413 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity45,500–50,500BTU/h

Each efficiency range summarizes published EPA records for (C,H,T)5H8T48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 413 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18413 / 413
EER2 · BTU/Wh11.7–13.5413 / 413
HSPF2 · BTU/Wh7.8–8.5413 / 413
Cooling capacity · BTU/h45,500–50,500413 / 413
Heating capacity at 47°F / 8.3°C · BTU/h48,500–52,500413 / 413
Heating capacity at 17°F / −8.3°C · BTU/h29,400–32,400413 / 413
Heating capacity at 5°F / −15°C · BTU/h23,200–26,600413 / 413
COP at 5°F / −15°C2.1–2.34413 / 413
Equipment / loop typeHP - Split System413 / 413
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)413 / 413
Compressor stagingTwo-stage413 / 413
Connected capabilityNo413 / 413

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EVM5X60M21A*+ furnace: *80MSU1002120A*AHRI reference: 21635002817.008.10248002.14EPA 3805543 →
FTMA5B48L0C*AHRI reference: 21635398917.008.10246002.30EPA 3805557 →
EVM5X60M21A*+ furnace: *80VTL0902120B*AHRI reference: 21635006017.008.10246002.14EPA 3805610 →
EVM5X60M21A*+ furnace: *80VTL1102122B*AHRI reference: 21635006817.008.10244002.16EPA 3805619 →
EVD5X61M24A*+ furnace: *96VTN0802120B*AHRI reference: 21635143717.008.50256002.22EPA 3805686 →
EVD5X60M21A*+ furnace: *80VTL0902120B*AHRI reference: 21635081217.008.10246002.16EPA 3805783 →
EVD5X60M21A*+ furnace: *80VTL1102122B*AHRI reference: 21635082017.008.10244002.16EPA 3805793 →
EVD5X60M21A*+WALLCON+ furnace: *95CSU0802120B*AHRI reference: 21635082817.008.00238002.16EPA 3805801 →
EVD5X61M24A*+ furnace: *97VTN0802120A*AHRI reference: 21635150917.008.00256002.10EPA 3805873 →
EVD5X61M24A*+ furnace: *97VTN1002120A*AHRI reference: 21635151717.008.00252002.12EPA 3805881 →
EVM5X60M21A*+WALLCON+ furnace: *96CTN0802120B*AHRI reference: 21635015617.008.00238002.18EPA 3805925 →
EVM5X60M21A*+WALLCON+ furnace: *97CTN0802120A*AHRI reference: 21635022017.008.00238002.18EPA 3806390 →
FCMA5B48L0C*+WALLCONAHRI reference: 21635399717.008.00246002.28EPA 3806435 →
EVD5X61M21A*+ furnace: *80VSL0902120B*AHRI reference: 21635101217.008.50248002.26EPA 3806493 →
EVM5X48M21A*+ furnace: *80MSU0802120A*AHRI reference: 21634951617.008.10240002.16EPA 3806556 →
EVM5X48M21A*+WALLCON+ furnace: *80CTL0902120B*AHRI reference: 21634954017.008.00234002.18EPA 3806573 →
EVM5X48M21A*+WALLCON+ furnace: *80CTL1102120B*AHRI reference: 21634954817.008.00234002.16EPA 3806581 →
EVD5X48M21A*+ furnace: *80MSU0802120A*AHRI reference: 21635029217.008.10240002.16EPA 3806646 →
EVD5X48M21A*+WALLCON+ furnace: *80CTL0902120B*AHRI reference: 21635032417.008.00234002.18EPA 3806957 →
EVD5X48M21A*+WALLCON+ furnace: *80CTL1102120B*AHRI reference: 21635033217.008.00234002.16EPA 3806973 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.