Kenmore / AIR-SOURCE HEAT PUMP

N5H8T24*K*AAA*

2-STAGE 18 SEER HP · source records, page 16

512 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for N5H8T24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 512 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5512 / 512
EER2 · BTU/Wh11.5–14512 / 512
HSPF2 · BTU/Wh7.8–8.5512 / 512
Cooling capacity · BTU/h22,200–25,000512 / 512
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,400512 / 512
Heating capacity at 17°F / −8.3°C · BTU/h14,100–15,000512 / 512
Heating capacity at 5°F / −15°C · BTU/h10,700–11,500512 / 512
COP at 5°F / −15°C1.9–2.24512 / 512
Equipment / loop typeHP - Split System512 / 512
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)512 / 512
Compressor stagingTwo-stage512 / 512
Connected capabilityNo512 / 512

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
ESH5X30M12A*+ furnace: *80VSL0901716B*AHRI reference: 21565036816.507.80110002.08EPA 3963060 →
ESH5X30M12A*+ furnace: *80VSL0902120B*AHRI reference: 21565038616.508.00112002.06EPA 3963063 →
ESH5X30M12A*+ furnace: *80VSL1102122B*AHRI reference: 21565040416.508.00110002.08EPA 3963080 →
ESH5X30M12A*+ furnace: *80MSU0401712A*AHRI reference: 21565045116.508.00110002.08EPA 3963100 →
ESH5X30M12A*+ furnace: *80MSU0601716A*AHRI reference: 21565047916.507.80111002.08EPA 3963128 →
ESH5X30M12A*+ furnace: *80VTL0451412B*AHRI reference: 21565072816.507.80111002.08EPA 3963186 →
ESH5X30M12A*+ furnace: *80MSU0802120A*AHRI reference: 21565050616.507.80110002.08EPA 3963216 →
ESH5X30M12A*+ furnace: *80CTL0701412B*AHRI reference: 21565057616.508.00110002.06EPA 3963250 →
ESH5X30M12A*+ furnace: *80CTL0701716B*AHRI reference: 21565059716.507.80110002.08EPA 3963267 →
ESH5X30M12A*+ furnace: *97CMN0801714B*AHRI reference: 21565096716.507.80111002.08EPA 3963324 →
ESH5X30M12A*+ furnace: *97CMN1002122B*AHRI reference: 21565100916.507.80110002.08EPA 3963344 →
ESH5X30M12A*+ furnace: *96VSN0802120B*AHRI reference: 21565114716.508.00111002.06EPA 3963627 →
ESH5X30M12A*+ furnace: *96VSN1002120B*AHRI reference: 21565116616.507.80110002.08EPA 3963632 →
ESH5X30M12A*+ furnace: *96VSN1202422B*AHRI reference: 21565118516.507.80110002.08EPA 3963642 →
ESH5X30M12A*+ furnace: *95MSU0601716A*AHRI reference: 21565123616.507.80110002.08EPA 3963665 →
ESH5X30M12A*+ furnace: *95MSU0802120A*AHRI reference: 21565126416.508.00112002.06EPA 3963691 →
ESH5X30M12A*+ furnace: *95MSU1002120A*AHRI reference: 21565129116.508.00111002.08EPA 3963707 →
ESH5X30M12A*+ furnace: *95MSU1002122A*AHRI reference: 21565131516.507.80110002.10EPA 3963724 →
ESH5X30M12A*+ furnace: *96CTN0801714B*AHRI reference: 21565138116.508.00111002.06EPA 3963743 →
ESH5X30M12A*+ furnace: *96CTN1002122B*AHRI reference: 21565142216.507.80110002.08EPA 3963757 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →