Kenmore / AIR-SOURCE HEAT PUMP

HH860E2S12

LX SERIES · source records, page 9

236 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range8.1–8.5BTU/Wh
Cooling capacity44,000–54,000BTU/h

Each efficiency range summarizes published EPA records for HH860E2S12. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 236 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18236 / 236
EER2 · BTU/Wh11–12236 / 236
HSPF2 · BTU/Wh8.1–8.5236 / 236
Cooling capacity · BTU/h44,000–54,000236 / 236
Heating capacity at 47°F / 8.3°C · BTU/h45,000–53,500236 / 236
Heating capacity at 17°F / −8.3°C · BTU/h40,000–45,000236 / 236
Heating capacity at 5°F / −15°C · BTU/h33,600–39,000236 / 236
COP at 5°F / −15°C2–2.32236 / 236
Equipment / loop typeHP - Split System236 / 236
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)236 / 236
Compressor stagingTwo-stage236 / 236
Connected capabilityNo236 / 236

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTU60C5XGS2+TXV+ furnace: Z9ES100C20SMPS1*AHRI reference: 21864238017.008.10350002.24EPA 4665325 →
CTF60C5CGS2+ furnace: Z9ES100C20SMPS1*AHRI reference: 21864237617.008.10350002.24EPA 4665329 →
CTU60C5XGS2+TXV+ furnace: Z8ET120C20LMPS1*AHRI reference: 21864234317.008.10344002.24EPA 4665362 →
CTF60C5CGS2+ furnace: Z8ET120C20LMPS1*AHRI reference: 21864234017.008.10344002.24EPA 4665365 →
CTM60D5CGS2+ furnace: Z9ET120D20SMPS1*AHRI reference: 21864230817.008.10344002.24EPA 4665397 →
CTU60C5XGS2+TXV+ furnace: Z8ES120C20LMPS1*AHRI reference: 21864228617.008.10348002.24EPA 4665419 →
CTU60C5XGS2+TXV+ furnace: Z8ES120C20SMPS1*AHRI reference: 21864228317.008.10348002.24EPA 4665422 →
CTF60C5CGS2+ furnace: Z8ES120C20LMPS1*AHRI reference: 21864228017.008.10348002.24EPA 4665425 →
CTF60C5CGS2+ furnace: Z8ES120C20SMPS1*AHRI reference: 21864227717.008.10348002.24EPA 4665428 →
CTM60C5CGS2+ furnace: Z8ES120C20LMPS1*AHRI reference: 21864223817.008.10350002.26EPA 4665467 →
CTM60C5CGS2+ furnace: Z8ES120C20SMPS1*AHRI reference: 21864223517.008.10350002.26EPA 4665470 →
CTM60C5CGS2+ furnace: Z9ET100C20SMPS1AHRI reference: 21864223017.008.10350002.24EPA 4665475 →
CTM60C5CGS2+ furnace: Z9ES100C20SMPS1*AHRI reference: 21864222617.008.10350002.24EPA 4665479 →
CTU60C5XGS2+TXV+ furnace: Z8ET100C20LMPS1*AHRI reference: 21864219317.008.10348002.26EPA 4665512 →
CTF60C5CGS2+ furnace: Z8ET100C20LMPS1*AHRI reference: 21864219017.008.10348002.26EPA 4665515 →
CTU60C5XGS2+TXV+ furnace: Z9ES080C20SMPS1*AHRI reference: 21864217517.008.10342002.20EPA 4665530 →
CTF60C5CGS2+ furnace: Z9ES080C20SMPS1*AHRI reference: 21864217217.008.10342002.20EPA 4665533 →
CTF60D5CGS2+ furnace: Z9ET120D20SMPS1*AHRI reference: 21864214717.008.10344002.24EPA 4665558 →
CTM60C5CGS2+ furnace: Z9ES100C16SMPS1*AHRI reference: 21864213317.008.10346002.22EPA 4665572 →
CTM60C5CGS1+ furnace: Z8ET120C20LMPS1*AHRI reference: 21869818117.008.10344002.24EPA 4684299 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →