Kenmore / AIR-SOURCE HEAT PUMP

HH824E2S12

LX SERIES

143 published source records · source checked Sep 21, 2026

SEER2 range16–18BTU/Wh
HSPF2 range8.1–8.5BTU/Wh
Cooling capacity22,800–24,000BTU/h

Each efficiency range summarizes published EPA records for HH824E2S12. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 143 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh16–18143 / 143
EER2 · BTU/Wh11–12143 / 143
HSPF2 · BTU/Wh8.1–8.5143 / 143
Cooling capacity · BTU/h22,800–24,000143 / 143
Heating capacity at 47°F / 8.3°C · BTU/h22,800–24,000143 / 143
Heating capacity at 17°F / −8.3°C · BTU/h20,600–22,400143 / 143
Heating capacity at 5°F / −15°C · BTU/h17,200–18,500143 / 143
COP at 5°F / −15°C2.22–2.46143 / 143
Equipment / loop typeHP - Split System143 / 143
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)143 / 143
Compressor stagingTwo-stage143 / 143
Connected capabilityNo143 / 143

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
JHC24B5AC2SS1Cold climate designationAHRI reference: 21859822418.008.50180002.30EPA 4651089 →
JHE30B5AD2SS2Cold climate designationAHRI reference: 21864295717.508.50178002.40EPA 4665047 →
JHC36B5AD2SS1Cold climate designationAHRI reference: 21864293617.508.50180002.42EPA 4665055 →
CTM36B5ADS2+ furnace: Z8ET080B12LMPS1*Cold climate designationAHRI reference: 21864291917.508.50182002.42EPA 4665061 →
CTU30B5XCS2+TXV+ furnace: Z8VT080B12SMPC1Cold climate designationAHRI reference: 21864276317.508.50181002.34EPA 4665067 →
CTF30B5ACS2+ furnace: Z8VT080B12SMPC1Cold climate designationAHRI reference: 21864276117.508.50181002.34EPA 4665068 →
JHE24B5AC2SS2Cold climate designationAHRI reference: 21864275217.508.50179002.32EPA 4665071 →
CTU36B5XDS2+TXV+ furnace: Z8VT080B12SMPC1Cold climate designationAHRI reference: 21864291017.508.50178002.40EPA 4667004 →
CTF36B5ADS2+ furnace: Z8VT080B12SMPC1Cold climate designationAHRI reference: 21864290717.508.50178002.40EPA 4667005 →
CTM36B5ADS2+ furnace: Z8VT080B12SMPC1Cold climate designationAHRI reference: 21864290517.508.50178002.40EPA 4667006 →
CTM36B5ADS2+JMC12B2SN1Cold climate designationAHRI reference: 21864290217.508.50181002.44EPA 4667007 →
CTU36B5XDS2+JMC12B2SN1+TXVCold climate designationAHRI reference: 21864289017.508.50181002.46EPA 4667012 →
CTF36B5ADS2+JMC12B2SN1Cold climate designationAHRI reference: 21864288617.508.50181002.46EPA 4667013 →
CTU36B5XDS2+JME12B2SN2+TXVCold climate designationAHRI reference: 21864288317.508.50178002.40EPA 4667014 →
CTF36B5ADS2+JME12B2SN2Cold climate designationAHRI reference: 21864288117.508.50178002.40EPA 4667015 →
CTU36B5XDS2+TXV+ furnace: Z8ET080B12LMPS1*Cold climate designationAHRI reference: 21864286917.508.50182002.42EPA 4667019 →
CTF36B5ADS2+ furnace: Z8ET080B12LMPS1*Cold climate designationAHRI reference: 21864286617.508.50182002.42EPA 4667020 →
CTM30B5ACS2+ furnace: Z8VT080B12SMPC1Cold climate designationAHRI reference: 21864285017.508.50182002.32EPA 4667025 →
CTU30B5XCS2+TXV+ furnace: Z8ET080B12LMPS1*Cold climate designationAHRI reference: 21864282217.508.50181002.32EPA 4667034 →
CTF30B5ACS2+ furnace: Z8ET080B12LMPS1*Cold climate designationAHRI reference: 21864281917.508.50181002.32EPA 4667035 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.