Kenmore / AIR-SOURCE HEAT PUMP

(C,H,T)5H8T60*K*AAA*

Mainline 18 SEER2 HP · source records, page 4

84 published source records · source checked Sep 21, 2026

SEER2 range15.5–17.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity54,000–57,500BTU/h

Each efficiency range summarizes published EPA records for (C,H,T)5H8T60*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 84 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.5–17.584 / 84
EER2 · BTU/Wh11.7–1384 / 84
HSPF2 · BTU/Wh7.8–8.584 / 84
Cooling capacity · BTU/h54,000–57,50084 / 84
Heating capacity at 47°F / 8.3°C · BTU/h56,500–60,00084 / 84
Heating capacity at 17°F / −8.3°C · BTU/h36,200–38,50084 / 84
Heating capacity at 5°F / −15°C · BTU/h29,600–31,80084 / 84
COP at 5°F / −15°C2.18–2.3684 / 84
Equipment / loop typeHP - Split System84 / 84
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)84 / 84
Compressor stagingTwo-stage84 / 84
Connected capabilityNo84 / 84

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X60M24A*+ furnace: *80MSU1002120A*AHRI reference: 21634806816.007.80296002.24EPA 3806856
EA*5X61M24A*+ furnace: *80VTL0902120B*AHRI reference: 21634874816.008.00300002.26EPA 3806912
EVD5X61M21A*+ furnace: *80VSL0902120B*AHRI reference: 21634747616.008.10310002.24EPA 3807154
EVD5X61M21A*+ furnace: *80MSU0802120A*AHRI reference: 21634749216.008.10306002.26EPA 3807162
EVD5X61M21A*+ furnace: *80MSU1002120A*AHRI reference: 21634750016.008.10310002.22EPA 3807170
EA*5X61M21A*+ furnace: *95MSU1002120A*AHRI reference: 21634853216.007.80302002.22EPA 3807272
EA*5X60M24A*+ furnace: *95MSU1002122A*AHRI reference: 21634821216.007.80296002.22EPA 3807283
EA*5X61M21A*+ furnace: *96VTN0802120B*AHRI reference: 21634856416.007.80304002.20EPA 3807306
EA*5X61M21A*+ furnace: *96VTN1002120B*AHRI reference: 21634857216.007.80302002.22EPA 3807314
EA*5X60M24A*+ furnace: *96VTN0802120B*AHRI reference: 21634824416.007.80300002.20EPA 3807345
EA*5X60M24A*+ furnace: *96VTN1002120B*AHRI reference: 21634825216.007.80298002.22EPA 3807353
EA*5X60M24A*+ furnace: *96VTN1002122B*AHRI reference: 21634826016.007.80296002.22EPA 3807361
EA*5X60M24A*+ furnace: *96VTN1202422B*AHRI reference: 21634826816.007.80300002.22EPA 3807369
EA*5X60M24A*+ furnace: *96VSN1002120B*AHRI reference: 21634818015.507.80298002.20EPA 3802073
EVM5X61M24A*+ furnace: *80VSL0902120B*AHRI reference: 21634661215.508.50318002.32EPA 3802164
EVD5X60M21A*+ furnace: *80VSL0902120B*AHRI reference: 21634694015.508.10304002.22EPA 3805330
EVD5X60M21A*+ furnace: *80MSU0601716A*AHRI reference: 21634695615.508.10306002.24EPA 3805346
EVD5X60M21A*+ furnace: *80MSU1002120A*AHRI reference: 21634697215.508.10304002.24EPA 3805362
EVM5X60M21A*+ furnace: *95MSU1002120A*AHRI reference: 21634622815.508.10302002.24EPA 3805518
EVD5X61M24A*+ furnace: *80VSL1352422B*AHRI reference: 21634774815.508.50318002.32EPA 3805646