N5H5S36*K*AAA*
PERFORMANCE 16 SEER2 HP
29 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for N5H5S36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 29 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 29 / 29 |
| EER2 · BTU/Wh | 11.7–13 | 29 / 29 |
| HSPF2 · BTU/Wh | 7.8–8 | 29 / 29 |
| Cooling capacity · BTU/h | 33,800–36,800 | 29 / 29 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 33,200–36,400 | 29 / 29 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 21,000–22,800 | 29 / 29 |
| Heating capacity at 5°F / −15°C · BTU/h | 16,100–18,100 | 29 / 29 |
| COP at 5°F / −15°C | 2–2.22 | 29 / 29 |
| Equipment / loop type | HP - Split System | 29 / 29 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 29 / 29 |
| Compressor staging | Single stage | 29 / 29 |
| Connected capability | No | 29 / 29 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
FEVA0048**+NAVA54801CKAHRI reference: 217051653 | 16.00 | 8.00 | 17400 | 2.18 | EPA 4001122 → |
FTMA5B48L0C*AHRI reference: 214179959 | 15.50 | 7.80 | 16700 | 2.18 | EPA 3404483 → |
FHMA5*48L*C*AHRI reference: 214180201 | 15.50 | 7.80 | 17400 | 2.18 | EPA 3404817 → |
FEVB0048**+NAVA54801CKAHRI reference: 214277629 | 15.50 | 7.80 | 17400 | 2.22 | EPA 3415707 → |
FMA5X36**AL*AHRI reference: 214424305 | 15.50 | 7.80 | 17000 | 2.00 | EPA 3425192 → |
F5MA5*48L*C*AHRI reference: 216464014 | 15.50 | 7.80 | 17400 | 2.18 | EPA 3846935 → |
EA*5X43M21A*+ furnace: *80MS(N,L)1102120A*AHRI reference: 214139997 | 15.20 | 7.80 | 18000 | 2.20 | EPA 3400461 → |
EA*5X48M21A*+ furnace: *95MSU1002122A*AHRI reference: 214142651 | 15.20 | 7.80 | 17600 | 2.18 | EPA 3400580 → |
EA*5X48M21A*+ furnace: *80CTL1102120B*AHRI reference: 214141854 | 15.20 | 7.80 | 17500 | 2.18 | EPA 3400602 → |
EA*5X48M21A*+ furnace: *80VTL0902120B*AHRI reference: 214141964 | 15.20 | 7.80 | 17500 | 2.18 | EPA 3400629 → |
EA*5X48M21A*+ furnace: *96VTN1002122B*AHRI reference: 214142877 | 15.20 | 7.80 | 17500 | 2.20 | EPA 3400744 → |
EVM5X44M21A*+ furnace: *80ESU0401712A*AHRI reference: 214143069 | 15.20 | 7.80 | 18100 | 2.14 | EPA 3400776 → |
EA*5X43M21A*+ furnace: *92MSN1002120A*AHRI reference: 214140534 | 15.20 | 7.80 | 17900 | 2.20 | EPA 3400808 → |
EA*5X48M21A*+ furnace: *80MS(N,L)0902120A*AHRI reference: 214141361 | 15.20 | 7.80 | 17500 | 2.18 | EPA 3400830 → |
EA*5X48M21A*+ furnace: *80MS(N,L)1102120A*AHRI reference: 214141391 | 15.20 | 7.80 | 17600 | 2.20 | EPA 3400860 → |
EA*5X48M21A*+ furnace: *92MSN1002120A*AHRI reference: 214142280 | 15.20 | 7.80 | 17600 | 2.18 | EPA 3400892 → |
EA*5X48M21A*+ furnace: *80VSL0902120B*AHRI reference: 214141470 | 15.20 | 7.80 | 17500 | 2.18 | EPA 3400935 → |
EA*5X43M21A*+ furnace: *80CSU0601716A*AHRI reference: 214139776 | 15.20 | 7.80 | 17000 | 2.18 | EPA 3401034 → |
EA*5X43M21A*+ furnace: *80CSU1002120A*AHRI reference: 214139803 | 15.20 | 7.80 | 17600 | 2.18 | EPA 3401118 → |
EA*5X37M21A*+ furnace: *80CSU0601716A*AHRI reference: 214138104 | 15.20 | 7.80 | 17100 | 2.16 | EPA 3401180 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →