HH836E2S11*
LX SERIES · source records, page 11
381 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for HH836E2S11*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 381 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 381 / 381 |
| EER2 · BTU/Wh | 10–12 | 381 / 381 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 381 / 381 |
| Cooling capacity · BTU/h | 31,600–35,000 | 381 / 381 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 30,000–33,000 | 381 / 381 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 25,400–29,600 | 381 / 381 |
| Heating capacity at 5°F / −15°C · BTU/h | 22,200–27,200 | 381 / 381 |
| COP at 5°F / −15°C | 2–2.1 | 381 / 381 |
| Equipment / loop type | HP - Split System | 381 / 381 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 381 / 381 |
| Compressor staging | Continuously variable | 381 / 381 |
| Connected capability | No | 381 / 381 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTM36C5ADS2+ furnace: Z8ET080C16LMPS1*AHRI reference: 218599944 | 19.00 | 8.50 | 23400 | 2.00 | EPA 4651774 → |
CTU36B5XDS2+TXV+ furnace: Z8ET080B12LMPS1*AHRI reference: 218599941 | 19.00 | 9.00 | 22800 | 2.00 | EPA 4651777 → |
CTF36B5CDS2+ furnace: Z8ET080B12LMPS1*AHRI reference: 218599940 | 19.00 | 9.00 | 22800 | 2.00 | EPA 4651778 → |
CTF36B5ADS2+ furnace: Z8ET080B12LMPS1*AHRI reference: 218599939 | 19.00 | 9.00 | 22800 | 2.00 | EPA 4651779 → |
CTU36B5XDS2+JMC12B2SN1+TXVAHRI reference: 218599932 | 19.00 | 9.00 | 25600 | 2.00 | EPA 4651786 → |
CTF36B5CDS2+JMC12B2SN1AHRI reference: 218599931 | 19.00 | 9.00 | 25600 | 2.00 | EPA 4651787 → |
CTF36B5ADS2+JMC12B2SN1AHRI reference: 218599930 | 19.00 | 9.00 | 25600 | 2.00 | EPA 4651788 → |
CTF36C5CDS2+JME16C2SN2AHRI reference: 218637297 | 19.00 | 9.00 | 25600 | 2.00 | EPA 4664153 → |
CTF36C5ADS2+JME16C2SN2AHRI reference: 218637293 | 19.00 | 9.00 | 25600 | 2.00 | EPA 4664154 → |
CTM36C5CDS2+JME16C2SN2AHRI reference: 218637289 | 19.00 | 9.00 | 25600 | 2.00 | EPA 4664155 → |
CTM36C5ADS2+JME16C2SN2AHRI reference: 218637286 | 19.00 | 9.00 | 25600 | 2.00 | EPA 4664156 → |
CTM48C5CFS2+JME12C2SN2AHRI reference: 218637282 | 19.00 | 9.00 | 25200 | 2.00 | EPA 4664157 → |
CTM48C5AFS2+JME12C2SN2AHRI reference: 218637278 | 19.00 | 9.00 | 25200 | 2.00 | EPA 4664158 → |
CTF36C5CDS2+JME12C2SN2AHRI reference: 218637275 | 19.00 | 9.00 | 25600 | 2.00 | EPA 4664159 → |
CTF36C5ADS2+JME12C2SN2AHRI reference: 218637271 | 19.00 | 9.00 | 25600 | 2.00 | EPA 4664160 → |
CTM48C5CFS2+JME16C2SN2AHRI reference: 218637268 | 19.00 | 9.00 | 25200 | 2.00 | EPA 4664161 → |
CTM48C5AFS2+JME16C2SN2AHRI reference: 218637264 | 19.00 | 9.00 | 25200 | 2.00 | EPA 4664162 → |
CTU36B5XDS2+JME12B2SN2+TXVAHRI reference: 218637260 | 19.00 | 9.00 | 25800 | 2.00 | EPA 4664163 → |
CTF36B5CDS2+JME12B2SN2AHRI reference: 218637256 | 19.00 | 9.00 | 25800 | 2.00 | EPA 4664164 → |
CTF36B5ADS2+JME12B2SN2AHRI reference: 218637253 | 19.00 | 9.00 | 25800 | 2.00 | EPA 4664165 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →