Kenmore / AIR-SOURCE HEAT PUMP

(C,H,T)5H8T48*K*AAA*

Mainline 18 SEER2 HP · source records, page 7

413 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity45,500–50,500BTU/h

Each efficiency range summarizes published EPA records for (C,H,T)5H8T48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 413 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18413 / 413
EER2 · BTU/Wh11.7–13.5413 / 413
HSPF2 · BTU/Wh7.8–8.5413 / 413
Cooling capacity · BTU/h45,500–50,500413 / 413
Heating capacity at 47°F / 8.3°C · BTU/h48,500–52,500413 / 413
Heating capacity at 17°F / −8.3°C · BTU/h29,400–32,400413 / 413
Heating capacity at 5°F / −15°C · BTU/h23,200–26,600413 / 413
COP at 5°F / −15°C2.1–2.34413 / 413
Equipment / loop typeHP - Split System413 / 413
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)413 / 413
Compressor stagingTwo-stage413 / 413
Connected capabilityNo413 / 413

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EVM5X60M21A*+ furnace: *80MSU1002120A*AHRI reference: 21635002817.008.10248002.14EPA 3805543
FTMA5B48L0C*AHRI reference: 21635398917.008.10246002.30EPA 3805557
EVM5X60M21A*+ furnace: *80VTL0902120B*AHRI reference: 21635006017.008.10246002.14EPA 3805610
EVM5X60M21A*+ furnace: *80VTL1102122B*AHRI reference: 21635006817.008.10244002.16EPA 3805619
EVD5X61M24A*+ furnace: *96VTN0802120B*AHRI reference: 21635143717.008.50256002.22EPA 3805686
EVD5X60M21A*+ furnace: *80VTL0902120B*AHRI reference: 21635081217.008.10246002.16EPA 3805783
EVD5X60M21A*+ furnace: *80VTL1102122B*AHRI reference: 21635082017.008.10244002.16EPA 3805793
EVD5X60M21A*+WALLCON+ furnace: *95CSU0802120B*AHRI reference: 21635082817.008.00238002.16EPA 3805801
EVD5X61M24A*+ furnace: *97VTN0802120A*AHRI reference: 21635150917.008.00256002.10EPA 3805873
EVD5X61M24A*+ furnace: *97VTN1002120A*AHRI reference: 21635151717.008.00252002.12EPA 3805881
EVM5X60M21A*+WALLCON+ furnace: *96CTN0802120B*AHRI reference: 21635015617.008.00238002.18EPA 3805925
EVM5X60M21A*+WALLCON+ furnace: *97CTN0802120A*AHRI reference: 21635022017.008.00238002.18EPA 3806390
FCMA5B48L0C*+WALLCONAHRI reference: 21635399717.008.00246002.28EPA 3806435
EVD5X61M21A*+ furnace: *80VSL0902120B*AHRI reference: 21635101217.008.50248002.26EPA 3806493
EVM5X48M21A*+ furnace: *80MSU0802120A*AHRI reference: 21634951617.008.10240002.16EPA 3806556
EVM5X48M21A*+WALLCON+ furnace: *80CTL0902120B*AHRI reference: 21634954017.008.00234002.18EPA 3806573
EVM5X48M21A*+WALLCON+ furnace: *80CTL1102120B*AHRI reference: 21634954817.008.00234002.16EPA 3806581
EVD5X48M21A*+ furnace: *80MSU0802120A*AHRI reference: 21635029217.008.10240002.16EPA 3806646
EVD5X48M21A*+WALLCON+ furnace: *80CTL0902120B*AHRI reference: 21635032417.008.00234002.18EPA 3806957
EVD5X48M21A*+WALLCON+ furnace: *80CTL1102120B*AHRI reference: 21635033217.008.00234002.16EPA 3806973

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →