Kenmore / AIR-SOURCE HEAT PUMP

N5H8T24*K*AAA*

2-STAGE 18 SEER HP · source records, page 20

512 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for N5H8T24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 512 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5512 / 512
EER2 · BTU/Wh11.5–14512 / 512
HSPF2 · BTU/Wh7.8–8.5512 / 512
Cooling capacity · BTU/h22,200–25,000512 / 512
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,400512 / 512
Heating capacity at 17°F / −8.3°C · BTU/h14,100–15,000512 / 512
Heating capacity at 5°F / −15°C · BTU/h10,700–11,500512 / 512
COP at 5°F / −15°C1.9–2.24512 / 512
Equipment / loop typeHP - Split System512 / 512
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)512 / 512
Compressor stagingTwo-stage512 / 512
Connected capabilityNo512 / 512

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X30M17A*+ furnace: *96VSN0401410B*AHRI reference: 21564577416.008.00112002.00EPA 3958793 →
EA*5X30M17A*+ furnace: *96VSN0401712B*AHRI reference: 21564579316.008.10112001.90EPA 3958808 →
EA*5X30M17A*+ furnace: *96VTN0401410B*AHRI reference: 21564599716.008.00112002.00EPA 3958998 →
EA*5X36M17A*+ furnace: *96VSN0401410B*AHRI reference: 21564656416.008.00112002.05EPA 3959266 →
EA*5X36M17A*+ furnace: *96CTN0401410B*AHRI reference: 21564671416.008.00113002.00EPA 3959455 →
EA*5X36M17A*+ furnace: *96VTN0401410B*AHRI reference: 21564678216.008.00112002.00EPA 3959505 →
EA*5X37M17A*+ furnace: *96CTN0401410B*AHRI reference: 21564750116.008.10113002.04EPA 3960203 →
ESH5X24M12A*+ furnace: *80CSU0401712A*AHRI reference: 21564883516.007.80113002.04EPA 3961787 →
ESH5X24M12A*+ furnace: *80VSL0451412B*AHRI reference: 21564885716.007.80110001.94EPA 3961798 →
ESH5X24M12A*+ furnace: *80VSL1102122B*AHRI reference: 21564895116.008.00112002.05EPA 3962058 →
ESH5X24M12A*+ furnace: *80MSU1002120A*AHRI reference: 21564908016.007.80111002.00EPA 3962067 →
ESH5X24M12A*+ furnace: *80VTL0451412B*AHRI reference: 21564927016.007.80110001.94EPA 3962096 →
ESH5X24M12A*+ furnace: *80VTL0701716B*AHRI reference: 21564931316.007.80111001.92EPA 3962111 →
ESH5X24M12A*+ furnace: *96VSN0601412B*AHRI reference: 21564963416.008.00111002.05EPA 3962144 →
ESH5X24M12A*+ furnace: *96VSN0601716B*AHRI reference: 21564965216.008.00111002.05EPA 3962164 →
ESH5X24M12A*+ furnace: *96VSN0801716B*AHRI reference: 21564967216.007.80110001.94EPA 3962173 →
ESH5X24M12A*+ furnace: *96VSN1002120B*AHRI reference: 21564970816.008.00112002.05EPA 3962179 →
ESH5X24M12A*+ furnace: *96VSN1202422B*AHRI reference: 21564972716.007.80111001.94EPA 3962195 →
ESH5X24M12A*+ furnace: *96VTN0601412B*AHRI reference: 21565005716.008.00111002.05EPA 3962272 →
ESH5X24M12A*+ furnace: *96VTN0601716B*AHRI reference: 21565008316.008.00111002.05EPA 3962294 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →