Kenmore / AIR-SOURCE HEAT PUMP

HH836E2S11*

LX SERIES · source records, page 14

381 published source records · source checked Sep 21, 2026

SEER2 range15.2–19BTU/Wh
HSPF2 range8.1–9.5BTU/Wh
Cooling capacity31,600–35,000BTU/h

Each efficiency range summarizes published EPA records for HH836E2S11*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 381 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–19381 / 381
EER2 · BTU/Wh10–12381 / 381
HSPF2 · BTU/Wh8.1–9.5381 / 381
Cooling capacity · BTU/h31,600–35,000381 / 381
Heating capacity at 47°F / 8.3°C · BTU/h30,000–33,000381 / 381
Heating capacity at 17°F / −8.3°C · BTU/h25,400–29,600381 / 381
Heating capacity at 5°F / −15°C · BTU/h22,200–27,200381 / 381
COP at 5°F / −15°C2–2.1381 / 381
Equipment / loop typeHP - Split System381 / 381
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)381 / 381
Compressor stagingContinuously variable381 / 381
Connected capabilityNo381 / 381

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTU48C5XFS2+TXV+ furnace: Z9ES080C20SMPS1*AHRI reference: 21860012218.009.00256002.00EPA 4651596
CTF48C5CFS2+ furnace: Z9ES080C20SMPS1*AHRI reference: 21860012118.009.00256002.00EPA 4651597
CTF48C5AFS2+ furnace: Z9ES080C20SMPS1*AHRI reference: 21860012018.009.00256002.00EPA 4651598
CTF36C5CDS2+ furnace: Z9ET080C16SMPS1AHRI reference: 21860010718.008.50238002.00EPA 4651611
CTF36C5ADS2+ furnace: Z9ET080C16SMPS1AHRI reference: 21860010618.008.50238002.00EPA 4651612
CTF36C5CDS2+ furnace: Z9ET100C16SMPS1AHRI reference: 21860010318.008.50230002.00EPA 4651615
CTF36C5ADS2+ furnace: Z9ET100C16SMPS1AHRI reference: 21860010218.008.50230002.00EPA 4651616
CTF36C5CDS2+ furnace: Z8ES120C16LMPS1*AHRI reference: 21860010118.008.50258002.00EPA 4651617
CTF36C5CDS2+ furnace: Z8ES120C16SMPS1*AHRI reference: 21860010018.008.50258002.00EPA 4651618
CTF36C5ADS2+ furnace: Z8ES120C16LMPS1*AHRI reference: 21860009918.008.50258002.00EPA 4651619
CTF36C5ADS2+ furnace: Z8ES120C16SMPS1*AHRI reference: 21860009818.008.50258002.00EPA 4651620
CTF36C5ADS2+ furnace: Z9ES100C20SMPS1*AHRI reference: 21860009518.008.50272002.00EPA 4651623
CTF36C5CDS2+ furnace: Z9ES080C16SMPS1*AHRI reference: 21860009418.008.50250002.00EPA 4651624
CTF36C5CDS2+ furnace: Z9ES100C20SMPS1*AHRI reference: 21860009318.008.50272002.00EPA 4651625
CTF36C5ADS2+ furnace: Z9ES080C16SMPS1*AHRI reference: 21860009218.008.50250002.00EPA 4651626
CTF36C5CDS2+ furnace: Z8ES120C20SMPS1*AHRI reference: 21860009118.008.50262002.00EPA 4651627
CTF36C5ADS2+ furnace: Z8ES120C20LMPS1*AHRI reference: 21860009018.008.50262002.00EPA 4651628
CTF36C5ADS2+ furnace: Z8ES120C20SMPS1*AHRI reference: 21860008918.008.50262002.00EPA 4651629
CTF36C5CDS2+ furnace: Z8ES120C20LMPS1*AHRI reference: 21860008818.008.50262002.00EPA 4651630
CTF36C5CDS2+ furnace: Z8ES080C16LMPS1*AHRI reference: 21860008718.008.50254002.00EPA 4651631

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →