Kenmore / AIR-SOURCE HEAT PUMP

N5H8T24*K*AAA*

2-STAGE 18 SEER HP · source records, page 24

512 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for N5H8T24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 512 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5512 / 512
EER2 · BTU/Wh11.5–14512 / 512
HSPF2 · BTU/Wh7.8–8.5512 / 512
Cooling capacity · BTU/h22,200–25,000512 / 512
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,400512 / 512
Heating capacity at 17°F / −8.3°C · BTU/h14,100–15,000512 / 512
Heating capacity at 5°F / −15°C · BTU/h10,700–11,500512 / 512
COP at 5°F / −15°C1.9–2.24512 / 512
Equipment / loop typeHP - Split System512 / 512
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)512 / 512
Compressor stagingTwo-stage512 / 512
Connected capabilityNo512 / 512

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
ESH5X24M12A*+ furnace: *96CTN1202422B*AHRI reference: 21564998216.008.00111002.05EPA 3997262 →
ESH5X24M12A*+ furnace: *97VTN1202422A*AHRI reference: 21571308016.008.00111002.05EPA 3997330 →
ESH5X24M12A*+ furnace: *80CTL0902120B*AHRI reference: 21564920616.008.00111002.05EPA 3997336 →
ESH5X24M12A*+ furnace: *97VTN0802120A*AHRI reference: 21571303216.008.00111002.05EPA 3997356 →
ESH5X24M12A*+ furnace: *96VTN0802120B*AHRI reference: 21565013916.008.00111002.05EPA 3997362 →
ESH5X24M12A*+ furnace: *80CTL0901716B*AHRI reference: 21564918616.008.00111002.05EPA 3997369 →
ESH5X24M12A*+ furnace: *80CTL0701716B*AHRI reference: 21564914616.008.00111002.05EPA 3997384 →
ESH5X24M12A*+ furnace: *80CTL0451712B*AHRI reference: 21564910516.008.00111002.05EPA 3997405 →
ESH5X30M12A*+ furnace: *97CMN0602120B*AHRI reference: 21565094716.008.00111002.05EPA 3997414 →
ESH5X30M12A*+ furnace: *96VTN0401410B*AHRI reference: 21565147116.008.00114002.05EPA 3997429 →
ESH5X24M12A*+ furnace: *80MSU0401712A*AHRI reference: 21564899416.007.80110002.05EPA 3997449 →
ESH5X24M12A*+ furnace: *80VSL1352422B*AHRI reference: 21564897016.008.00112002.05EPA 3997463 →
ESH5X30M12A*+ furnace: *97CTN0601716A*AHRI reference: 21571309316.008.00112002.05EPA 3997479 →
ESH5X24M12A*+ furnace: *80VSL0902120B*AHRI reference: 21564893316.008.00111002.05EPA 3997490 →
ESH5X24M12A*+ furnace: *80VSL0901716B*AHRI reference: 21564891416.008.00111002.05EPA 3997503 →
ESH5X30M12A*+ furnace: *97CMN0601714B*AHRI reference: 21565092516.008.00111002.05EPA 3997587 →
ESH5X30M12A*+ furnace: *95MSU0401712A*AHRI reference: 21565120916.008.00111002.05EPA 3997607 →
ESH5X30M12A*+ furnace: *96VSN0401410B*AHRI reference: 21565105016.008.00113002.05EPA 3997622 →
EA*5X30M14A*+ furnace: *96CTN0401410B*AHRI reference: 21564531816.008.00111002.00EPA 3997635 →
EA*5X36M17A*+ furnace: *97CTN0401410A*AHRI reference: 21799192816.008.00113002.02EPA 4566275 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →