HH824E2S11*
LX SERIES · source records, page 5
103 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for HH824E2S11*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 103 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 103 / 103 |
| EER2 · BTU/Wh | 11–12 | 103 / 103 |
| HSPF2 · BTU/Wh | 8.5–9.5 | 103 / 103 |
| Cooling capacity · BTU/h | 23,000 | 103 / 103 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 23,000 | 103 / 103 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 17,200–18,800 | 103 / 103 |
| Heating capacity at 5°F / −15°C · BTU/h | 17,200–19,400 | 103 / 103 |
| COP at 5°F / −15°C | 2 | 103 / 103 |
| Equipment / loop type | HP - Split System | 103 / 103 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 103 / 103 |
| Compressor staging | Continuously variable | 103 / 103 |
| Connected capability | No | 103 / 103 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTF30A5ADS2+ furnace: Z8ES040A12SMPS1*AHRI reference: 218599780 | 18.00 | 9.50 | 18900 | 2.00 | EPA 4651935 → |
CTF30A5ADS2+ furnace: Z9ES026A08SMPS1*AHRI reference: 218599779 | 18.00 | 9.00 | 18100 | 2.00 | EPA 4651936 → |
CTM30B5ACS2+JME08B2SN2AHRI reference: 218637204 | 18.00 | 9.50 | 18100 | 2.00 | EPA 4664181 → |
CTU30B5XCS2+JME12B2SN2+TXVAHRI reference: 218637201 | 18.00 | 9.50 | 18500 | 2.00 | EPA 4664182 → |
CTF30B5ACS2+JME12B2SN2AHRI reference: 218637197 | 18.00 | 9.50 | 18500 | 2.00 | EPA 4664183 → |
CTM36B5ADS2+JME12B2SN2AHRI reference: 218637195 | 18.00 | 9.50 | 18000 | 2.00 | EPA 4664184 → |
CTU30B5XCS2+JME08B2SN2+TXVAHRI reference: 218637191 | 18.00 | 9.50 | 18200 | 2.00 | EPA 4664185 → |
CTF30B5ACS2+JME08B2SN2AHRI reference: 218637188 | 18.00 | 9.50 | 18200 | 2.00 | EPA 4664186 → |
CTM36B5ADS2+JME08B2SN2AHRI reference: 218637185 | 18.00 | 9.00 | 17800 | 2.00 | EPA 4664187 → |
CTM30B5ACS2+JME12B2SN2AHRI reference: 218637181 | 18.00 | 9.50 | 18400 | 2.00 | EPA 4664188 → |
CTM36B5ADS2+ furnace: Z9ES060B12SMPS1*AHRI reference: 218599853 | 17.00 | 9.50 | 18600 | 2.00 | EPA 4651862 → |
CTM30B5ACS2+ furnace: Z9ES060B12SMPS1*AHRI reference: 218599839 | 17.00 | 9.50 | 19200 | 2.00 | EPA 4651876 → |
CTU36B5XDS2+TXV+ furnace: Z9ES060B12SMPS1*AHRI reference: 218599823 | 17.00 | 9.50 | 18700 | 2.00 | EPA 4651892 → |
CTF36B5ADS2+ furnace: Z9ES060B12SMPS1*AHRI reference: 218599822 | 17.00 | 9.50 | 18700 | 2.00 | EPA 4651893 → |
CTU30B5XCS2+TXV+ furnace: Z9ES080B12SMPS1*AHRI reference: 218599793 | 17.00 | 9.50 | 18400 | 2.00 | EPA 4651922 → |
CTF30B5ACS2+ furnace: Z9ES080B12SMPS1*AHRI reference: 218599792 | 17.00 | 9.50 | 18400 | 2.00 | EPA 4651923 → |
CTU30B5XCS2+TXV+ furnace: Z9ES060B12SMPS1*AHRI reference: 218599791 | 17.00 | 9.50 | 19100 | 2.00 | EPA 4651924 → |
CTF30B5ACS2+ furnace: Z9ES060B12SMPS1*AHRI reference: 218599790 | 17.00 | 9.50 | 19100 | 2.00 | EPA 4651925 → |
CTF30A5ADS2+ furnace: Z9ET040A10SMPS1*AHRI reference: 218599778 | 17.00 | 9.00 | 17200 | 2.00 | EPA 4651937 → |
CTU30B5XCS1+TXVCold climate designationAHRI reference: 217465278 | 15.20 | 8.50 | 17400 | 2.00 | EPA 4468441 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →