Kenmore / AIR-SOURCE HEAT PUMP

HH860E2S12

LX SERIES · source records, page 11

236 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range8.1–8.5BTU/Wh
Cooling capacity44,000–54,000BTU/h

Each efficiency range summarizes published EPA records for HH860E2S12. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 236 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18236 / 236
EER2 · BTU/Wh11–12236 / 236
HSPF2 · BTU/Wh8.1–8.5236 / 236
Cooling capacity · BTU/h44,000–54,000236 / 236
Heating capacity at 47°F / 8.3°C · BTU/h45,000–53,500236 / 236
Heating capacity at 17°F / −8.3°C · BTU/h40,000–45,000236 / 236
Heating capacity at 5°F / −15°C · BTU/h33,600–39,000236 / 236
COP at 5°F / −15°C2–2.32236 / 236
Equipment / loop typeHP - Split System236 / 236
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)236 / 236
Compressor stagingTwo-stage236 / 236
Connected capabilityNo236 / 236

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTF60C5CGS1+ furnace: Z9ES080C20SMPS1*AHRI reference: 21869812817.008.10342002.20EPA 4684352
CTM60D5CGS1+ furnace: Z9ET120D20SMPS1*AHRI reference: 21869812317.008.10344002.24EPA 4684357
CTU60C5XGS1+TXV+ furnace: Z8ES120C20LMPS1*AHRI reference: 21869810917.008.10348002.24EPA 4684371
CTU60C5XGS1+TXV+ furnace: Z8ES120C20SMPS1*AHRI reference: 21869810817.008.10348002.24EPA 4684372
CTF60C5CGS1+ furnace: Z8ES120C20LMPS1*AHRI reference: 21869810717.008.10348002.24EPA 4684373
CTF60C5CGS1+ furnace: Z8ES120C20SMPS1*AHRI reference: 21869810617.008.10348002.24EPA 4684374
CTM60C5CGS1+ furnace: Z8ES120C20LMPS1*AHRI reference: 21869809517.008.10350002.26EPA 4684385
CTM60C5CGS1+ furnace: Z8ES120C20SMPS1*AHRI reference: 21869809417.008.10350002.26EPA 4684386
CTF60D5CGS1+ furnace: Z9ET120D20SMPS1*AHRI reference: 21869809317.008.10344002.24EPA 4684387
CTM60C5CGS1+ furnace: Z9ES100C16SMPS1*AHRI reference: 21869808917.008.10346002.22EPA 4684391
CTM60D5CJS1+ furnace: Z9ET120D20SMPS1*AHRI reference: 21869808717.008.10390002.24EPA 4684393
CTM60D5CJS1+ furnace: Z8ES130D20LMPS1*AHRI reference: 21869808617.008.10390002.28EPA 4684394
CTM60D5CJS1+ furnace: Z8ES130D20SMPS1*AHRI reference: 21869808517.008.10390002.28EPA 4684395
CTF60D5CJS1+ furnace: Z9ET120D20SMPS1*AHRI reference: 21869808417.008.10390002.26EPA 4684396
CTM60D5CJS2+ furnace: Z9ES120D20SMPS1*AHRI reference: 21864249816.508.10390002.24EPA 4665209
CTF60D5CJS2+ furnace: Z9ES120D20SMPS1*AHRI reference: 21864249516.508.10390002.24EPA 4665212
CTM60D5CGS2+ furnace: Z9ES120D20SMPS1*AHRI reference: 21864240016.508.10352002.26EPA 4665305
CTF60D5CGS2+ furnace: Z9ES120D20SMPS1*AHRI reference: 21864220716.508.10342002.24EPA 4665498
CTU60C5XGS2+TXV+ furnace: Z9ES100C16SMPS1*AHRI reference: 21864214416.508.10346002.22EPA 4665561
CTF60C5CGS2+ furnace: Z9ES100C16SMPS1*AHRI reference: 21864214116.508.10346002.22EPA 4665564

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →