HH860E2S11*
LX SERIES · source records, page 9
206 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for HH860E2S11*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 206 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 206 / 206 |
| EER2 · BTU/Wh | 10–12 | 206 / 206 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 206 / 206 |
| Cooling capacity · BTU/h | 43,500–54,000 | 206 / 206 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 43,500–55,500 | 206 / 206 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 31,800–38,000 | 206 / 206 |
| Heating capacity at 5°F / −15°C · BTU/h | 32,000–40,000 | 206 / 206 |
| COP at 5°F / −15°C | 2 | 206 / 206 |
| Equipment / loop type | HP - Split System | 206 / 206 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 206 / 206 |
| Compressor staging | Continuously variable | 206 / 206 |
| Connected capability | No | 206 / 206 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTF60C5CGS2+ furnace: Z8ES080C20LMPS1*AHRI reference: 218600387 | 18.00 | 9.00 | 33400 | 2.00 | EPA 4651493 → |
CTU60C5XGS2+TXV+ furnace: Z9ES100C16SMPS1*AHRI reference: 218600386 | 18.00 | 9.00 | 34200 | 2.00 | EPA 4651494 → |
CTU60C5XGS2+TXV+ furnace: Z8ES080C20LMPS1*AHRI reference: 218600385 | 18.00 | 9.00 | 33400 | 2.00 | EPA 4651495 → |
CTF60C5CGS2+ furnace: Z8ES080C20SMPS1*AHRI reference: 218600384 | 18.00 | 9.00 | 33400 | 2.00 | EPA 4651496 → |
CTU60C5XGS2+TXV+ furnace: Z8ES080C16LMPS1*AHRI reference: 218600383 | 18.00 | 9.00 | 33400 | 2.00 | EPA 4651497 → |
CTU60C5XGS2+TXV+ furnace: Z8ES080C16SMPS1*AHRI reference: 218600382 | 18.00 | 9.00 | 33400 | 2.00 | EPA 4651498 → |
CTF60C5CGS2+ furnace: Z8ES080C16LMPS1*AHRI reference: 218600381 | 18.00 | 9.00 | 33400 | 2.00 | EPA 4651499 → |
CTF60C5CGS2+ furnace: Z8ES080C16SMPS1*AHRI reference: 218600380 | 18.00 | 9.00 | 33400 | 2.00 | EPA 4651500 → |
CTF60C5CGS2+ furnace: Z9ET080C16SMPS1AHRI reference: 218600379 | 18.00 | 9.00 | 32800 | 2.00 | EPA 4651501 → |
CTU60C5XGS2+TXV+ furnace: Z9ET080C16SMPS1AHRI reference: 218600378 | 18.00 | 9.00 | 32800 | 2.00 | EPA 4651502 → |
CTU60C5XGS2+TXV+ furnace: Z9ET100C20SMPS1AHRI reference: 218600377 | 18.00 | 9.00 | 33000 | 2.00 | EPA 4651503 → |
CTF60C5CGS2+ furnace: Z9ET100C20SMPS1AHRI reference: 218600376 | 18.00 | 9.00 | 33000 | 2.00 | EPA 4651504 → |
CTF60D5CJS2+ furnace: Z9ES120D20SMPS1*AHRI reference: 218599877 | 18.00 | 9.00 | 39500 | 2.00 | EPA 4651839 → |
CTM60D5CGS2+JME18D2SN2AHRI reference: 218637354 | 18.00 | 9.50 | 33800 | 2.00 | EPA 4664135 → |
CTM60C5CGS1+ furnace: Z8ET100C20LMPS1Cold climate designationAHRI reference: 217455894 | 17.00 | 9.50 | 33400 | 2.00 | EPA 4047565 → |
CTF60C5CGS1+ furnace: Z8ET100C16LMPS1Cold climate designationAHRI reference: 217455898 | 17.00 | 9.00 | 32600 | 2.00 | EPA 4047569 → |
CTU60C5XGS1+TXV+ furnace: Z8ET100C16LMPS1Cold climate designationAHRI reference: 217455899 | 17.00 | 9.00 | 32600 | 2.00 | EPA 4047570 → |
CTM60C5CGS1+ furnace: Z8ET100C16LMPS1Cold climate designationAHRI reference: 217455880 | 17.00 | 9.00 | 32600 | 2.00 | EPA 4047580 → |
CTF60C5CGS1+ furnace: Z8ET100C20LMPS1Cold climate designationAHRI reference: 217455883 | 17.00 | 9.00 | 33400 | 2.00 | EPA 4047582 → |
CTU60C5XGS1+TXV+ furnace: Z8ET100C20LMPS1Cold climate designationAHRI reference: 217455884 | 17.00 | 9.00 | 33400 | 2.00 | EPA 4048413 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.