Kenmore / AIR-SOURCE HEAT PUMP

HH836E2S11*

LX SERIES · source records, page 14

381 published source records · source checked Sep 21, 2026

SEER2 range15.2–19BTU/Wh
HSPF2 range8.1–9.5BTU/Wh
Cooling capacity31,600–35,000BTU/h

Each efficiency range summarizes published EPA records for HH836E2S11*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 381 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–19381 / 381
EER2 · BTU/Wh10–12381 / 381
HSPF2 · BTU/Wh8.1–9.5381 / 381
Cooling capacity · BTU/h31,600–35,000381 / 381
Heating capacity at 47°F / 8.3°C · BTU/h30,000–33,000381 / 381
Heating capacity at 17°F / −8.3°C · BTU/h25,400–29,600381 / 381
Heating capacity at 5°F / −15°C · BTU/h22,200–27,200381 / 381
COP at 5°F / −15°C2–2.1381 / 381
Equipment / loop typeHP - Split System381 / 381
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)381 / 381
Compressor stagingContinuously variable381 / 381
Connected capabilityNo381 / 381

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTU48C5XFS2+TXV+ furnace: Z9ES080C20SMPS1*AHRI reference: 21860012218.009.00256002.00EPA 4651596 →
CTF48C5CFS2+ furnace: Z9ES080C20SMPS1*AHRI reference: 21860012118.009.00256002.00EPA 4651597 →
CTF48C5AFS2+ furnace: Z9ES080C20SMPS1*AHRI reference: 21860012018.009.00256002.00EPA 4651598 →
CTF36C5CDS2+ furnace: Z9ET080C16SMPS1AHRI reference: 21860010718.008.50238002.00EPA 4651611 →
CTF36C5ADS2+ furnace: Z9ET080C16SMPS1AHRI reference: 21860010618.008.50238002.00EPA 4651612 →
CTF36C5CDS2+ furnace: Z9ET100C16SMPS1AHRI reference: 21860010318.008.50230002.00EPA 4651615 →
CTF36C5ADS2+ furnace: Z9ET100C16SMPS1AHRI reference: 21860010218.008.50230002.00EPA 4651616 →
CTF36C5CDS2+ furnace: Z8ES120C16LMPS1*AHRI reference: 21860010118.008.50258002.00EPA 4651617 →
CTF36C5CDS2+ furnace: Z8ES120C16SMPS1*AHRI reference: 21860010018.008.50258002.00EPA 4651618 →
CTF36C5ADS2+ furnace: Z8ES120C16LMPS1*AHRI reference: 21860009918.008.50258002.00EPA 4651619 →
CTF36C5ADS2+ furnace: Z8ES120C16SMPS1*AHRI reference: 21860009818.008.50258002.00EPA 4651620 →
CTF36C5ADS2+ furnace: Z9ES100C20SMPS1*AHRI reference: 21860009518.008.50272002.00EPA 4651623 →
CTF36C5CDS2+ furnace: Z9ES080C16SMPS1*AHRI reference: 21860009418.008.50250002.00EPA 4651624 →
CTF36C5CDS2+ furnace: Z9ES100C20SMPS1*AHRI reference: 21860009318.008.50272002.00EPA 4651625 →
CTF36C5ADS2+ furnace: Z9ES080C16SMPS1*AHRI reference: 21860009218.008.50250002.00EPA 4651626 →
CTF36C5CDS2+ furnace: Z8ES120C20SMPS1*AHRI reference: 21860009118.008.50262002.00EPA 4651627 →
CTF36C5ADS2+ furnace: Z8ES120C20LMPS1*AHRI reference: 21860009018.008.50262002.00EPA 4651628 →
CTF36C5ADS2+ furnace: Z8ES120C20SMPS1*AHRI reference: 21860008918.008.50262002.00EPA 4651629 →
CTF36C5CDS2+ furnace: Z8ES120C20LMPS1*AHRI reference: 21860008818.008.50262002.00EPA 4651630 →
CTF36C5CDS2+ furnace: Z8ES080C16LMPS1*AHRI reference: 21860008718.008.50254002.00EPA 4651631 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →