SEER2 range15.2–19BTU/Wh
HSPF2 range8.1–9.5BTU/Wh
Cooling capacity43,500–54,000BTU/h

Each efficiency range summarizes published EPA records for HH860E2S11*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 206 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–19206 / 206
EER2 · BTU/Wh10–12206 / 206
HSPF2 · BTU/Wh8.1–9.5206 / 206
Cooling capacity · BTU/h43,500–54,000206 / 206
Heating capacity at 47°F / 8.3°C · BTU/h43,500–55,500206 / 206
Heating capacity at 17°F / −8.3°C · BTU/h31,800–38,000206 / 206
Heating capacity at 5°F / −15°C · BTU/h32,000–40,000206 / 206
COP at 5°F / −15°C2206 / 206
Equipment / loop typeHP - Split System206 / 206
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)206 / 206
Compressor stagingContinuously variable206 / 206
Connected capabilityNo206 / 206

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTF60C5CHS1+ furnace: Z8VT100C20SMPC1Cold climate designationAHRI reference: 21744419519.009.00385002.00EPA 4042901
CTF60C5CHS1+ furnace: Z8VT120C20SMPC1Cold climate designationAHRI reference: 21744419619.009.00385002.00EPA 4042902
CTM60C5CHS1+ furnace: Z8VT100C20SMPC1Cold climate designationAHRI reference: 21744419719.009.00385002.00EPA 4042903
CTM60C5CHS1+ furnace: Z8VT120C20SMPC1Cold climate designationAHRI reference: 21744419819.009.00385002.00EPA 4042904
CTM60C5CHS1+ furnace: Z8ET100C20LMPS1Cold climate designationAHRI reference: 21745589519.009.00380002.00EPA 4047566
CTF60C5CGS1+ furnace: Z8ET120C20LMPS1Cold climate designationAHRI reference: 21745588919.009.00320002.00EPA 4047575
CTU60C5XGS1+TXV+ furnace: Z8ET120C20LMPS1Cold climate designationAHRI reference: 21745589019.009.00320002.00EPA 4047576
CTF60C5CHS1+ furnace: Z8ET120C20LMPS1Cold climate designationAHRI reference: 21745589119.009.00385002.00EPA 4047577
CTM60C5CHS1+ furnace: Z8ET120C20LMPS1Cold climate designationAHRI reference: 21745588119.009.00385002.00EPA 4047581
CTF60C5CHS1+ furnace: Z8ET100C20LMPS1Cold climate designationAHRI reference: 21745590219.009.00380002.00EPA 4048412
JSE48C5CG2SS1Cold climate designationAHRI reference: 21761207419.009.00330002.00EPA 4497872
JHE48C5CG2SS1Cold climate designationAHRI reference: 21694077319.009.00330002.00EPA 4498154
JHE60D5CJ2SS1Cold climate designationAHRI reference: 21694107219.008.50390002.00EPA 4498156
JHE60C5CH2SS1Cold climate designationAHRI reference: 21694130519.009.00385002.00EPA 4498157
JHE60D5CH2SS1Cold climate designationAHRI reference: 21694176619.008.50385002.00EPA 4498160
JSE60D5CJ2SS1Cold climate designationAHRI reference: 21694180819.008.50390002.00EPA 4498162
JHE48D5CG2SS1Cold climate designationAHRI reference: 21694216619.009.00334002.00EPA 4498165
JHE48C5CG2SS2Cold climate designationAHRI reference: 21845733419.009.00330002.00EPA 4639405
JHE60C5CH2SS2Cold climate designationAHRI reference: 21845732819.009.00385002.00EPA 4639406
JHE60D5CH2SS2Cold climate designationAHRI reference: 21845732719.008.50385002.00EPA 4639407

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.