA 3958045 →
EA*5X25M17A*+ furnace: *96VSN0601716B*AHRI reference: 21564481717.508.10112002.08EPA 3958077 →
EA*5X25M17A*+ furnace: *96VSN0801716B*AHRI reference: 21564483617.508.10111002.08EPA 3958097 →
EA*5X25M17A*+ furnace: *95MSU0601716A*AHRI reference: 21564488717.508.10111002.10EPA 3958131 →
EA*5X25M17A*+ furnace: *96CTN0601714B*AHRI reference: 21564493417.508.10111002.08EPA 3958160 →
EA*5X25M17A*+ furnace: *96CTN0801714B*AHRI reference: 21564495617.508.10111002.10EPA 3958173 →
EA*5X25M17A*+ furnace: *96VTN0601716B*AHRI reference: 21564506117.508.10112002.08EPA 3958246 →
EA*5X25M17A*+ furnace: OMV098J12*AHRI reference: 21564513417.508.10111002.10EPA 3958282 →
EA*5X25M17A*+ furnace: OMV112K14AAHRI reference: 21564515717.508.10115002.04EPA 3958296 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →