Kenmore / AIR-SOURCE HEAT PUMP

N5H8T24*K*AAA*

2-STAGE 18 SEER HP · source records, page 2

512 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for N5H8T24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 512 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5512 / 512
EER2 · BTU/Wh11.5–14512 / 512
HSPF2 · BTU/Wh7.8–8.5512 / 512
Cooling capacity · BTU/h22,200–25,000512 / 512
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,400512 / 512
Heating capacity at 17°F / −8.3°C · BTU/h14,100–15,000512 / 512
Heating capacity at 5°F / −15°C · BTU/h10,700–11,500512 / 512
COP at 5°F / −15°C1.9–2.24512 / 512
Equipment / loop typeHP - Split System512 / 512
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)512 / 512
Compressor stagingTwo-stage512 / 512
Connected capabilityNo512 / 512

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EVD5X38M17A*+ furnace: OMV112K14AAHRI reference: 21561899818.008.00112002.10EPA 3946236 →
EVD5X31M17A*+ furnace: *80VSL0701716B*AHRI reference: 21561632118.008.00111002.10EPA 3946238 →
EVD5X31M17A*+ furnace: *80VTL0451412B*AHRI reference: 21561641118.007.80110001.98EPA 3946375 →
EVD5X31M17A*+ furnace: *96CTN0601714B*AHRI reference: 21561656118.007.80112001.96EPA 3946391 →
EA*5X25M17A*+ furnace: *80CSU0401712A*AHRI reference: 21564437618.008.50113002.20EPA 3957773 →
EA*5X25M17A*+ furnace: *80VSL0701412B*AHRI reference: 21564441418.008.10110002.10EPA 3957796 →
EA*5X25M17A*+ furnace: *80VSL0701716B*AHRI reference: 21564443318.008.10111002.10EPA 3957818 →
EA*5X25M17A*+ furnace: *80MSU0401712A*AHRI reference: 21564447818.008.10111002.10EPA 3957841 →
EA*5X25M17A*+ furnace: *80CTL0701412B*AHRI reference: 21564455118.008.10111002.10EPA 3957896 →
EA*5X37M21A*+ furnace: *80CTL0901716B*AHRI reference: 21564802218.008.10111002.10EPA 3960610 →
EA*5X37M21A*+ furnace: *80VTL0701716B*AHRI reference: 21564808818.008.10111002.10EPA 3960659 →
EA*5X37M21A*+ furnace: *80CSU0401712A*AHRI reference: 21564776218.008.50113002.20EPA 3960750 →
EA*5X37M21A*+ furnace: *80VSL0901716B*AHRI reference: 21564780118.008.10111002.10EPA 3960778 →
EA*5X37M21A*+ furnace: *80VSL1102122B*AHRI reference: 21564784118.008.50111002.22EPA 3960872 →
EA*5X37M21A*+ furnace: *80MSU0401712A*AHRI reference: 21564786318.008.50111002.24EPA 3960893 →
EA*5X37M21A*+ furnace: *80MSU0601716A*AHRI reference: 21564788818.008.50112002.24EPA 3960904 →
EA*5X37M21A*+ furnace: *80MSU0802120A*AHRI reference: 21564791418.008.50111002.24EPA 3960922 →
EA*5X37M21A*+ furnace: *80CTL0701716B*AHRI reference: 21564798218.008.10111002.10EPA 3961034 →
EA*5X37M21A*+ furnace: *96VTN0601716B*AHRI reference: 21564866218.008.10112002.10EPA 3961114 →
EA*5X37M21A*+ furnace: *80VTL1102122B*AHRI reference: 21564814818.008.50112002.22EPA 3961271 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →